Photovoltaic fuse YCF8-□ PVS series is applicable to DC distribution lines with rated voltage not exceeding DC1500V, rated current not exceeding 50A and rated short circuit capacity not exceeding 50kA; It is used for line overload and short circuit protection. It is mainly used in energy storage systems and solar photovoltaic combiner boxes as short circuit and overload protection for solar photovoltaic power generation devices, batteries and other semiconductor devices.
Standard: IEC 60269-6 UL248-19

Contact Us

Product Details

Responsive 3D Model
1

eneral

Photovoltaic fuse YCF8-□ PVS series is applicable to DC distribution lines with rated voltage not exceeding DC1500V, rated current not exceeding 50A and rated short circuit capacity not exceeding 50kA; It is used for line overload and short circuit protection. It is mainly used in energy storage systems and solar photovoltaic combiner boxes as short circuit and overload protection for solar photovoltaic power generation devices, batteries and other semiconductor devices.
Standard: IEC 60269-6 UL248-19

Selection

YCF8 - 63 PVS DC1500
Model Shell frame Product type Rated Voltage
Fuse 63 PVS:Photovoltaic DC DC1500V

Technical data

Model YCF8-63PVS
Fuse size(mm) 10 ×85 14 ×85
Rated working voltage Ue(V) DC1500
Rated insulation voltage Ui(V) DC1500
Rated short-circuit breaking capacity (KA) 20
Operating level gPV
Standard IEC60269-6, UL4248-19
Number of poles 1P
Installation method TH-35 Din-rail installation
Operating environment and installation
Working temperature -40℃≤X≤+90℃
Altitude ≤2000m
Humidity When the maximum temperature is+40℃, the relative humidity of the air shall not
exceed 50%, and higher humidity can be allowed at lower temperatures,   For example +90% at 25℃. Special measures shall betaken for occasional condensation due to temperature changes;
Installation environment In a place where there is no explosive medium and the medium is not enough to corrode metal and damage insulation gas and conductive dust.
Pollution degree Level 3
Installation category III

Fuse adapter table

 

Fuse(Base) Fuse
Model Model Current rating Voltage
YCF8-63PVS DC1500 YCF8-1085 2, 3, 4, 5, 6, 8, 10, 15, 16, 20, 25, 30, 32 DC1500
YCF8-1485 30-50
2

Selection

YCF8 - 1085 25A DC1500
Product name Size Rated current Rated Voltage
Fuse link 1085: 10×85(mm) 2-32A DC1500V
1485: 14×85(mm) 40-50A

Technical data

Model YCF8-1085 YCF8-1485
Rated current In(A) 2-32A 40-50A
Fuse size 10×85 14×85
Rated working voltage Ue(V) DC1500
Rated short-circuit breaking capacity (KA) 20
Time constant(ms) 1-3ms
Operating level gPV
Standard IEC60269-6, UL248-19

Test method
The agreed time and current of the fuse "gPV"

Rated current of
the fuse "gPV"
(A)
Agreed time
(h)
Agreed current
Inf If
In≤63 1 1.13In 1.45In
63<In≤160 2
160<In≤400 3
In>400 4

Joule integral table

 

Model Rated current
(A)
Joule integral I²T(A²S)
Pre-arcing Total
YCF8-1085 2 4 8
3 6 11
4 8 14
5 11 22
6 15 30
8 9 35
10 10 98
12 12 120
15 14 170
20 34 400
25 65 550
30 85 680
32 90 720
YCF8-1485 40 125 800
50 155 920