YCQ9Ms Automatic transfer switch
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCQ9Ms Automatic transfer switch
Picture
Video
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
  • YCQ9Ms Automatic transfer switch
YCQ9Ms Automatic transfer switch Featured Image

YCQ9Ms Automatic transfer switch

General

YCQ9Ms series dual power automatic transfer switch is suitable for power supply system with AC 50/60Hz, rated working voltage AC400V, rated working current 800A and below.
It is possible to select and switch between two power sources according to requirements, ensuring uninterrupted operation of key power sources. When one power supply has overvoltage, undervoltage or phase loss, it will automatically
switch to another power supply or start the generator.
Built-in RS485 communication interface, communication protocol MODBUS-RTU,  realize real-time data upload, remote data configuration and status monitoring, as well as remote control, telemetry, remote control and remote adjustment functions.
Mainly used in hospitals, shopping malls, banks, hotels, high-rise buildings, fire protection and other places that do not allow long-term power outages with uninterrupted power supply required.
1. Can work in the environment of -5°C~40°C
2. The altitude of the installation site does not exceed 2000m
3. When the highest temperature is +40°C, the relative humidity of the air should not
exceed 50%
4. Higher humidity is allowed at lower temperature, 20°C~90%
Standard: IEC 60947-6-1

Contact Us

Product Details

Responsive 3D Model

YCQ9Ms-125(45°)

General

YCQ9Ms series dual power automatic transfer switch is suitable for power supply

system with AC 50/60Hz, rated working voltage AC400V, rated working current 800A

and below.

It is possible to select and switch between two power sources according to

requirements, ensuring uninterrupted operation of key power sources. When one

power supply has overvoltage, undervoltage or phase loss, it will automatically

switch to another power supply or start the generator.

Built-in RS485 communication interface, communication protocol MODBUS-RTU,

realize real-time data upload, remote data configuration and status monitoring, as

well as remote control, telemetry, remote control and remote adjustment functions.

Mainly used in hospitals, shopping malls, banks, hotels, high-rise buildings, fire

protection and other places that do not allow long-term power outages with

uninterrupted power supply required.

1. Can work in the environment of -5°C~40°C

2. The altitude of the installation site does not exceed 2000m

3. When the highest temperature is +40°C, the relative humidity of the air should not

exceed 50%

4. Higher humidity is allowed at lower temperature, 20°C~90%

Standard: IEC 60947-6-1

Selection

YCQ9Ms 125 M 3 100A W2
Product name hell frame grade Breaking capacity Number of poles Rated current Controller code
 

 

 

 

YCQ9Ms:   Dual power automatic

transfer switch

63: (10-63A)  

 

 

 

M:

Standard

type

 

 

 

 

 

3:3P 4:4P

 

10、16、25、

32、40、

50、63、

80、100、

125、140、

160、180、

200、225、

250、315、

400、500、

630、800、

 

Default:LED Y: LCD

W2:

Split LED display

W3:

Split LED display

125: (16-125A)
250: (100-250A)
400: (250-400A)
630: (400-630A)
800: (630-800A)

Working conditions

1. Can work in the environment of -5°C~40°C

 

2. The altitude of the installation site does not exceed 2000m

 

3. When the highest temperature is +40°C, the relative humidity of the air should not exceed 50%

 

4. Higher humidity is allowed at lower temperature, 20°C~90%

Technical data

Type YCQ9Ms
Shell frame 63 125 250 400 630 800
Rated working current In(A) 10, 16, 20, 25,32, 40, 50, 63 16, 20, 25,32, 40, 50, 63,80, 100, 125 100, 125, 140,160, 180, 200,225, 250 250, 315, 350,400 400, 500, 630 630, 800
Number of poles 3, 4
Electrical class Class CB
Use category AC33iB
Rated working voltage Ue(V) AC380, 400
Rated insulation voltage Ui(V) AC690 AC800
Rated impulse withstand voltage Uimp(KV) 8
Rated short-circuit breaking capacity Icn(KA) 15 25 25 35 35 35
Electrical life 1000 1000 500
Mechanical life 5000 3000 2500
Rated working system Uninterrupt working system
Overvoltage transfer setpoint AC230V-AC300V
Undervoltage transfer setpoint AC150V~AC210V
Contact switch time <4s
Disconnection delay 1s-240s continuously adjustable
Shutdown delay 1s-240s continuously adjustable

Serial number definition
1. Handle 7. Alternative power input and power sampling line
2. Nameplate 8. Controller display
3. Main contact position indication Normal power 9. Controller control button
OFF-OFF 10. Fixed screw holes
Alternative power 11. Alternative power load side
4. Trademark 12. Power indication, closing indication, fault indication output terminal
5. Normal power input and power sampling line 13. Normal power load side
6. Signal terminal: Fire voltage input, generator start signal output 14. Enclosure grounding terminal

