Product Overview
Product Details
Data Download
Related Products
Contact Us
Selection | ||||||||||
YCM8 | 250 | S | HU | / | 3 | 125A | AC800 | |||
Model | Shell frame current |
Breaking capacity |
Product type |
/ | Number of poles |
Rated current |
Rated voltage |
|||
YCM8 | 250(63~250) 320(250~320) 400(225~400) 630(500~630) 800(700~800) |
S:Standard breaking N:Higher breaking |
HU: AC high voltage |
/ | 3 | 63,80,100,125 140,160,180 200,225,250 280,315,320 350,400,500 630,700,800 |
AC800 AC1140 |
|||
Accessory selection rules | ||||||||||
YCM8 | MX | 1 | AC230V | |||||||
Model | Accessories | Adapter shell frame |
Accessory voltage |
|||||||
YCM8 | OF:Auxiliary contact MX:Shunt release SD:Alarm module Z:Manual operation mechanism P:Electric operating mechanism TS2:Terminal shield 2P TS3:Terminal shield 3P |
1:250/320 2:400/630/800 |
MX: AC110V AC230V AC400V DC24V |
P: AC400V AC230V DC220V |
Technical data
Model |
YCM8- 250HU |
YCM8- 320HU |
YCM8- 400HU |
|||||||||||||||||||||||
Appearance |
|
|
|
|||||||||||||||||||||||
Shell frame current Inm(A) |
250 |
320 |
400 |
|||||||||||||||||||||||
Number of poles of products |
|
|
3 |
|||||||||||||||||||||||
AC working voltage(V) |
415 |
690 |
800 |
1140 |
415 |
690 |
800 |
1140 |
415 |
690 |
800 |
1140 |
||||||||||||||
Rated insulation voltageUi(V) |
AC1150 |
AC1150 |
AC1150 |
|||||||||||||||||||||||
Rated impulse withstand voltage Uimp(KV) |
8 |
8 |
12 |
|||||||||||||||||||||||
Rated current In(A) |
63, 80, 100, 125, 140, 160, 180, 200, 225, 250 |
280, 315, 320 |
225, 250, 315, 350, 400 |
|||||||||||||||||||||||
Ultimate short-circuit breaking capacity Icu (kA) |
S |
85 |
50 |
36.5 |
10 |
85 |
50 |
36.5 |
10 |
85 |
50 |
36.5 |
10 |
|||||||||||||
N |
/ |
/ |
100 |
60 |
50 |
15 |
||||||||||||||||||||
Running short-circuit breaking capacity Ics(kA) |
Ics=100%Icu |
|||||||||||||||||||||||||
Wiring method |
Up in and down out, down in and up out, Down in and up out, up in and down out(3P) |
|||||||||||||||||||||||||
Isolation function |
Yes |
|||||||||||||||||||||||||
Tripping type |
Thermal-magnetic type |
|||||||||||||||||||||||||
Electrical life(time) |
3000 |
3000 |
2000 |
3000 |
3000 |
2000 |
1000 |
1000 |
700 |
|||||||||||||||||
Mechanical life(time) |
20000 |
20000 |
10000 |
|||||||||||||||||||||||
Standard |
IEC/EN60947-2 |
|||||||||||||||||||||||||
Attached accessories |
Shunt、Alarm、Auxiliary、Manual operation、Electric operation |
|||||||||||||||||||||||||
Certifications |
CE |
|||||||||||||||||||||||||
Overall dimension (mm) |
|
|
Width(W) |
107 |
107 |
182 |
||||||||||||||||||||
Height(H) |
180 |
180 |
250 |
|||||||||||||||||||||||
Depth(D) |
126 |
126 |
165 |
Note: ① 2P connection in series, ② 3P connection in series
Technical data
Model |
YCM8-630HU |
YCM8-800HU |
|||||||||||||||||
Appearance |
|
|
|||||||||||||||||
Shell frame current Inm(A) |
630 |
800 |
|||||||||||||||||
Number of poles of products |
3 |
3 |
|||||||||||||||||
AC working voltage(V) |
415 |
690 |
800 |
1140 |
415 |
690 |
800 |
1140 |
|||||||||||
Rated insulation voltageUi(V) |
AC1150 |
AC1150 |
|||||||||||||||||
Rated impulse withstand voltage Uimp(KV) |
12 |
12 |
|||||||||||||||||
Rated current In(A) |
500, 630 |
630,700, 800 |
|||||||||||||||||
Ultimate short-circuit breaking capacity Icu (kA) |
S |
85 |
50 |
36.5 |
10 |
85 |
50 |
36.5 |
10 |
||||||||||
N |
100 |
60 |
50 |
15 |
100 |
60 |
50 |
15 |
|||||||||||
Running short-circuit breaking capacity Ics(kA) |
Ics=100%Icu |
||||||||||||||||||
Wiring method |
Up in and down out, down in and up out, Down in and up out, up in and down out(3P) |
||||||||||||||||||
Isolation function |
Yes |
||||||||||||||||||
