Product Overview
Product Details
Data Download
Related Products
Contact Us
YCM3T/A
YCM3RT
YCM3E
YCM3Y
YCM3Y With communication
YCM3LE With residual current module
General
Operating conditions
1.The altitude of the installation site does not exceed 2000m;
2.The YCM3 thermomagmetic type with temperatureof the surrounding medium is-5℃~+40℃,and the average temperature of 24 h is not more than +35℃.Threlative humidity of the air at the installation site does not exceed 50%atmaximum temperature of +40℃;at lower temperatures,there may be a higherelative humidity;the average minimum temperatureof the wettest month does ncexceed +25℃ for the average of the month The maximum relative humidity is ncmore than 90%,and the condensation on the surface of the product due ttemperature changes is considered.
3.YCM3 intellgent type with temperature of the surrounding medium is40℃~+80℃.
4.The product is used in non-explosive hazardous media,and the media does nothave enough to corrde metals and destroyinsulating gases and conductve dust.
5.In places where there is rain protection and no water vapor.
6.The installation category is Class Ⅲ.
7.The pollution level is level 3.
8.The basic installation of the circuit breaker isvertical (ie vertical)or horizontal
(iehorizontal).
9.The incoming line is either the up line orthe down line.
10.Circuit breakers can be divided into fixed and plug-in types.
Note:
Other requirements at the time of ordering are subject to textual instructions.
Release:
The type of stripper is divided into: thermal magnetic stripper and lntelligent stripper 1. Thermal magnetic stripper is divided into types according to protection type
Distribution Protection Code: TM; Motor (single-magnetic) protection Code: MA. 2. Intelligent stripper According to the function is divided into three kinds:
ordinary type, liquid crystal type and with voltage detection type.
Type of Stripper | Type | Overload longdelay settingcurrent(IR) | Overload longdelay (6·IN)Fix buckletime | Short-circuitshorter delaytuning current(ISD) | Short-circuitshorter delaysetting time(TSD) | Short-circuittransienttuning current(Ii) | GroundingProtectionsetting current(IG) | GroundingProtectionsetting time(TG) |
MA:Single magnetic |
YCM3MA100 YCM3MA160 YCM3MA250 YCM3MA-400 YCM3MA-630 |
/ | / | / | / | 12In | / | / |
T/A:Overload adjustable |
YCM3T/A-100 YCM3T/A-160 YCM3T/A-250 |
(0.8~1)In | / | / | / | 10In | / | / |
RT:Overload+short circuit adjustable | YCM3RT-250 (200~250A) | (0.8~1)In | / | / | / | (5~10)In | / | / |
YCM3RT-400 YCM3RT-630 | (0.7~1)In | |||||||
E(2.0E):Electronic 2.0E |
YCM3E-100 2.0E YCM3E-160 2.0E YCM3E-250 2.0E YCM3E-400 2.0E YCM3E-630 2.0E |
(0.4~1)In | / | (1.5~10)Ir | / | 12In | / | / |
YCM3E-1250 2.0EYCM3E-1600 2.0E | (0.4~1)In | 0.5~24s | (1.5~10)Ir | 12In | ||||
E(3.0E):Electronic 3.0E |
YCM3E-100 3.0E YCM3E-160 3.0E YCM3E-250 3.0E YCM3E-400 3.0E YCM3E-630 3.0E |
(0.4~1)In | 0.5~12s | (1.5~12)Ir | 0.1s~0.4s | (2~15)In |
(20%~100%)In |
/ |
YCM3E-1250 3.0EYCM3E-1600 3.0E | (0.4~1)In | 0.5~24s | (1.5~10)Ir | 0.1s~0.4s | (2~15)In | Optional | / | |
Y:LCD display, Current typeYV:LCD display, Voltage typeYP:LCD display, Power type | YCM3Y(YV、YP)-100
YCM3Y(YV、YP)-160 YCM3Y(YV、YP)-250 YCM3Y(YV、YP)-400 YCM3Y(YV、YP)-630 |
(0.4~1)In | 0.5~12s | (1.5~12)Ir | 0s~0.4s | (2~15)In | (20%~100%)In | 0s~0.4s |
