Product Overview
Product Details
Data Download
Related Products
Contact Us
Distribution Apparatus
YCM7T/A, RT Thermal Magnetic Adjustable MCCB
Selection Guide
Type |
The adjustable type |
Frame Inm |
Breaking capacity ICU/ICS(kA) |
Operation |
YCM7 RT 160 M Z |
||||
MCCB |
RT: Therm-mag T/A: Therm |
160, 250, 630, 800 Remark: 160 Frame upgrade from 125 250 Frame upgrade from 225 630 Frame upgrade from 400 |
M
50/35 50/35 50/35 |
P: Motor-driven |
Poles |
Tripping mode and inner accessory |
Rated current(A) Application |
|
3 300 160 2 |
|||
2: 2P 3: 3P 4: 4P |
First figure means tripping unit way 2: Only with magnetic release 3: Thermal release+,magnetic release body
Remark: The last two figures means accessory code (see accessories list) |
160 50-63, 63-80, 80-100, 100-125, 125-160 250 100-125, 125-160, 160-200, 200-250 400 200-250, 250-320, 320-400 630 400-500, 500-630 800 500-630, 630-800 |
1. Power distribution 2. Motor-protection |
Option for 4P MCCB |
Accessory voltage |
Motor-driven operation voltage |
Connection |
Connection plate |
||
A |
Q1 |
D |
Q |
2 |
||
A: N pole without |
UVT |
Shunt |
DC1 DC3 |
Q: Front |
1: W/O |
|
protection, N poleis always ON B: N pole without |
Q1: AC220V |
F1: AC220V |
D1: AC220V D5: AC220V |
H: Rear |
2: W |
|
Q2: AC240V |
F2: AC380V |
D2: AC230V D6: AC110V |
C: Plug-in |
|
||
Q3: AC380V |
F3: DC110V |
D3: AC380V D7: DC220V |
|
|
||
protection, |
Q4: AC415V |
F4: DC24V |
D4: AC400V D8: DC110V |
|
|
|
N pole makes with the |
|
J1: AC125V |
D9: AC110~240V |
|
|
|
other three poles |
|
J2: AC250V J3: DC125 J4: DC24V |
Remark: |
D10: DC100~220V |
|
|
DC1, DC3 motor-driven operation voltage see extenal accessories table. |
Inner Accessories
Model |
YCM7T/A-160 YCM7RT-160 |
YCM7T/A-250 YCM7RT-250 |
YCM7T/A-400/630 YCM7RT-400/630 |
YCM7T/A-800 YCM7RT-800 |
|||
Breaking capacity |
S |
S |
S,M |
M |
|||
No. of poles |
3 |
4 |
3 |
4 |
3,4 |
3,4 |
|
Code |
Accessory name |
|
|
|
|
||
208, 308 |
Alarm contact |
|
|
|
|
|
|
210, 310 |
Shunt release |
|
|
|
|
|
|
220, 320 |
Auxiliary contact |
|
|
|
|
|
|
230, 330 |
Under-voltage release |
|
|
|
|
|
|
240, 340 |
Shunt auxiliary contact |
|
|
|
|
|
|
260, 360 |
Two groups auxiliary contacts |
|
|
|
|
|
|
270, 370 |
Auxiliary contact UVT |
|
|
|
|
|
|
218, 318 |
Shunt alarm contact |
|
|
|
|
|
|
228, 328 |
Auxiliary alarm contact |
|
|
|
|
|
|
238, 338 |
UVT alarm contact |
|
|
|
|
|
|
248, 348 |
Shunt auxiliary alarm contact |
|
|
|
|
|
|
268, 368 |
Two groups aux alarm contact |
|
|
|
|
|
|
278, 378 |
Aux contact UVT alarm contact |
|
|
|
|
|
|
280, 380 |
Two groups aux contact and shunt |
|
|
|
|
|
Technical Data |
||||
Type Frame(A) Number of poles
Products
