Product Overview
Product Details
Data Download
Related Products
Contact Us
YCX8-□ series photovoltaic DC box can be equipped with different components according to different needs of customers, and its combination is diversified to meet different needs of customers. It is used for isolation, overload, short circuit, lightning protection and other protection of photovoltaic DC system to ensure the reliable and safe operation of photovoltaic system. This product is widely used in residential, commercial, and factory photovoltaic power generation systems.
And it is designed and configured in strict accordance with the requirements of "Technical Specifications for Photovoltaic Convergence Equipment" CGC/GF 037:2014.
● Multiple solar photovoltaic arrays can be connected simultaneously, with a maximum of 6 circuits;
● Rated input current of each circuit is 15A (customizable as required);
● The output terminal is equipped with a photovoltaic DC high-voltage lightning protection module that can withstand a maximum lightning current of 40kA;
● High voltage circuit breaker is adopted, with DC rated working voltage up to DC1000, safe and reliable;
● The protection level reaches IP65, meeting the use requirements for outdoor installation.
YCX8 | - | IFS | 2/1 | 15/32 | - | DC500 |
Model | Functions | Input circuit/ Output circuit |
Input current/ Output current |
System Voltage | ||
Photovoltaic box |
I: Isolation | 1/1 2/1 2/2 3/1 3/3 4/1 4/2 4/4 5/1 5/2 6/1 6/2 6/3 6/6 |
15A(Changeable)/ Match as needed |
DC500 DC1000 |
||
IF: Isolation& Fuse | ||||||
DIS:Door lock Isolation& SPD | ||||||
BS:MCB&SPD | ||||||
IFS:Isolation& Fuse&SPD | ||||||
IS:Isolation& SPD | ||||||
FS:Fuse&SPD | ||||||
BFS:MCB&Fuse&SPD |
Note:*The product will be produced according to the company's standard scheme. (To be confirmed with the customer before
production)* if the customer customizes other solutions, please contact us before placing an orde
Model | YCX8-I | YCX8-IF | YCX8-DIS | YCX8-BS | YCX8-IFS | YCX8-IS | YCX8-FS | YCX8-BFS | |
Rated insulation voltage(Ui) | 1500VDC | ||||||||
Input strings | 1、2、3、4、5、6 | ||||||||
Output strings | 1、2、3、4、5、6 | ||||||||
Rated voltage(Ue) | 500VDC、1000VDC | ||||||||
Maximum input current | 1~100A | ||||||||
Maximum output current | 32~100A | ||||||||
Enclosure | |||||||||
Waterproof terminal boxYCX8 | □ | □ | - | □ | □ | □ | □ | □ | |
Plastic distribution box | □ | □ | □ | □ | □ | □ | □ | □ | |
Fully plastic sealed box | □ | □ | □ | □ | □ | □ | □ | □ | |
Configuration | |||||||||
Photovoltaic isolation switch | ■ | ■ | ■ | - | ■ | ■ | ■ | - | |
Photovoltaic fuse | - | ■ | - | - | ■ | - | ■ | ■ | |
Photovoltaic MCB | - | - | - | ■ | - | - | - | ■ | |
Photovoltaic surge protective device | - | - | ■ | ■ | ■ | ■ | - | ■ | |
Anti reflection diode | - | - | - | - | - | - | - | - | |
Monitoring module | - | - | - | - | - | - | - | - | |
Input/output port | Mc4 | □ | □ | □ | □ | □ | □ | □ | □ |
PG | □ | □ | □ | □ | □ | □ | □ | □ | |
Environment | |||||||||
Working temperature | -20℃~+60℃ | ||||||||
Humidity | 0.99 | ||||||||
Altitude | <2000m | ||||||||
Installation | Wall mounting |
■ Standard □ Optional - Non