YCM3T/A Molded Case Circuit Breaker
YCM3T/A Molded Case Circuit Breaker
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCM3T/A Molded Case Circuit Breaker
Picture
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker
  • YCM3T/A Molded Case Circuit Breaker

YCM3T/A Molded Case Circuit Breaker

General
Operating conditions
YCM3 Series moulded case circuit breaker, is new products, with small compact, modular, high break, double breakpoints, zero arcing, green environmental protection. Suitable for AC 50Hz, 60Hz, rated operating voltage 690V and below, rated current 12.5A to 1600A distribution network, used to distribute electrical energy and protection lines and power supply equipment from overload, short circuit and undervoltage failure hazards. It can also be used as a non-frequent conversion of the line under normal conditions and in the infrequent start of the motor.

Contact Us

Product Details

YCM3T/A

 

 

 

 

 

YCM3RT

 

 

 

 

 

 

 

YCM3E

 

 

 

 

 

 

YCM3Y

 

 

 

 

 

YCM3Y With communication

 

 

 

 

 

YCM3LE With residual current module

General

YCM3 Series moulded case circuit breaker, is new products, with small compact,modular, high break, double breakpoints, zero arcing, green environmental protection. Suitable for AC 50Hz, 60Hz, rated operating voltage 690V and below,rated current 12.5A to 1600A distribution network, used to distribute electrical energy and protection lines and power supply equipment from overload, short circuit and undervoltage failure hazards. It can also be used as a non-frequent conversion of the line under normal conditions and in the infrequent start of the motor.
YCM3 circuit breaker equips with intelligent controller as well, which not only makes its current adjustable but also grants protection against overload(long delay), short
circuit(short delay), short-circuit(instantaneous) & undervoltage. It'll certainly improve the entire power system's reliability, continuity & security. RS485 interface,MODBUS-RTU protocol.With MODBUS modul equipped,customers can choose options as below. Remote signal: Switching ON/OFF, tripping, alarm & malfunctional singal indication.
Remote control: Switching ON/OFF,reset.Remote test: 3-phase cuttent & N-pole current, grounding current. Remote adjustment: accept and execute remote command to debug remote control .Tripping unit memory recording function, last three time' tripping records can be well traced. YCM3 circuit breaker also obtains isolation function(Can be used as an alternative load switch).
Standard: IEC 60947-2.

Operating conditions
1.The altitude of the installation site does not exceed 2000m;
2.The YCM3 thermomagmetic type with temperatureof the surrounding medium is-5℃~+40℃,and the average temperature of 24 h is not more than +35℃.Threlative humidity of the air at the installation site does not exceed 50%atmaximum temperature of +40℃;at lower temperatures,there may be a higherelative humidity;the average minimum temperatureof the wettest month does ncexceed +25℃ for the average of the month The maximum relative humidity is ncmore than 90%,and the condensation on the surface of the product due ttemperature changes is considered.
3.YCM3 intellgent type with temperature of the surrounding medium is40℃~+80℃.
4.The product is used in non-explosive hazardous media,and the media does nothave enough to corrde metals and destroyinsulating gases and conductve dust.
5.In places where there is rain protection and no water vapor.
6.The installation category is Class Ⅲ.
7.The pollution level is level 3.
8.The basic installation of the circuit breaker isvertical (ie vertical)or horizontal
(iehorizontal).
9.The incoming line is either the up line orthe down line.
10.Circuit breakers can be divided into fixed and plug-in types.

 

Note:

Other requirements at the time of ordering are subject to textual instructions.

 

Release:

The type of stripper is divided into: thermal magnetic stripper and lntelligent stripper 1.  Thermal  magnetic  stripper  is  divided  into  types  according  to  protection  type

Distribution Protection Code: TM; Motor (single-magnetic) protection Code: MA. 2. Intelligent stripper According to the function is divided into three kinds:

ordinary type, liquid crystal type and with voltage detection type.

