YCM8-HU Photovoltaic AC MCCB
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCM8-HU Photovoltaic AC MCCB
Picture
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB
  • YCM8-HU Photovoltaic AC MCCB

YCM8-HU Photovoltaic AC MCCB

General
YCM8-HU series AC molded case circuit breaker is suitable for AC grid circuits with rated voltage up to AC1140V and rated current of 800A.
The circuit breaker has the functions of overload long-time delay protection and short-circuit instantaneous protection, and is used to distribute electric energy and protect lines and power supply equipment from overload, short circuit and other faults.

Contact Us

Product Details

General
YCM8-HU series AC molded case circuit breaker is suitable for AC grid circuits with rated voltage up to AC1140V and rated current of 800A.
The circuit breaker has the functions of overload long-time delay protection and short-circuit instantaneous protection, and is used to distribute electric energy and protect lines and power supply equipment from overload, short circuit and other faults.
Features
Ultra-wide breaking capacity:
rated working voltage up to AC1140V and rated current up to 800A. Under AC800V working conditions, Icu=Ics=36.5KA, ensuring reliable short-circuit protection.
 
Ultra-long arc-extinguishing chamber: the arc-extinguishing chamber has been improved as a whole, with more arc extinguishing plates, greatly improving the product's breaking characteristics.
 
Application of narrow-slot arc-extinguishing technology:advanced current-limiting and narrow-slot arc-extinguishing technology is applied,which enables the high voltage and high short-circuit current to be cut off very quickly, facilitating the extinguishing of the arc in the shortest possible time, effectively limiting the energy and current peak, and greatly reducing damage to cables and equipment caused by short-circuit currents.
Selection
YCM8   250  S HU / 125A AC800
Model   Shell frame
current
Breaking
capacity
Product
type
/ Number
of poles
Rated
current
Rated
voltage
YCM8   250(63~250)
320(250~320)
400(225~400)
630(500~630)
800(700~800)
S:Standard breaking
N:Higher breaking
HU:
AC high
voltage
/  63,80,100,125
 140,160,180
 200,225,250
 280,315,320
 350,400,500
 630,700,800
AC800
AC1140
Accessory selection rules
YCM8   MX AC230V
Model   Accessories Adapter
shell frame
Accessory
voltage
YCM8    OF:Auxiliary contact
MX:Shunt release
SD:Alarm module
Z:Manual operation mechanism
P:Electric operating mechanism
TS2:Terminal shield 2P
TS3:Terminal shield 3P
1:250/320
2:400/630/800
  MX:
  AC110V
  AC230V
  AC400V
  DC24V
P:
AC400V
AC230V
DC220V

Technical data

Model

YCM8- 250HU

YCM8- 320HU

YCM8- 400HU

 

 

 

 

Appearance

 

 

 

 

 

Shell frame current Inm(A)

250

320

400

Number of poles of products

       

 

3

AC working voltage(V)

415

690

800

1140

415

690

800

1140

415

690

800

1140

Rated insulation voltageUi(V)

AC1150

AC1150

AC1150

Rated impulse withstand voltage Uimp(KV)

8

8

12

 

Rated current In(A)

63, 80, 100, 125,

140, 160, 180,

200, 225, 250

 

280, 315, 320

225, 250, 315,

350, 400

 

Ultimate short-circuit

breaking capacity Icu (kA)

S

85

50

36.5

10

85

50

36.5

10

85

50

36.5

10

N

/

/

100

60

50

15

Running short-circuit breaking capacity Ics(kA)

Ics=100%Icu

Wiring method

Up in and down out, down in and up out,    Down in and up out, up in and down out(3P)

Isolation function

Yes

Tripping type

Thermal-magnetic type

Electrical life(time)

3000

3000

2000

3000

3000

2000

1000

1000

700

Mechanical life(time)

20000

20000

10000

Standard

IEC/EN60947-2

Attached accessories

Shunt、Alarm、Auxiliary、Manual operation、Electric operation

Certifications

CE

Overall

dimension (mm)

 

 

 

 

W    

 

 

 

 

D

 

Width(W)

107

107

182

Height(H)

180

180

250

Depth(D)

126

126

165

Note: ① 2P connection in series, ② 3P connection in series

 

Technical data

Model

YCM8-630HU

YCM8-800HU

 

 

 

 

Appearance

 

 

Shell frame current Inm(A)

630

800

Number of poles of products

3

3

AC working voltage(V)

415

690

800

1140

415

690

800

1140

Rated insulation voltageUi(V)

