YCW8- HU Air circuit breaker
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCW8- HU Air circuit breaker
Picture
  • YCW8- HU Air circuit breaker
  • YCW8- HU Air circuit breaker
  • YCW8- HU Air circuit breaker
  • YCW8- HU Air circuit breaker
  • YCW8- HU Air circuit breaker
  • YCW8- HU Air circuit breaker

YCW8- HU Air circuit breaker

General
YCW8-HUseries air circuit breaker(hereinafter called ACB) is suitable for the circuit of AC 50Hz/60Hz with rated service voltage 800V, 1140V and rated service current between 630A and 4000A. It is mainly used to distribute electric energy and protect circuits and electric equipment against over-load, under-voltage, short-circuit and single-phase earthing fault.
With intelligent and selective protection functions, the breaker can improve the reliability of power supply, and avoid unnecessary power failure. The breaker is applicable for power stations, factories.
Standard: IEC 60947-2,IEC 60947-4-1

Contact Us

Product Details

General

YCW8HUseries air circuit breaker(hereinafter called ACB) is suitable for the circuit of AC 50Hz/60Hz with rated service voltage 

800V, 1140V and rated service current between 630A and 4000A. It is mainly used to distribute electric energy and protect 

circuits and electric equipment against over-load,  under-voltage, short-circuit and single-phase earthing fault.

With  intelligent  and  selective  protection  functions,  the  breaker  can  improve  the reliability  of  power  supply,  and  avoid  unnecessary  power  failure.  

The  breaker  is applicable for power stations, factories.

Standard: IEC 60947-2,IEC 60947-4-1

Type designation

YCW8

product name

 

4000

Shell

framecurrent

HU

Breaking Capacity

/

/

3

number of poles

2500A

Rated  current

D

Installation type

H

Connection

M

controller type

 

 

 

 

 

YCW8

 

 

 

 

 

2500(630~2500A)  4000(2000~4000A)

 

 

 

HU  : AC800   /1140V

 

 

 

 

 

/

 

 

 

 

3:3P 4:4P

630

800

1000

1250

1600

2000

2500

2900

3200

3600

3900

4000

 

 

 

 

D: Drawer style

F: Fixed

 

 

 

 

H: Horizontal wiring

V: Vertical wiring

 

 

 

 

M: LED display

3M: LCD display

3H: LCD display with communication

Operating conditions

Item

Description

Ambient temperature

-5℃~+40℃;the average value within 24h shall not exceed +35℃; L type and M type controller can be used under -40℃~+70℃

Altitude

≤2000m

Pollution grade

3

Safety category

Main circuit and undervoltage tripping coil is IV, other auxiliary and control circuit is III

Installation position

Vertically installed, inclination between the mounting plane and the vertical plane should not exceed ±5°

Technical data

Item

Description

Shell current Inm (A)

2500

4000

Rated working current In (A)

630,800,1000

1250,1600,2000,2500

2000, 2500, 2900,

3200, 3600, 3900, 4000

Rated working voltage Ue (V)

800/1140

Rated insulation voltage Ui (V)

1140

Rated impulse withstand voltage Uimp (KV)

12

Power frequency withstand voltage (V) for 1 minute

3500

Number of poles

3P,4P

Rated limit short breaking capacity Icu (KA)

800/1140V

50

50

Rated operating short-circuit breaking capacity Ics (KA)

800/1140V

50

50

Rated short time withstand current for 1s ICW (KA)

800/1140V

50

50

Full power interruption time (without additional delay) (ms)

12~18

Closing time (ms)

≤60

Electrical lifespan

2000

Mechanical life (maintenance free)

10000

Mechanical life (with maintenance)

20000

Basic and optional functions of the controller

Basic function

Optional function

Overload long delay, short circuit short delay, and short circuit instantaneous protection

Signal contact output

Functional testing

MCR and over limit tripping

Fault memory

Load monitoring

Thermal memory

Voltage measurement

Self diagnosis

 

Current measurement

 

Fault status indication and numerical display

 

Earth fault protection

 

Basic function

Optional function

Overload long delay, short circuit short delay, and short circuit instantaneous protection

Current imbalance protection

Functional testing

Signal contact output

Fault memory

MCR and over limit tripping

Thermal memory

Load monitoring

Self diagnosis

power measurement

Current measurement

Power factor measurement

Fault status indication and numerical display

Electric energy measurement

Communication function (3H)

Regional interlocking

Contact wear indicator (3H)

Harmonic measurement

Operation fault protection record (3H)

Voltage protection

Earth fault protection

Voltage measurement

 

 

Controller model

M

3M

3H

Overload long delay protection

 

 

 

Short circuit short time delay protection

 

 

 