 

 

 

 

 

Circuit breaker protection settings are shown in table 1
Type of Stripper Type Overload longdelay settingcurrent(IR) Overload longdelay (6·IN)Fix buckletime Short-circuitshorter delaytuning current(ISD) Short-circuitshorter delaysetting time(TSD) Short-circuittransienttuning current(Ii) GroundingProtectionsetting current(IG) GroundingProtectionsetting time(TG)
MA:Single magnetic

YCM3MA100

YCM3MA160

YCM3MA250

YCM3MA-400

YCM3MA-630

/ / / / 12In / /
T/A:Overload adjustable

YCM3T/A-100

YCM3T/A-160

YCM3T/A-250

(0.8~1)In / / / 10In / /
RT:Overload+short circuit adjustable YCM3RT-250 (200~250A) (0.8~1)In / / / (5~10)In / /
YCM3RT-400 YCM3RT-630 (0.7~1)In
  E(2.0E):Electronic 2.0E

YCM3E-100  2.0E

YCM3E-160 2.0E

YCM3E-250 2.0E

YCM3E-400 2.0E

YCM3E-630 2.0E

(0.4~1)In / (1.5~10)Ir  / 12In  /  /
YCM3E-1250 2.0EYCM3E-1600 2.0E (0.4~1)In 0.5~24s (1.5~10)Ir 12In
  E(3.0E):Electronic 3.0E

YCM3E-100 3.0E

YCM3E-160 3.0E

YCM3E-250 3.0E

YCM3E-400 3.0E

YCM3E-630 3.0E

(0.4~1)In 0.5~12s (1.5~12)Ir 0.1s~0.4s (2~15)In

(20%~100%)In

/
YCM3E-1250 3.0EYCM3E-1600 3.0E (0.4~1)In 0.5~24s (1.5~10)Ir 0.1s~0.4s (2~15)In Optional /
Y:LCD display, Current typeYV:LCD display, Voltage typeYP:LCD display, Power type YCM3Y(YV、YP)-100

YCM3Y(YV、YP)-160

YCM3Y(YV、YP)-250

YCM3Y(YV、YP)-400

YCM3Y(YV、YP)-630

(0.4~1)In 0.5~12s (1.5~12)Ir 0s~0.4s (2~15)In (20%~100%)In 0s~0.4s
YCM3Y(YV、YP)-1250YCM3Y(YV、YP)-1600 (0.4~1)In 0.5~24s (1.5~12)Ir 0s~0.4s (2~15)In (20%~100%)In 0s~0.4s

YCM3 parameter measurement function is shown in table 2

 

function type functional category Specific functions Monomagnetic Thermomagnetic Electronic
MA T/A RT 2.0E 3.0E Y YV YP
 

 

 

Protection function

 

Current (A)

overload protection /
Short circuit short time delay protection / / /
Instantaneous protection
Overload warning / / /
Neutral line protection
Grounding protection / / / / /
Current imbalance protection / / / / / /
Voltage(v) Zero break protection / / / / / /
Voltage imbalance protection / / / / / /
Overfrequency and underfrequency protection / / / / / /
Phase sequence protection / / / / / /
 

 

 

 

Measurement function

Current (A) Phase current / / / / /
Neutral current / / / / /
Percentage of ground faults / / / / / /
Current imbalance rate of each phase / / / / / /
 

 

 

Voltage(V)

Line voltage / / / / / /
Phase voltage / / / / / /
Average line voltage / / / / / /
Average phase voltage / / / / / /
Voltage imbalance rate / / / / / /
phase sequence / / / / / /
frequency / / / / / /
Power Meritorious / / / / / / /
Reactive power / / / / / / /
Apparent / / / / / / /
Power factor and / / / / / / /
Quantity of electricity Active, reactive, apparent / / / / / / /
 

 

 

 

Maintenance function

Accumulated function Various types of protection tripping times, displacement times, etc / / / / / /
Event recording Trip records, alarm records, displacement records, etc / / / / / /
Contact wear Contact wear record / / / / / /
Number of operations Record of operation times / / / / / /
RTC function Realtime clock / / / / / /

