General YCM7RE Series Electronic circuit breaker is suitable for ac 50 Hz, rated voltage 690V, the rated working current 800A low voltage power grid.

Contact Us

Product Details

Suitable Working Environment and Installation Condition

1. Altitude less than 2000m
2. Ambient medium temperature is from -5℃ to +40℃ (+45℃ for shipping product)
3. Humidity resistance
4. Bacteria resistance
5. Nuelear radiation resistance
6. Max lean degree is 22.5 degree.
7. Can operate normally when it comes to vibrataion of ship.
8. Can operate normally when it comes to earthquake(4g).
9. The medium should be no risk of blasting and can't erode the metal and damage insulating gas as well as conductive dust.
10. Work in the places where is no rain and snow.

Features

1. Above MCCB can put accessories such as, UVT, Shunt, Aux, Alarm contact, Motor driven operation, Mechanism, Rotary handle.
2. Function available as over-load long-time delay, short-circuit time-delay,instant protection.
3. Earth-fault protection, Thermal analog Pre-alarm, indication, Over-current, indication operational current.

product-description1

Notice

1. Ir: Adjustable setting value of over-load protection, it could be adjusted as per customer's requirements;
2. Tr: Adjustable setting value of long time-delay operated time Tr±20%, tripping time at the status of 6Ir can be set as per customer's requirements;
3. Is: Adjustable setting value of short time-delay current;
4. Ts: Adjustable setting value of short time-delay operated time, it is divided into two types: fixed time limit Ts (0.05s, 0.1s, 0.15s, 0.2s, 0.3s) and reverse time limit Ts (0.05s, 0.1s, 0.15s, 0.2s, 0.3s).
5. Ii: Adjustable setting value of instant current;
6. Ip: Adjustable setting value of over-load alarm current.

product-description2

product-description3 product-description4

product-description5

B-配电系列.cdr
B-配电系列.cdr
Thermal magnetic trip  circuit breaker Overall dimensions Installing   dimensions Bolt
A A1 A2 A3 B B1 B2 B3 B5 B6 H H1 H2 H3 H4 H5 H6 A4 B4
3P 4P 3P 4P 3P 4P 3P 3P
YCM7RE-160M 90 120 60 90 - - - - 155 134 102 50 50 - 109 83 4 68 61 20.7 24 30 132 M8
YCM7RE-250M 105 140 70 105 - - - - 165 144 102 50 100 - 120 91 4 68 61 45 24 35 126 M8
YCM7RE-400M 140 185 88 132 140 196 112 168 257 230 179 90 110 42 155 107 5 105 97 45 36 44 194 M10
YCM7RE-630M 140 185 88 132 140 196 112 168 257 230 179 90 110 42 155 107 5 105 97 45 36 44 194 M10
YCM7RE-800M 210 280 140 210 180 250 140 210 275 243 192 90 110 87 155 107 5 104 97 15 24 70 243 2xM8