Tripping type |
Thermal-magnetic type |
||||||||||||||||||
Electrical life(time) |
1000 |
1000 |
1000 |
700 |
1000 |
1000 |
1000 |
700 |
|||||||||||
Mechanical life(time) |
5000 |
5000 |
|||||||||||||||||
Standard |
IEC/EN60947-2 |
||||||||||||||||||
Attached accessories |
Shunt、Alarm、Auxiliary、Manual operation、Electric operation |
||||||||||||||||||
Certifications |
CE |
||||||||||||||||||
Overall dimension (mm) |
|
|
Width(W) |
182 |
182 |
||||||||||||||
Height(H) |
250 |
250 |
|||||||||||||||||
Depth(D) |
165 |
165 |
Accessories
Accessory code |
Accessory name |
250/320HU |
400/630/800HU |
|
SD |
Alarm contact |
|
|
|
|
|
|
|
|
MX |
Shunt release |
|
|
|
|
|
|
|
|
OF |
Auxiliary contact(1NO1NC) |
|
|
|
OF+OF |
Auxiliary contact(2NO2NC) |
|
|
|
|
|
|
|
|
MX+OF |
Shunt release+ Auxiliary contact(1NO1NC) |
|
|
|
|
|
|
|
|
OF+OF |
2 sets of auxiliary contacts(2NO2NC) |
|
|
|
MX+SD |
Shunt release + Alarm contact |
|
|
|
|
|
|
|
|
OF+SD |
Auxiliary contact + Alarm contact |
|
|
|
|
|
|
|
|
MX+OF+SD |
Shunt release Auxiliary contact(1NO1NC)+ Alarm contact |
|
||
OF+OF+SD |
2 sets of auxiliary contacts(2NO2NC)+Alarm contact |
|
|
Auxiliary contact
Auxiliary contact current parameters
Rated current of shell frame grade |
Agreed heating current Ith |
The rated working current at AC 400V |
Inm<320 |
3A |
0.30A |
Inm>400 |
6A |
0.40A |
Auxiliary contact and its combination
When the circuit breaker is in the "off" position |
F12 F14 F22 F24 |
|
F11 F21 |
F12 F14 |
|
F11 |
|
When the circuit breaker is in the "on" position |
F12 F14 |
F11 |
|
F22 F24 |
F21 |
||
F12 F14 |
|
F11 |
Alarm contact
Alarm contact and its combination
Alarm contact Ue=220V, Ith=3A |
|
||
When the circuit breaker is in the "off"and "on"position |
B14 B14 |
|
B11 |
When the circuit breaker is in the "free trip" position |
B14 B12 |
|
B11 |
Shunt release
Generally installed in the Phase A of the circuit breaker, when the rated control power voltage is between 70% - 110%, the shunt releaseshall make the circuit breaker trip reliably under all operating conditions.
Control voltage: conventional: AC 50Hz, 110V, 230V, 400V, DC 24V.
Note: when the power supply of the control circuit is DC24V, the following figure is recommended for the design of the shunt control circuit.
KA: DC24V intermediate relay, contact current capacity is 1A
K: the microswitch in series with the coil inside the release aid is a normally closed contact. When the circuit breaker is disconnected, the contact will automatically disconnect and close when it is closed.
Wiring diagram
Installation method and overall dimension of external accessories
Model and specification of rotating operating handle mechanism
Model |
Installation dimension(mm) |
Central value of the operating handle relative to the circuit breaker(mm) |
|||
A |
B |
H |
D |
||
YCM8-250/320HU |
157 |
35 |
55 |
50-150 |
0 |
YCM8-400/630/800HU |
224 |
48 |
78 |
50-150 |
±5 |
Schematic diagram of hole opening of rotating operating handle
Overall and mounting dimension of external accessories
Model and specification of rotating operating handle mechanism
Model |
H |
B |
B1 |
A |
A1 |
D |
YCM8-250/320HU |
188.5 |
116 |
126 |
90 |
35 |
4.2 |
YCM8-400/630/800HU |
244 |
176 |
194 |
130 |
48 |
6.5 |
Model |
L |
A |
B |
C |
E |
||
Without zero arcing cover |
With zero arcing cover |
Without zero arcing cover |
With zero arcing cover |
||||
YCM8-250HU |
40 |
100 |
165 |
40 |
40 |
100 |
165 |
YCM8-320HU |
40 |
100 |
165 |
40 |
40 |
100 |
165 |
YCM8-400HU |
40 |
100 |
165 |
40 |
40 |
100 |
165 |
YCM8-630HU |
40 |
100 |
165 |
40 |
40 |
100 |
165 |
YCM8-800HU |
40 |
100 |
165 |
40 |
40 |
100 |
165 |