Rate current adjustable range(A) Rated voltage Ue(V) Rated insulation voltage Ui(V) |
YCM7T/A-160S YCM7RT-160S 160 3,4
50-63,63-80,80-100, 100-125,125-160 AC400V AC800V 25/18 3000 7000 ● ● Thermo-magnetic |
YCM7T/A-250S YCM7RT-250S 250 3,4
100-125,125-160, 160-200,200-250, AC400V AC800V 25/18 3000 7000 ● ● Thermo-magnetic |
YCM7T/A-400S YCM7RT-400S 400 3,4
200-250,250-320, 320-400 AC400V AC800V 35/25 2000 4000 ● ● Thermo-magnetic |
|
Short-circuit breaking capacity Icu/1cs(kA) Operation life (cycle) Motor-driven operation External rotary handle Automatic tripping device |
AC400V ON OFF |
Type | YCM7T/A-400M YCM7RT-400M |
YCM7T/A-630M YCM7RT-630M |
YCM7T/A-800M YCM7RT-800M |
|||
Frame(A) | 400 | 630 | 800 | |||
Number of poles | 34 | 34 | 34 | |||
Products | ||||||
Rate current adjustable range(A) | 200-250,250-320, 320-400 |
400-500,500-630 | 500-630,630-800 | |||
Rated voltage Ue(V) | AC400V | AC400V | AC400V | |||
Rated insulation voltage Ui(V) | AC800V | AC800V | AC800V | |||
Short-circuit breaking capacity Icu/1cs(kA) |
AC400V | 50/35 | 50/35 | 50/35 | ||
Operation life (cycle) | ON | 2000 | 2000 | 1500 | ||
OFF | 4000 | 4000 | 4000 | |||
Motor-driven operation | ● | 0 | ||||
External rotary handle | 0 | |||||
Automatic tripping device | Thermo-magnetic | Thermo-magnetic | Thermo-magnetic | |||
Means | accessory as option |
Front Connection & Overall
Thermal magnetic trip circuit breaker |
Thermal adjustable circuit breaker |
Overall dimensions |
Installing dimensions |
Bolt |
|||||||||||||||||||||
A |
A1 |
A2 |
A3 |
B |
B1 |
B2 |
B3 |
B5 |
B6 |
H |
H1 |
H2 |
H3 |
H4 |
H5 |
H6 |
A4 |
B4 |
|||||||
3P |
4P |
3P |
4P |
3P |
4P |
3P |
3P |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
YCM7RT-160S |
YCM7T/A-160S |
90 |
120 |
60 |
90 |
- |
- |
- |
- |
155 |
134 |
103 |
50 |
50 |
- |
94 |
72 |
4 |
68 |
61 |
41 |
24 |
30 |
132 |
M8 |
YCM7RT-250S |
YCM7T/A-250S |
105 |
140 |
70 |
105 |
- |
- |
- |
- |
165 |
144 |
103 |
50 |
100 |
- |
96 |
72 |
4 |
68 |
61 |
46 |
24 |
35 |
126 |
M8 |
YCM7RT-400S |
YCM7T/A-400S |
140 |
185 |
88 |
132 |
140 |
196 |
112 |
168 |
257 |
230 |
179 |
90 |
110 |
43 |
155 |
107 |
5 |
105 |
97 |
64 |
36 |
44 |
194 |
M10 |
YCM7RT-400M |
YCM7T/A-400M |
140 |
185 |
88 |
132 |
140 |
196 |
112 |
168 |
257 |
230 |
179 |
90 |
110 |
43 |
155 |
107 |
5 |
105 |
97 |
64 |
36 |
44 |
194 |
M10 |
YCM7RT-630M |
YCM7T/A-630M |
140 |
185 |
88 |
132 |
140 |
196 |
112 |
168 |
257 |
230 |
179 |
90 |
110 |
42 |
155 |
107 |
5 |
105 |
97 |
64 |
36 |
44 |
194 |
M10 |
YCM7RT-800M |
YCM7T/A-800M |
210 |
280 |
140 |
210 |
180 |
250 |
140 |
210 |
275 |
243 |
192 |
90 |
110 |
87 |
155 |
107 |
5 |
104 |
97 |
65 |
24 |
70 |
242.5 |
M12 |