Auxiliary/alarm detection function

Auxiliary, alarm detection, and display of circuit breaker status / / / / / /

Electric operation control function

Remote electric operation control function / / / / / /
human-computer interaction LED indication / / / / /
LCD display / / / / /
Key settings / / / / /
communication function Moedbus RTU DL/T645 / / / / /
Type YCM3-100 YCM3-160 YCM3-250
Number of poles 3P, 4P 3P, 4P 3P, 4P
Shell frame maximum rated current Inm(A) 100 160 250
Rated current In(A) 12.5/16/2025/32/40

50/63/80/100

100

16/20/25/32 40/50/63/80 100/125/160

160 100/160/180 200/225/250 250
Type of Stripper Thermal or     single-magnetic Intelligent type Thermal or     single-magnetic Intelligent type Thermal or     single-magnetic

Intelligent type

Rated insulation voltage Ui(V) 800 800 800
Rated impulse withstand voltage Uimp(kV) 8 8 8
Rated voltage Ue(V)50-60Hz AC415/500/690 AC415/500/690 AC415/500/690
Flying arc Distance(mm) 0 0 0
Short circuit breaking capability level N H N H N H
Rated limit Short AC415V 50 85 50 85 50 85
circuit Breaking  capacity Icu(kA) AC500V 35 50 50 60 50 60
AC690V 6 6 6 6 6 6
Rated running short circuit Breakingcapacity Ics(kA) AC415V 75% Icu
AC500V
AC690V
Rated short time resistant current Icw(kA) (1s) / 3                       / 3                       / 3
Working with categories A A A
Remaining Current protection Additional Residual current protection module(See P78-79 LE remaining current module for specific parameters)
Electrical Life Test AC415V 10000 10000 8000 8000 8000 8000
AC690V 1500 1500 1500 1500 1500 1500
Number of mechanical life 20000 20000 20000 20000 20000 20000
 

Dimensions

Wide(3P/4P) 105/140 105/140 105/140
Long 161 161 161
High 86 86 86
Mode of operation Manual Direct operation、 Rotate handle operation、 Electric operating mechanism
Mounting method Fixed type(front of plate)、 Fixed type(rear of plate)、 Plug-in(front of plate)、 Plug-in(rear of plate)
Type YCM3-400 YCM3-630 YCM3-1600
Number of poles 3P, 4P 3P, 4P 3P, 4P
Shell frame maximum rated current Inm(A) 400 630 1600
Rated current In(A) 250/315/ 350/400 400 400/500/ 600/630 630 800/1000/1250/1600
Type of Stripper Thermal or     single-magnetic Intelligent type Thermal or     single-magnetic Intelligent type Intelligent type
Rated insulation voltage Ui(V) 1000 1000 1000
Rated impulse withstand voltage Uimp(kV) 8 8 8
Rated voltage Ue(V)50-60Hz AC415/500/690 AC415/500/690 AC415/500/690
Flying arc Distance(mm) 0 0 0
Short circuit breaking capability level N H N H N
Rated limit Short circuitBreaking    capacity Icu(kA) AC415V 50 85 50 85 50
AC500V 30 50 35 50 35
AC690V 10 15 10 100 20
Rated running short circuit Breakingcapacity Ics(kA) AC415V 75% Icu
AC500V
AC690V

Rated short time resistant current ICW (kA) (1s)

/ 5 / 8 8
Working with categories A B A B B
Remaining Current protection Additional Residual current protection module(See P78-79 LE remaining current module for specific parameters)
Electrical Life Test AC415V 6000 6000 5000 5000 1500
AC690V 1000 1000 1000 1000 1000 1000
Number of mechanical life 10000 10000 10000 10000 10000 10000
Dimensions Wide(3P/4P) 140/185 140/185 210/280
Long 255 255 327
High 110 110 147
Mode of operation Manual Direct operation、Rotate handle operation、Electric operating mechanism
Mounting method Fixed type(front of plate)、Fixed type(rear of plate)、Plug-in(front of plate)、Plug-in(rear of plate)
Write your message here and send it to us