YCQR2 Soft Starter
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCQR2 Soft Starter
Picture
  • YCQR2 Soft Starter
  • YCQR2 Soft Starter
  • YCQR2 Soft Starter
  • YCQR2 Soft Starter
  • YCQR2 Soft Starter
  • YCQR2 Soft Starter
  • YCQR2 Soft Starter
  • YCQR2 Soft Starter

YCQR2 Soft Starter

AC squirrel-cage type asynchronous electric motor is a popular electric apparatus. By applying intelligent, the apparatus completes stable load making capacity and
reduces impact strength to electrical network; it can work with stable and reliable performance. YCQR2 Model soft starter completes Human-machine interface.
Applied to a scope of 5.5~600KW in thermal power plant, hydraulic power plant, metallurgy, chemical industry, architecture , cement plant ,mining industry as well as environmental protection projects. It’s the ideal replacer of Y-△ Starter, reactor starter, auto-transformer starter etc.

Contact Us

Product Details

Functions of YCQR2 Soft Starter

1. Double Single-chip machine automatic digital control;
2. Parameters like starting torsion current, voltage, and time to be set according to different load, to obtain optimal torque control feature.
3. Smooth and gradual starting process, to reduce the impact strength of electric network, vibration and noise of apparatus, to lengthen lifetime of mechanical driver and to improve working environment.
4. Starting current is adjustable as per load, to reduce starting consumption and to make optimal torque with smallest current.
5. Soft stop function – make long lifetime of electric contacts, meet mechanical requirements under various occasions.
6. Over-current protection, overload protection and thermal protection, out- of–phase protection.
7. Extrocontrol interface to facilitate multi-functions: digital delayed start, transient stop control input, start output of time delay relay, fault relay output.
8. No special requirements on the phase sequence to input power.
9. Free stop and soft stop, soft stop time is adjustable.
10. Complete digital control and extrocontrol
11. Standard 485 interface
12. Output 0-20MA analog current
13. Innovative structure, small volume, stable performance, easy installation and operation.
14. Harvard type single-chip machine has strong anti-interruption capacity to prevent the control system from severe electric interruption.

Technical data

Item No. YCQR2
Electric motor power(400v.h)/kw 5.5-600kw
Rated working current Ie/A 10-1200
Rated working voltage / V 380V±15%
Frequency /Hz 50Hz
Continuous working current /A 115% Ie
Rated control voltage/V AC 220V-240V/50Hz
Ambient temperature /℃ 30℃/55℃

Function code table and parameter description

Function Set Range Factory Value Illumination
Code Name
0 Start Voltage 30-80% 30%     Voltage mode effective
1 Rising Time 0-60S 10S     Voltage mode effective
2 Soft Stop Time 0-60S 2S     Stop freely when set as 0
3 Start Delay 0-240S 0S     Two lines way effective
4 Limiting Start Current 150-500% 250%     Limiting current mode effective
5 Interlock Delay 0-240S 0S
6 Transient Stop Set 00-1 0     0:yes         1:no
7 Restart After Transient Stop 00-1 0     0:yes         1:no
8 Control Mode 00-1 1     0:limiting current    1:voltage
9 Control Way 1-6 1     1:keyboard  2:outer control
3:keyboard+outer control
4:PC  5:PC+keyboard
6:PC+outer control
A 0-20mA 00-1 0     0:full scale(20mA)corresponding to 400%
1:full scale(20mA)corresponding to 130%
B Display Mode 0-132 0     0:by percent of rated voltage
XXX:actual rated power value
C Local Address 1-30 0     For serial-port communication
D Set Parameter Modification 00-1 0     0:yes         1:no
E Overload Multiple Set 50-200% 150%
F Out-of-phase Protection 00-1 0     0:yes         1:no
EY Modification Set Protection The data should not be modified in this condition
-A Start And Rising Condition 1.displaying current value XXXA or percent of rate value.
2.Delay start time displays time EOTTT
-A Operation Condition
-A Soft Stop Condition

Note:Values XO-9

Even if using the voltage mode,the limiting current is still effective,and its value is 400%.

product-description2

YCQ2R 55KW Type

Model Power
(KW)
     Rated Current
(A)
Outline Size(mm) Installing Size(mm) Installing Hole
Dimension
A B C E F
YCQR2 5. 5-22 10-40 265 154 165 219 140 Φ6
YCQR2 30 54 265 154 165 219 140 Φ6
YCQR2 37 68 265 154 165 219 140 Φ6
YCQR2 45 80 265 154 165 219 140 Φ6
YCQR2 55 100 265 154 165 219 140 Φ6
C-电动机控制与保护 变频器软启动系列.cdr
Model Power
(KW)
Rated Current
(A)
Outline Size(mm) Installing Size(mm) Installing Hole
Dimension
A B C E F
YCQR2 75 135 531 260 204 380 230 Φ8
YCQR2 90 160 531 260 204 380 230 Φ8
YCQR2 115 200 531 260 204 380 230 Φ8
YCQR2 132 250 531 260 204 380 230 Φ8
YCQR2 160 300 531 260 204 380 230 Φ8
YCQR2 200 360 564 290 204 260 260 Φ8
YCQR2 250 450 564 290 204 260 260 Φ8
YCQR2 320 560 564 290 204 260 260 Φ8
YCQR2 400 800 600 350 220 480 320 Φ8
YCQR2 500 1000 600 350 220 480 320 Φ8
YCQR2 600 1200 600 350 220 480 320 Φ8
Write your message here and send it to us