Product Overview
Product Details
Data Download
Related Products
General
The YCRS series rapid shutdown device can shut down one ortwo string modules at maximum,with a maximum circuit current of 55A and a maximum circuit voltage of 1500VDC.It is made of PC+ABS material and hasan IP66 protection rating.Multiple interface types areavailable,induding push-through holes,pressure covers,and MC4 terminals.The internalisolation switch is certified byTUVCE.CB.SAA,andthe device is equipped with a waterproof and ventilated valve design to prevent condesation inside the housing.An advanced temperature sensor is used to detect the highest temperature inside the housing in real-time,and theswitch will automatically cutoff when the internal temperature exceeds 70 degreesCelsius.This device is suitablefor residential,industrial,and commercial photovoltaic systems.
Contact Us
The YCRS series rapid shutdown device can shutdown one or two string modules at maximum, with a maximum circuit current of 55A and a maximum circuit voltage of 1500VDC. It is made of PC+ABS material and has an IP66 protection rating. Multiple interface types are available, including push-through holes, pressure covers,and MC4 terminals. The internal isolation switch is certified by TUV.CE.CB.SAA,and the device is equipped with a waterproof and ventilated valve design to prevent condesation inside the housing.An advanced temperature sensor is used to detect the highest temperature inside the housing in real-time, and the switch will automatically cut off when the internal temperature exceeds 70 degrees Celsius. This device is suitable for residential, industrial,and commercial photovoltaic systems.
Why do photovoltaic power generation systems need to be equipped with fast shutdown devices?The use of rapid shutdown devices in photovoltaic (PV) systems has become increasingly important due YCRS Rapid Shutdown Device YCRS Rapid Shutdown Deviceto concerns about safety in recent years. PV system accidents often result in fires, and 80% of these fires are caused by DC voltage arcing. Additionally, because many distributed PV systems are installed in densely populated areas or near industrial facilities, any accidents or failures can lead to significant losses of life and property. Therefore, many countries require that PV systems be equipped with component-level rapid shutdown devices in order to eliminate DC voltage in emergency situations and protect the safety of firefighting and maintenance personnel, as well as to ensure the overall safety of the system. In the event of a fire or other emergency, maintenance personnel can quickly disconnect each component by closing the YCRS device and eliminating the DC voltage, thus protecting the safety of firefighting and maintenance personnel.
YCRS | - | 50 | 2 | MC4 |
Enterprise code |
Rated current |
Wiring mode |
Joint type |
|
Firefighter safety switch |
13:13A 20:20A 25:25A 40:40A 50:50A |
2 4 4B 6 8 10 12 14 16 18 20 |
MC4:MC4 joint /:No |
Note: RP Rapid Shutdown Switch/Panel
Model | YCRS-2/4/4B | YCRS-6/8 | YCRS-10 | YCRS-12~20 Large |
String voltage(VDC) | 300~1500 | 300~1500 | 300~1500 | 300~1500 |
String current A | 9~55 | 9~55 | 9~55 | 9~55 |
Return circuit | 1/2 | 03/4/5 | 03/4/5 | 06/8/10 |
Isolation switch circuit connection method | 2/4/4B | 6/8 | 10 | 12/16/20 |
Working voltage | 100Vac-270Vac | 100Vac-270Vac | 100Vac-270Vac | 100Vac-270Vac |
Rated voltage | 230Vac | 230Vac | 230Vac | 230Vac |
Rated current | 30mA | 30mA | 30mA | 60mA |
Starting (loading) current | 100mA(AVG) | 100mA(AVG) | 100mA(AVG) | 200mA(AVG) |
Action current | 300mA(Max) | 300mA(Max) | 300mA(Max) | 600mA(Max) |
Contact action conditions | 24Vdc-300mA(Max) | 24Vdc-300mA(Max) | 24Vdc-300mA(Max) | 24Vdc-300mA(Max) |
