• products
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
Picture
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker
  • ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker

ZN28A-12 ZN28-12 Indoor Vacuum Circuit Breaker

1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln, type D(10-20)ln

Conatct Us

Product Details

● ZN28-12 indoor MV vacuum circuit breaker is high indoor switch equipment of three-phase AC 50Hz, rated voltage 12kV. The product conforms to the GB1984-89 standard, the product structure has two forms: the switch body and the actuator is mounted together or switch body and actuator installed separately. Integrated structure is ZN28-12 basic model; split structure is ZN28A-12 type, suitable for various kinds of fixed type switch cabinet, such as GG-1A (Z), XGNZ-10 (Z) etc..
● It can be equipped with CD17 type DC electromagnetic actuator and CT17, CT19 spring type operating mechanism.

Selection

3.1

Operating conditions

1.  The environment temperature: upper limit +40℃, lower limit -15℃;

2.  Altitude: ≤2000m;

3.  Relative humidity: daily average value is not greater than 95%, monthly average is not greater than 90%;

4.  Earthquake intensity: less than 8 degrees;

5.  No fire, explosion, pollution, chemical corrosion and severe vibration place.

3.2.1

Technical data

Item Unit Parameter
Parameters of voltage, current, life
Rated voltage kV 12
Rated short time power frequency withstand voltage (1min) kV 42
Rated lightning impulse withstand voltage (peak) kV 75
Rated frequency Hz 50
Rated current A 630
1250
630
1250
1250
1600
2000
2500
1600
2000
2500
3150
Rated short-circuit breaking current kA 20 25 31.5 40
Rated short-time withstand current (RMS) kA 20 25 31.5 40
Rated peak withstand current kA 50 63 80 100
Rated short-circuit closing current kA 50 63 80 100
Rated single / back-to-back capacitor bank breaking current A 630/400
Rated short-circuit current duration S 4
Rated short-circuit current breaking times Times 50 30
Rated operating sequence O-t-CO-180s-CO
rated short-circuit breaking
current less than 31.5kA, t=0.3s
rated short-circuit breaking
current 40kA, t=180s
Rated operation voltage ≌ 220/110
Mechanical life Times ≥10000
Mechanical property parameters
Open clearance between contacts mm 11±1
Overtravel mm 4±1
Contact closing bounce time ms ≤2 ≤3
Three-phase, switching synchronism ms ≤2
Average opening speed m/s 0.9~1.3
Average closing speed m/s 0.4~0.8
Opening time (rated voltage) ms ≤60
Closing time (rated voltage) ms ≤100

Overall and mounting dimensions(mm)

3.2

Type H H1 H2 H3 A A1 A2 B B1 B2 B3
ZN28-12/T 2500
3150
-40 780 700 268 371 581 450 390 700 560 275 690
ZN28-12/T2000-31.5 697 677 235 347 550 380 330 634 480 250 620
ZN28-12/T 630
1250
- 20
31.5
697 677 235 347 550 380 330 594 440 230 580

3.3

Rated current 20KA, 25KA, 31.5KA 40kA
Code A B A B
Data 250 610 275 690