• products
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCQJ7 Motor Controller
Picture
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller
  • YCQJ7 Motor Controller

YCQJ7 Motor Controller

1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln, type D(10-20)ln

Conatct Us

Product Details

1. General

YCQJ7 series motor controller (hereinafter referred to as controller) is mainly used in circuits with a frequency of AC 50Hz (or 60Hz), a rated operational voltage of up to 380V and a rated control power of up to  18.5kW (current up to 38A) to control the direct start and stop of water pumps ormotors, provide motors with  overload and phase failure protection, and realize automatic liquid level control for civil water towers and reservoirs.This  product is not applicable to the liquid level control of low-conductivity liquids, such as oil, purified water,inflammable and  explosive chemical liquids and high-density sewage.

Standards:lEC 60947-4-1.

3. Operating conditions

3.1 Altitude: the altitude of the mounting location should not exceed 2000m;

3.2 Ambient temperature: -5℃~+40℃, and the average temperature in 24h should not exceed +35℃;

3.3 Atmospheric conditions: The relative air humidity at the mounting location should not exceed 50% at the maximum temperature of +40℃ . The relative humidity may be higher at lower temperatures.Special measures should be taken if condensation occurs on the product occasionally due to temperature variation;

3.4 Pollution degree: 3;

3.5 Installation category: Ⅲ;

3.6 In places where there is no significant vibration or impact;

3.7 In non-explosive media that do not contain a sufficient amount of gas or dust to cause metal corrosion or insulation failure; 3.8 In places where rain and snow protection is provided;

3.9 The inclination from the vertical plane should not exceed 5° .

4. Technical data

4.1 Main data and technical characteristics

Type Conventionalheatingcurrent (A) Max. rated power (kW) Model of matching AC contactor Model of matching motor protector Setting currentrange (A) Number of turns of protector (turn)
AC-3
380V 220V
YCQJ7  0.72A ~2.4A 2.412

 

16

 

25

1.15.5

 

7.5

 

11

0.553

 

4

 

5.5

CJX2s-09CJX2s-12

 

CJX2s-18

 

CJX2s-25

JD-8/0.5A~5AJD-8/2A  20A

 

JD-8/2A ~20A

 

JD-8/20A ~80A

0.72~2.43.5~11

 

10~16

 

20~25

51

 

1

 

1

YCQJ7-W  0.72A ~2.4A YCQJ7  3.5A ~11A
YCQJ7-W 3.5A ~11A YCQJ7  10A ~16A
YCQJ7-W 10A ~16A YCQJ7  20A ~25A
YCQJ7-W 20A ~25A
YCQJ7  30A ~38A 38 18.5 9 CJX2s-38 JD-8/20A ~80A 30~38 1
YCQJ7-W 30A ~38A

4.2 Rated control supply voltage Us: AC220V, AC380V.

4.3 Degree of protection of enclosure: IP55.

4.4 Protection characteristics of the controller.

4.4.1 Phase failure protection characteristics of the controller: In case of failure of any phase of the three-phase main circuit passing through   the center hole of the motor comprehensive protector in the controller, the motor comprehensive protector operates for a period of 5s.

4.4.2 Overload protection characteristics of the controller under balanced three-phase load.

No. Setting Current multiple Operation time Starting conditions
1 1.05 No operation within 2h Cold state start
2 1.2 Operation within 2h Start after No.1
3 1.5 Tripping class 30 ≤12min

Start after applying a 1.0 times setting current for 2h

4 7.2 Tripping class 30 9s<Tp≤30s Cold state start

4.5 Down-lead distance of liquid level control electrode: 200m max.

4.6 Mounting type: installation type.

5. Features

The controller consists of a CJX2s series Ac contactor, a JD-8 series motor comprehensive protector and an YCL8 liquid levelrelay in a protective enclosure and is divided into two types, with liquid level relay and without iquid level relay. Products with iquid levelrelay are used to control the start  and stop and automatic pumping and drainage of water pumps and provide and stop and automatic pumping and drainage of water pumps and     provide overload and phase failureprotection. Products without liquid level relay are used to control the start and stop of motors and provide overload  and phase failureprotection.

Setting of the motor comprehensive protector in the controller is required before it is connected and put into use.

Write your message here and send it to us