YCM3Y(YV、YP)-1250YCM3Y(YV、YP)-1600 | (0.4~1)In | 0.5~24s | (1.5~12)Ir | 0s~0.4s | (2~15)In | (20%~100%)In | 0s~0.4s |
YCM3 parameter measurement function is shown in table 2
function type | functional category | Specific functions | Monomagnetic | Thermomagnetic | Electronic | |||||
MA | T/A | RT | 2.0E | 3.0E | Y | YV | YP | |||
Protection function |
Current (A) |
overload protection | / | ■ | ■ | ■ | ■ | ■ | ■ | ■ |
Short circuit short time delay protection | / | / | / | ■ | ■ | ■ | ■ | ■ | ||
Instantaneous protection | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ||
Overload warning | / | / | / | ■ | ■ | ■ | ■ | ■ | ||
Neutral line protection | ||||||||||
Grounding protection | / | / | / | / | / | ■ | ■ | ■ | ||
Current imbalance protection | / | / | / | / | / | / | ■ | ■ | ||
Voltage(v) | Zero break protection | / | / | / | / | / | / | ■ | ■ | |
Voltage imbalance protection | / | / | / | / | / | / | ■ | ■ | ||
Overfrequency and underfrequency protection | / | / | / | / | / | / | ■ | ■ | ||
Phase sequence protection | / | / | / | / | / | / | ■ | ■ | ||
Measurement function |
Current (A) | Phase current | / | / | / | / | / | ■ | ■ | ■ |
Neutral current | / | / | / | / | / | |||||
Percentage of ground faults | / | / | / | / | / | / | ■ | ■ | ||
Current imbalance rate of each phase | / | / | / | / | / | / | ■ | ■ | ||
Voltage(V) |
Line voltage | / | / | / | / | / | / | ■ | ■ | |
Phase voltage | / | / | / | / | / | / | ■ | ■ | ||
Average line voltage | / | / | / | / | / | / | ■ | ■ | ||
Average phase voltage | / | / | / | / | / | / | ■ | ■ | ||
Voltage imbalance rate | / | / | / | / | / | / | ■ | ■ | ||
phase sequence | / | / | / | / | / | / | ■ | ■ | ||
frequency | / | / | / | / | / | / | ■ | ■ | ||
Power | Meritorious | / | / | / | / | / | / | / | ■ | |
Reactive power | / | / | / | / | / | / | / | ■ | ||
Apparent | / | / | / | / | / | / | / | ■ | ||
Power factor and | / | / | / | / | / | / | / | ■ | ||
Quantity of electricity | Active, reactive, apparent | / | / | / | / | / | / | / | ■ | |
Maintenance function |
Accumulated function | Various types of protection tripping times, displacement times, etc | / | / | / | / | / | / | ■ | ■ |
Event recording | Trip records, alarm records, displacement records, etc | / | / | / | / | / | / | ■ | ■ | |
Contact wear | Contact wear record | / | / | / | / | / | / | ■ | ■ | |
Number of operations | Record of operation times | / | / | / | / | / | / | ■ | ■ | |
RTC function | Realtime clock | / | / | / | / | / | / | ■ | ■ | |
Auxiliary/alarm detection function |
Auxiliary, alarm detection, and display of circuit breaker status | / | / | / | / | / | / | |||
Electric operation control function |
Remote electric operation control function | / | / | / | / | / | / | ■ | ■ | |
human-computer interaction | LED indication | / | / | / | / | / | ■ | ■ | ■ | |
LCD display | / | / | / | / | / | ■ | ■ | ■ | ||
Key settings | / | / | / | / | / | ■ | ■ | ■ | ||
communication function | Moedbus RTU DL/T645 | / | / | / | / | / | ■ | ■ |
Type | YCM3-100 | YCM3-160 | YCM3-250 | |||||||
Number of poles | 3P, 4P | 3P, 4P | 3P, 4P | |||||||
Shell frame maximum rated current Inm(A) | 100 | 160 | 250 | |||||||
Rated current In(A) | 12.5/16/2025/32/40
50/63/80/100 |
100 |
16/20/25/32 40/50/63/80 100/125/160 |
160 | 100/160/180 200/225/250 | 250 | ||||
Type of Stripper | Thermal or single-magnetic | Intelligent type | Thermal or single-magnetic | Intelligent type | Thermal or single-magnetic |
