YCW8G-DC DC Frame Isolation Switch
YCW8G-DC DC Frame Isolation Switch
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCW8G-DC DC Frame Isolation Switch
Picture
  • YCW8G-DC DC Frame Isolation Switch
  • YCW8G-DC DC Frame Isolation Switch

YCW8G-DC DC Frame Isolation Switch

The YCW8G-DC DC frame isolation switch is suitable for DC systems with a rated operating voltage of DC1500V and below, and a rated current of 4000A and below. It is used for infrequent switching on and off of circuits, serving the purpose of isolating circuits.

Standards: IEC 60947-2

Contact Us

Product Details

Operating conditions

1. Ambient temperature: -40°C to +70°C, with a 24-hour average not exceeding +35°C.For temperatures above +40°C, derating is required. Refer to Appendix 1.

2. Atmospheric conditions: At an ambient temperature of +40°C, the relative humidity should not exceed 50%. Higher relative humidity is permissible at lower temperatures,e.g., at +25°C, the relative humidity can reach up to 90%. Condensation caused by temperature changes should be addressed with dehumidification or appropriate measures.

3. Corrosion resistance Grade: Salt mist level 2.

4. Pollution degree: Level 3.

5. Altitude: ≤2000m. For altitudes above 2000m, the isolating switch can be customized.

Refer to Appendix 2 .

6. Seismic resistance: Amplitude: 2–9Hz ±1.5mm, constant acceleration: 9–200Hz 5m/s². Excessive vibration may damage internal mechanical components of the operating mechanism, potentially affecting the reliable operation of the isolating switch.

7. Electromagnetic interference: Capable of withstanding overvoltage caused by electromagnetic interference, aging of the distribution system, or environmental disturbances,including radio waves, static discharge, etc.

8. Installation conditions: The vertical tilt should not exceed 5°. It should be installed in locations free of explosion hazards, conductive dust, and substances that could corrode metal or damage insulation.

9. Installation category: Installation category IV for the isolating switch’s main circuit; category III for the control circuit.

10.Protection rating: IP30; IP40 when installed in a cabinet compartment with an additional protective door frame.

Type designation

YCW8G     -2500     DC    /2630A     F     H     DC1500
Product name Shell frame DC Number of poles Rated current Installation
      type
Wiring method Working
voltage
YCW8G 2500  DC 630A F H DC1500
YCW8G 2500
4000
DC 2:2P 630A
800A
1000A
1250A
1600A
2500A
2900A
3200A
3600A
4000A
F:Fixed type H:Horizontal
connection
DC1500

Technical data

Basic parameters Unit Data
Switch model   YCW8G-2500DC YCW8G-4000DC
Conventional free air thermal current(lth) A 2500  4000 
Number of poles P
Rated operational current (le)[A] A 630,800,1000,1250,1600,2000,2500 2500,2900,3200,3600,4000
Rated operational voltage (Ue)[VDC] VDC 1500  1500 
Rated insulation voltage (Ui)[VDC] VDC 1600  2000 
Rated impulse withstand voltage (Uimp)[kV] KV 12  12 
Rated short-time withstand current (Icw)[kA] KA 65KA/1s 100KA/1s,150KA/0.2s,
Rated short-circuit making capacity (Icm)[kA] KA 65  100 
Closing time ms ≤70
Total breaking time ms ≤40
Utilization category   DC-PV2,DC-22A,DC-23A
Mechanical life times 10000 
Electrical life times 500 
Overall dimensions (WDH) mm 286*302.5*400 312*302.5*400

Wiring method

YCW8G DC Frame Isolation Switch Wiring method

Overall and mounting dimensions

 YCW8G-2500DC overall and mounting dimensions

YCW8G-2500DC DC Frame Isolation Switch overall and mounting dimensions
 YCW8G-4500DC overall and mounting dimensions
YCW8G-4000DC Isolation Switch overall and mounting dimensions

Appendix 1: Derating Factor Table

Current range Ambient temperature +40℃ +45°℃ +50℃ +60℃ +65°℃ +70℃
2500A 630A 1.0ln 1.0ln 1.0ln 1.0ln 1.0ln 1.0ln
800A 1.0ln 1.0ln 1.0ln 1.0ln 1.0ln 1.0ln
1250A 1.0ln 1.0ln 1.0ln 1.0ln 1.0ln 1.0ln
1600A 1.0ln 1.0In 1.0ln 1.0ln 1.0ln 0.98In
2000A 1.0ln 1.0ln 1.0ln 1.0ln 1.0ln 0.79ln
2500A 1.0ln 0.95ln 0.89ln 0.85In 0.97In 0.63In
4000A 2500A 1.0ln 1.0In 1.0ln 1.0ln 0.78In 1.0ln
2900A 1.0ln 1.0In 1.0In 1.0ln 1.0ln 0.86ln
3200A 1.0ln 1.0In 1.0In 1.0In 0.97In 0.78In
3600A 1.0ln 1.0In 0.98ln 094In 0.86ln 0.7In
4000A 1.0ln 0.95ln 0.89In 0.85ln 0.78ln 0.63In

Appendix 2: Derating Factor Table

Current range Altitude 2000m 3000m 4000m 5000m
Ambient temperature 3820V 3440V 2730V 2180V
1600A 630A 1.0ln 1.0ln 1.0ln 1.0ln
800A 1.0ln 1.0ln 1.0In 1.0ln
1250A 1.0ln 1.0ln 1.0ln 1.0ln
1600A 1.0ln 0.93In 1.0ln 0.82In
2500A 1600A 1.0ln 1.0ln 0.88In 1.0ln
2000A 1.0ln 1.0ln 1.0ln 1.0ln
2500A 1.0ln 0.93In 0.88In 0.82In

Order specification table

User unit   Order quantity Order date
Basic parameters Frame current □2500 □4000
Rated current □630    □800    □1000
01250        1600  □2000

□2500

□2500   □2900   □3200
□3600 □4000
Instalation method oFixed type
Connection method oHorizontal connection
Accessories □ Undervoltage release □AC220V     □AC380V     □DC110V     □DC220V
□Undervoltage instantaneous release
□Undervoltage delay release 1s □3s □5s
oVoltage loss delay release    □1s □3s □5s
□ Shunt release □AC220V     □AC380V      □DC110V      □DC220V
oShunt release (instantaneous type)
oShunt release (holding type)
□ Closing electromagnet (instantaneous) □AC220V     □AC380V     □DC110V     □DC220V
□ Electric operating mechanism □AC220V     □AC380V     □DC110V       □DC220V
□ Key lock □One lock,one key   □Other
□ Push-button lock  
□ Phase separator  
Auxiliary switches o Four sets of changeover (conventional) □3NO3NC      □4NO4NC      □6NO6NC
Remarks  
Write your message here and send it to us