AC1150

AC1150

Rated impulse withstand voltage Uimp(KV)

12

12

 

Rated current In(A)

 

500, 630

 

630,700, 800

 

Ultimate short-circuit

breaking capacity Icu (kA)

S

85

50

36.5

10

85

50

36.5

10

N

100

60

50

15

100

60

50

15

Running short-circuit breaking capacity Ics(kA)

Ics=100%Icu

Wiring method

Up in and down out, down in and up out,    Down in and up out, up in and down out(3P)

Isolation function

Yes

Tripping type

Thermal-magnetic type

Electrical life(time)

1000

1000

1000

700

1000

1000

1000

700

Mechanical life(time)

5000

5000

Standard

IEC/EN60947-2

Attached accessories

Shunt、Alarm、Auxiliary、Manual operation、Electric operation

Certifications

CE

Overall

dimension (mm)

 

 

 

 

W    

 

 

 

 

D

 

Width(W)

182

182

Height(H)

250

250

Depth(D)

165

165

Accessories

 

Accessory code

Accessory name

250/320HU

400/630/800HU

SD

Alarm contact

 

 

 

 

 

 

MX

Shunt release

 

 

 

 

 

 

OF

Auxiliary contact(1NO1NC)

 

 

OF+OF

Auxiliary contact(2NO2NC)

 

 

 

 

 

 

MX+OF

Shunt release+ Auxiliary contact(1NO1NC)

 

 

 

 

 

 

OF+OF

2 sets of auxiliary contacts(2NO2NC)

 

 

MX+SD

Shunt release + Alarm contact

 

 

 

 

 

 

OF+SD

Auxiliary contact + Alarm contact

 

 

 

 

 

 

MX+OF+SD

Shunt release Auxiliary contact(1NO1NC)+ Alarm contact

 

 

OF+OF+SD

2 sets of auxiliary contacts(2NO2NC)+Alarm contact

 

 

 

 

Auxiliary contact

Auxiliary contact current parameters

Rated current of shell frame grade

Agreed heating current Ith

The rated working current at AC 400V

Inm<320

3A

0.30A

Inm>400

6A

0.40A

Auxiliary contact and its combination

 

 

When the circuit breaker is in the "off" position

F12 

F14                       F22                       

F24                       

 

 

F11

F21

 

F12 F14

 

 

 

F11

 

 

When the circuit breaker is in the "on" position

F12 F14

 

F11

F22 F24

 

F21

F12 F14

 

 

F11

Alarm contact

Alarm contact and its combination

Alarm contact Ue=220V, Ith=3A

 

When the circuit breaker is   in the "off"and "on"position

B14 B14

 

 

B11

When the circuit breaker is in the "free trip" position

 

B14 B12

 

 

 

B11

Shunt release

Generally installed in the Phase A of the circuit breaker,  when the rated control power voltage is between 70% - 110%, the shunt releaseshall make the circuit breaker trip reliably under all operating conditions.

Control voltage: conventional: AC 50Hz, 110V, 230V, 400V, DC 24V.

Note: when the power supply of the control circuit is DC24V, the following figure is recommended for the design of the shunt control circuit.

KA: DC24V intermediate relay, contact current capacity is 1A

K: the microswitch in series with the coil inside the release aid is a normally closed contact. When the circuit breaker is disconnected, the contact will automatically disconnect and close when it is closed.

Wiring diagram

Installation method and overall dimension of external accessories

Model and specification of rotating operating handle mechanism

 

Model

Installation dimension(mm)

Central value of the operating handle relative to the

circuit breaker(mm)

A

B

H

D

YCM8-250/320HU

157

35

55

50-150

0

YCM8-400/630/800HU

224

48

78

50-150

±5

Schematic diagram of hole opening of rotating operating handle

Overall and mounting dimension of external accessories

Model and specification of rotating operating handle mechanism

 

Model

H

B

B1

A

A1

D

YCM8-250/320HU

188.5

116

126

90

35

4.2

YCM8-400/630/800HU

244

176

194

130

48

6.5

 

 

Model

 

L

A

 

B

 

C

E

Without zero arcing cover

With zero   arcing cover

Without zero arcing cover

With zero   arcing cover

YCM8-250HU

40

100

165

40

40

100

165

YCM8-320HU

40

100

165

40

40

100

165

YCM8-400HU

40

100

165

40

40

100

165

YCM8-630HU

40

100

165

40

40

100

165

YCM8-800HU

40

100

165

40

40

100

165

 

 