Intelligent type |
||||
Rated insulation voltage Ui(V) | 800 | 800 | 800 | |||||||
Rated impulse withstand voltage Uimp(kV) | 8 | 8 | 8 | |||||||
Rated voltage Ue(V)50-60Hz | AC415/500/690 | AC415/500/690 | AC415/500/690 | |||||||
Flying arc Distance(mm) | 0 | 0 | 0 | |||||||
Short circuit breaking capability level | N | H | N | H | N | H | ||||
Rated limit Short | AC415V | 50 | 85 | 50 | 85 | 50 | 85 | |||
circuit Breaking capacity Icu(kA) | AC500V | 35 | 50 | 50 | 60 | 50 | 60 | |||
AC690V | 6 | 6 | 6 | 6 | 6 | 6 | ||||
Rated running short circuit Breakingcapacity Ics(kA) | AC415V | 75% Icu | ||||||||
AC500V | ||||||||||
AC690V | ||||||||||
Rated short time resistant current Icw(kA) (1s) | / | 3 / | 3 / | 3 | ||||||
Working with categories | A | A | A | |||||||
Remaining Current protection | Additional Residual current protection module(See P78-79 LE remaining current module for specific parameters) | |||||||||
Electrical Life Test | AC415V | 10000 | 10000 | 8000 | 8000 | 8000 | 8000 | |||
AC690V | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | ||||
Number of mechanical life | 20000 | 20000 | 20000 | 20000 | 20000 | 20000 | ||||
Dimensions |
Wide(3P/4P) | 105/140 | 105/140 | 105/140 | ||||||
Long | 161 | 161 | 161 | |||||||
High | 86 | 86 | 86 | |||||||
Mode of operation | Manual Direct operation、 Rotate handle operation、 Electric operating mechanism | |||||||||
Mounting method | Fixed type(front of plate)、 Fixed type(rear of plate)、 Plug-in(front of plate)、 Plug-in(rear of plate) |
Type | YCM3-400 | YCM3-630 | YCM3-1600 | |||||
Number of poles | 3P, 4P | 3P, 4P | 3P, 4P | |||||
Shell frame maximum rated current Inm(A) | 400 | 630 | 1600 | |||||
Rated current In(A) | 250/315/ 350/400 | 400 | 400/500/ 600/630 | 630 | 800/1000/1250/1600 | |||
Type of Stripper | Thermal or single-magnetic | Intelligent type | Thermal or single-magnetic | Intelligent type | Intelligent type | |||
Rated insulation voltage Ui(V) | 1000 | 1000 | 1000 | |||||
Rated impulse withstand voltage Uimp(kV) | 8 | 8 | 8 | |||||
Rated voltage Ue(V)50-60Hz | AC415/500/690 | AC415/500/690 | AC415/500/690 | |||||
Flying arc Distance(mm) | 0 | 0 | 0 | |||||
Short circuit breaking capability level | N | H | N | H | N | |||
Rated limit Short circuitBreaking capacity Icu(kA) | AC415V | 50 | 85 | 50 | 85 | 50 | ||
AC500V | 30 | 50 | 35 | 50 | 35 | |||
AC690V | 10 | 15 | 10 | 100 | 20 | |||
Rated running short circuit Breakingcapacity Ics(kA) | AC415V | 75% Icu | ||||||
AC500V | ||||||||
AC690V | ||||||||
Rated short time resistant current ICW (kA) (1s) |
/ | 5 | / | 8 | 8 | |||
Working with categories | A | B | A | B | B | |||
Remaining Current protection | Additional Residual current protection module(See P78-79 LE remaining current module for specific parameters) | |||||||
Electrical Life Test | AC415V | 6000 | 6000 | 5000 | 5000 | 1500 | ||
AC690V | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
Number of mechanical life | 10000 | 10000 | 10000 | 10000 | 10000 | 10000 | ||
Dimensions | Wide(3P/4P) | 140/185 | 140/185 | 210/280 | ||||
Long | 255 | 255 | 327 | |||||
High | 110 | 110 | 147 | |||||
Mode of operation | Manual Direct operation、Rotate handle operation、Electric operating mechanism | |||||||
Mounting method | Fixed type(front of plate)、Fixed type(rear of plate)、Plug-in(front of plate)、Plug-in(rear of plate) |