YCQ9Ms-125(45°)

Function Introduction

Function Full-function type
Manual mode
Automatic mode
Motor protection function
Main contact working position ( performing circuit breaker)
Normal power supply closed
Reserve power supply closed
Double break
Automatic control
Monitoring normal power supply
Monitoring reserve power supply
Self-throwing and self-reset
Self-throwing and non self-reset
Reserve for each other
Power grid-power grid
Power grid-power generation
Phase failure instantaneous protection
Under-voltage protection 150-210V adjustable
Over-voltage protection 230-300V adjustable
Fire control function
Changeover time delay0-240s continuously adjustable
Returning time delay0-240s continuously adjustable
Frequency display
Communication function optional
Indication
N on/R on/double break indication
Normal power supply indication
Reserve power supply indication
Fault tripping indication
Parameter setting indication
Voltage realtime indication
Normal three phase voltage protection three phase
Reserve three phase voltage protection three phase

Controller Y type Controller W2 type Controller W3 type Controller
Working power supply AC160-250V 50/60Hz DC12V (Provided by the inside OF y TYPE CONTROLLER)
Installation Integral type Split type
Position 3 Positions
Mode of operation Auto, manual and electro-manual operation
Voltage monitoring function 3 phase over-voltage, under-voltage and phase loss monitoring
Frequency monitoring function Frequency monitoring
Generator control A set of 3A relay dry contact
Fire linkage control Passive contact input, with a set of normally open passive signal feedback contact
Mode of conversion According to users requirement could set at A uto Can set at Auto transfer and auto recover,Auto transfer and non-auto recovery or utility generator type mode according to user's requirement.
Display LED display LED display
Conversion time delay 0.5s-60s continuously adjustable
Return time delay 0.5s-60s continuously adjustable
Model Match circuit breaker Pole Rated short circuitmaking capacity(Icm) Rated short circuitbreaking capacity(Icn) Rated currentof circuit breaker(A)10 , 16,  20, 3240 , 50, 63 Rated insulationvoltage(V) 690
YCQ9Ms-63 YCM1-63 3 31.5 15
4 31.5 15
YCQ9Ms-125 YCM1-125 3 52.5 25 16, 20, 32 , 40 ,50, 63 , 80 , 100, 125 690
4 52.5 25
YCQ9Ms-250 YCM1-250 3 52.5 25 125, 160, 180,200,  225, 250 690
4 52.5 25
YCQ9Ms-400 YCM1-400 3 73.5 35 250, 315, 350, 400 690
4 73.5 35
YCQ9Ms-630 YCM1-630 3 73.5 35 500, 630 690
4 73.5 35
YCQ9Ms-800 YCM1-800 3 73.5 35 700, 800 800
4 73.5 35

Switching device installation: After fixing the switching device, according to the rated current to choose the appropriate wires to wire.

Note: The phase sequence of main power and emergency power must be consistent.

Split type controller installation:

Use 2 strutting pieces to fix the split type controller on the panel.

Please check if the controller has been plugged into switching device and fastening screw. Please check whether each electric contact part is reliable and the fuse if good.

If user wants to withstand voltage test, please remove the controller first. Otherwise the controller will be broken down. For the 3 pole switch, user needs to connect main power neutral line to terminal N1 port.

Connect emergency power neutral line to

terminal N2 port. Neutral line must be reliable and don't connect wrong so that ATS could proper work.

For the 4 pole switch, main and emergency power neutral line must be connected to the corresponding circuit breaker N pole. In addition,switching device should ground connection at the grounding mark.

User could connect indicator light to the terminal for observation. Refer to the wiring diagram below.

Note:
This diagram applies to three-phase four-wire. When using three-phase three-wire system, the neutral line of main power connects to
terminal N1 port,neutral line of emergency power connects to terminal N2 port.
HD main power indication AC220V(User-provided).
TD main power indication AC220V(User-provided).

Overall and mounting dimensions(mm)

Dimensions Specification A D B C H1 H2
3P 4P 3P 4P
YCQ9Ms-63 380 405 250 340 365 230 <160 25
YCQ9Ms-125 405 435 250 365 395 230 <170 25
YCQ9Ms-250 450 480 250 410 440 230 <190 25
YCQ9Ms-400 570 620 330 510 560 300 <200 25
YCQ9Ms-630 680 740 330 620 680 300 <250 25
YCQ9Ms-800 750 820 330 690 760 300 <250 25