Working temperature | -20℃-+50℃ | -20℃-+50℃ | -20℃-+50℃ | -20℃-+50℃ |
Maximum temperature before automatic shutdown |
+70℃ | +70℃ | +70℃ | +70℃ |
Storage temperature | -40℃-+85℃ | -40℃-+85℃ | -40℃-+85℃ | -40℃-+85℃ |
Protection degree | IP66 | IP66 | IP66 | IP66 |
Overcurrent protection | II | II | II | II |
Authentication | CE | CE | CE | CE |
Standard | EN60947-1&3 | EN60947-1&3 | EN60947-1&3 | EN60947-1&3 |
Mechanical life | 10000 | 10000 | 10000 | 10000 |
Load operands(PV1) | >1500 | >1500 | >1500 | >1500 |
Data of ERS refer to built-in DC isolators. Data according to IEC60947-3(ed.3.2):2015,UL508i.Utilization category DC-PV1. |
Pole number | Circuit | Model | ||||
600V | 800V | 1000V | 1200V | 1500V | |||
32 | 26 | 13 | 10 | 5 | 2 | 1 | YCRS-13 2 |
40 | 30 | 20 | 12 | 6 | 2 | 1 | YCRS-20 2 |
55 | 40 | 25 | 15 | 8 | 2 | 1 | YCRS-25 2 |
/ | 50 | 40 | 30 | 20 | 2 | 1 | YCRS-40 2 |
/ | 55 | 50 | 40 | 30 | 2 | 1 | YCRS-50 2 |
32 | 26 | 13 | 10 | 5 | 4 | 2 | YCRS-13 4 |
40 | 30 | 20 | 12 | 6 | 4 | 2 | YCRS-20 4 |
55 | 40 | 25 | 15 | 8 | 4 | 2 | YCRS-25 4 |
/ | 50 | 40 | 30 | 20 | 4 | 2 | YCRS-40 4 |
/ | 55 | 50 | 40 | 30 | 4 | 2 | YCRS-50 4 |
32 | 26 | 13 | 10 | 5 | 4 | 1 | YCRS-13 4B |
40 | 40 | 40 | 30 | 20 | 4 | 1 | YCRS-20 4B |
/ | / | 55 | 40 | 30 | 4 | 1 | YCRS-25 4B |
/ | / | / | / | 45 | 4 | 1 | YCRS-40 4B |
/ | / | / | / | 50 | 4 | 1 | YCRS-50 4B |
32 | 26 | 13 | 10 | 5 | 6 | 3 | YCRS-13 6 |
40 | 30 | 20 | 12 | 6 | 6 | 3 | YCRS-20 6 |
55 | 45 | 25 | 15 | 8 | 6 | 3 | YCRS-25 6 |
/ | 50 | 40 | 30 | 20 | 6 | 3 | YCRS-40 6 |
/ | 55 | 50 | 40 | 30 | 6 | 3 | YCRS-50 6 |
32 | 26 | 13 | 10 | 5 | 8 | 4 | YCRS-13 8 |
40 | 30 | 20 | 12 | 6 | 8 | 4 | YCRS-20 8 |
55 | 40 | 25 | 15 | 8 | 8 | 4 | YCRS-25 8 |
/ | 50 | 40 | 30 | 20 | 8 | 4 | YCRS-40 8 |
/ | 55 | 50 | 40 | 30 | 8 | 4 | YCRS-50 8 |
32 | 26 | 13 | 10 | 5 | 10 | 5 | YCRS-13 10 |
40 | 30 | 20 | 12 | 6 | 10 | 5 | YCRS-20 10 |
55 | 40 | 25 | 15 | 8 | 10 | 5 | YCRS-25 10 |
/ | 50 | 40 | 30 | 20 | 10 | 5 | YCRS-40 10 |
/ | 55 | 50 | 40 | 30 | 10 | 5 | YCRS-50 10 |
32 | 26 | 13 | 10 | 5 | 12 | 6 | YCRS-13 12 |
40 | 30 | 20 | 12 | 6 | 12 | 6 | YCRS-20 12 |
55 | 40 | 25 | 15 | 8 | 12 | 6 | YCRS-25 12 |
/ | 50 | 40 | 30 | 20 | 12 | 6 | YCRS-40 12 |
/ | 55 | 50 | 40 | 30 | 12 | 6 | YCRS-50 12 |
32 | 26 | 13 | 10 | 5 | 14 | 6 | YCRS-13 14 |
40 | 30 | 20 | 12 | 6 | 14 | 6 | YCRS-20 14 |
55 | 40 | 25 | 15 | 8 | 14 | 6 | YCRS-25 14 |
/ | 50 | 40 | 30 | 20 | 14 | 6 | YCRS-40 14 |
/ | 55 | 50 | 40 | 30 | 14 | 6 | YCRS-50 14 |
Note: RP Rapid Shutdown Switch/Panel
Data of ERS refer to built-in DC isolators. Data according to IEC60947-3(ed.3.2):2015,UL508i.Utilization category DC-PV1. |
Pole number | Circuit | Model | ||||
600V | 800V | 1000V | 1200V | 1500V | |||
32 | 26 | 13 | 10 | 5 | 16 | 8 | YCRS-13 16 |
40 | 30 | 20 | 12 | 6 | 16 | 8 | YCRS-20 16 |
55 | 40 | 25 | 15 | 8 | 16 | 8 | YCRS-25 16 |
/ | 50 | 40 | 30 | 20 | 16 | 8 | YCRS-40 16 |
/ | 55 | 50 | 40 | 30 | 16 | 8 | YCRS-50 16 |
32 | 26 | 13 | 10 | 5 | 18 | 8 | YCRS-13 18 |
40 | 30 | 20 | 12 | 6 | 18 | 8 | YCRS-20 18 |
55 | 40 | 25 | 15 | 8 | 18 | 8 | YCRS-25 18 |
/ | 50 | 40 | 30 | 20 | 18 | 8 | YCRS-40 18 |
/ | 55 | 50 | 40 | 30 | 18 | 8 | YCRS-50 18 |
32 | 26 | 13 | 10 | 5 | 20 | 10 | YCRS-13 20 |
40 | 30 | 20 | 12 | 6 | 20 | 10 | YCRS-20 20 |
55 | 40 | 25 | 15 | 8 | 20 | 10 | YCRS-25 20 |
/ | 50 | 40 | 30 | 20 | 20 | 10 | YCRS-40 20 |
/ | 55 | 50 | 40 | 30 | 20 | 10 | YCRS-50 20 |
Note: RP Rapid Shutdown Switch/Panel
YCRS-2/4P/4B series
YCRS-2/4/4B series
YCRS-10 series
YCRS-12~20 series
2P/4P
6P
8P
10P
12~20P
Note: the fire safety switch cannot be installed in the place with direct sunlight, and the sun visor is recommended.