Short circuit instantaneous protection

 

 

 

Earth fault protection

 

 

 

Current imbalance protection

 

 

 

Functional testing

 

 

 

Fault memory

 

 

 

Signal contact output

 

 

 

Thermal memory

 

 

 

Self diagnosis

 

 

 

MCU working instructions

 

 

 

Current column display

 

 

 

Current measurement

 

 

 

MCR and over limit tripping

 

 

 

Load monitoring

 

 

 

Fault status indication and numerical display

 

 

 

Voltage measurement

 

 

 

Power factor measurement

 

 

 

power measurement

 

 

 

Electric energy measurement

 

 

 

Communication function

 

 

 

Contact wear indication

 

 

 

Regional interlocking

 

 

 

Harmonic measurement

 

 

 

Voltage protection

 

 

 

Record of operation times

 

 

 

 
 
Accessories

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories of YCW8
 

Shunt release

Shunt release can realize the remote control to break the circuit breaker.

●  rated control power voltage Us(V) AC220V/230V, AC380V/400V, DC220V, DC110V

●  work voltage (0.7~1.1)Us

●  breaking time (50±10)ms

Forbid making the power for longtime to avoid the shunt release being damaged.

 

Closing electromagnet

After the motor finishes the energy storage, closing release can instantly close the circuit breaker.

●  rated control power voltage Us(V) AC220V/230V, AC380V/400V, DC220V, DC110V

●  work voltage (0.85~1.1)Us

●  closing time (55±10)ms

Forbid making the power for longtime to avoid the closing release being damaged.

 

Under-voltage release

Without power supply, under-voltage release can't close. It is classified into instantaneous and time-delay type.

After closing the circuit breaker, under-voltage release can break the circuit breaker when the voltage drops to (70%~35%) Us. The circuit breaker can be closed again when power voltage recovers and exceeds 85%Us.

●  rated control power voltage Us(V) AC220V/230V,AC380V/400V

●  action voltage (0.35~0.7)Us

●  reliable making voltage (0.85~1.1)Us

●  reliable non-making voltage ≤0.35Us

●  delay time: 0.5s,1s,1.5s,3s (YCW3-1600 , non-adjustable);

0.5s, 1s, 3s, 5s(YCW3-2000A, 3200A, 4000A, 6300A, adjustable).

Make sure there is power supply on the under-voltage release before making the circuit breaker.

 

Motor-driven energy-storage mechanism

With the function of motor-driven storing and auto restoring energy after closing the circuit breaker, the mechanism can ensure to close the circuit breaker instantly after breaking the circuit breaker.

●  rated control power voltage Us(V) AC220V/230V,AC380V/400V,DC220V,DC110V

●  work voltage (0.85~1.1)Us

●  power loss 75W(1600A), 85W(2000A),110W(3200A,4000A),150W(6300A)

●  energy-storage time <5s

 

 

Auxiliary contact

 

Standard model: 4NO/4NC

For YCW3-2500,4000: 4NO/4NC, 4NO+4NC, 2NO+6NC, 3NO+3NC.

Ith: AC380V/AC400V 0.75A, DC220V 0.15A, AC220V/AC230V 1.3A.

 

Key lock

The OFF button of the circuit breaker can be locked in the depressed position and the circuit breaker cannot be closed in that case; when the user selects the option, the factory provides locks and keys; 

One breaker is provided with one lock and one key for the lock; two breakers are provided with two locks and one key for the locks; three breakers are provided with three same locks and two same keys for the locks.

 

Note:  It  is  necessary to firstly  press the  OFF  key and turn  it anticlockwise  before pulling out the key for the air circuit breaker with key lock equipped.

"Disconnected" position locking device for the draw-out type

For the “disconnected” position of the draw-out circuit breaker, a lock rod can be pulled out to lock the matter, and the breaker locked will be unable to be turned towards the TEST or CONNECTION position.

 

Padlocks have to be provided by users themselves.

 

Three position locking device for the draw-out

It is the locking device for three positions(disconnected, test, connection) of drawout type.

Three positions of circuit breaker is indicated by the indicator, the driving and the reversing handle which is locked in the exact position, and the lock can be released by the reset button.

 

Door-case

Installed on the door of the distribution cubicle, for sealing the distribution cubicle and making the protection class to IP40(fixed type and draw-out type).

 

 

Phases barrier (optional)

Installed between the bus-bars to increase the creepage distance.

 

 

Controller accessories

External N-pole transformer

In 3P+N system, it is used to measure N-pole current and fitted on the bus-bar by user.

 

 

 

 

Leakage current transformer

1. If the grounding protection is the leakage type, then a rectangular transformer will be needed.

 

 

 

Write your message here and send it to us