YCM1 Molded Case Circuit Breaker
YCM1 Molded Case Circuit Breaker
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCM1 Molded Case Circuit Breaker
Picture
Video
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
  • YCM1 Molded Case Circuit Breaker
YCM1 Molded Case Circuit Breaker Featured Image

YCM1 Molded Case Circuit Breaker

General

YCM1 series moulded case circuit breaker(herein after called circuit breaker) adopts international advanced design and manufactural technology, it can be divided into L-type (standard type), M-type (higher type)according to the rated ultimate short circuit breaking capacity (Icu). With the features of small and compact, high breaking capacity, short arcing-over distance, anti-vibration, the circuit breaker is used popularly on land and marine products, which are applied for the power distribution network of AC 50Hz,rated insulation voltage 800V (YCM1-63 to 500V), rated working voltage 690V(YCM1-63 to 400V) and below, rated current up to 1600A. It can be used to distribute electric power and protect power equipment against overload, short circuit, undervoltage etc, It also takes protective effect when motors infrequently start and protects against overload, short circuit and lacking voltage. In the series, frame ranging from 63-630A three-pole product also comes with a transparent cover, it is convenient for customers to observe the product operation.
The circuit breaker can be installed vertically, or horizontally.
Standard : IEC60947-2.

Contact Us

Product Details

General

YCM1 series moulded case circuit breaker(herein after called circuit breaker) adopts
international advanced design and manufactural technology, it can be divided
into L-type (standard type), M-type (higher type)according to the rated ultimate
short circuit breaking capacity (Icu). With the features of small and compact, high
breaking capacity, short arcing-over distance, anti-vibration, the circuit breaker is
used popularly on land and marine products, which are applied for the power
distribution network of AC 50Hz,rated insulation voltage 800V (YCM1-63 to 500V),
rated working voltage 690V(YCM1-63 to 400V) and below, rated current up to
1600A. It can be used to distribute electric power and protect power equipment
against overload, short circuit, undervoltage etc, It also takes protective effect when
motors infrequently start and protects against overload, short circuit and lacking
voltage. In the series, frame ranging from 63-630A three-pole product also comes
with a transparent cover, it is convenient for customers to observe the product
operation.
The circuit breaker can be installed vertically, or horizontally.
Standard : IEC60947-2.
1.Blank for power distribution,2 for motor protection
2.Blank for direct operation with handle, Z for operation with rotary handle, P for
motor-driven operation.
3.There are 2 types of N-pole for 4P breaker:
A:Without current release components, N-Pole is always at making status(not
breakers);
B:Without current release components, N-Pole is made with the other three poles.

Curve

Operating conditions

1.Temperature: -5℃~+40℃; the average value within 24h shall not exceed +35℃. For the circuit breaker with thermo-magnetic
release, +40℃ is set to be the standard temperature for ratings. For temperature not between -5℃~+40℃, please contact us for
temperature compensation correction;
2.Altitude: not exceed 2000m (Please contact with us for reduction coefficient if altitude at the mounted site exceed 2000m)
3.Pollution grade: Grade 3;
4.Air conditions:
At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher relative humidity is allowable under
lower temperature. For example, RH could be 90% at +20℃. Special measures should be taken when dew occurs.

Technical data

Type YCM1-63 YCM1-125 YCM1-160 YCM1-250 YCM1-400 YCM1-630 YCM1-800 YCM1-1250 YCM1-1600
Poles P   3 3,4 2,3 3,4 3 2,3,4 34, 34, 3, 4 3 3
Rated current In A   10, 16,20, 25,32, 40,50, 63 10, 16,20, 25,32, 40,50, 63,80, 100,

125

100,125,140,160 100, 125,140 160,180, 200225, 250 225,250,315,350,400 400,500,630 630,700,800 800,1000,1250 1600
Rated insulation voltage Ui V   500 800
Rated impulsewithstand voltage Uimp V   6000 8000
Rated operation voltage Ue V   AC400 AC400/690
Breaking capacity class     L M L M L L M L M L M L M L M L M
Limit short-circuitbreaking capacity Icu kA 230V 35 50 35 50 35 35 50 50 75 50 75 - - - - - 85
400V 25 35 25 50 35 35 50 50 65 50 65 75 75 85 85 75 85
690V - - 8 10 8 8 10 10 20 10 20 - 30 - 30 - 30
Working short-circuit breaking capacity Ics kA 230V 18 50 18 50 22 22 50 50 50 50 50 - - - - - 50
400V 18 22 18 25 18 18 25 35 32.5 35 42.5 50 50 50 50 36 50
690V - - 4 5 4 4 5 5 10 5 10 - 15 - 15 - 15
Arcing distance mm 50 100
Operating frequency Electrical life 3000 3000 3000 3000 2000 2000 2000 800 500
mechanical life 20000 20000 20000 20000 10000 10000 10000 5000 2500

Inner accessories

  Release method and accessories code Accessories installation and down-leads
Accessories name Electromagnetic release Complex release YCM1-63  YCM1-125 YCM1-160 YCM1-250 YCM1-400 YCM1-630 YCM1-800  YCM1-1250
Without parts 200 300        
Alarm contact 208 308        
Shunt release 210 310        
Auxiliary contact 220 320        
Undervoltage release 230 330        
Shunt release,Auxiliary contact 240 340        
Shunt release,under-voltage release 250 350        
Secondary auxiliary contact 260 360        
Auxiliary contact,Undervoltage release 270 370        
Shunt release, Alarm contact 218 318        
Auxiliary contact, Alarm contact 228 328        
Undervoltage release, Alarm contact 238 338        
Shunt release,Auxiliary contact, Alarm contact 248 348        
Secondary auxiliary contact,Alarm contact 268 368        
Auxiliary contact,Alarm contact 278 378        

Overview

Overall and mounting dimensions(mm)

Type Overall size (mm) Installation size (mm)
W L H W1 W2 L1 H1 H2 A B Φd
YCM1-63L 78 135 74 50 - 156 92 28 25 117 3.5
YCM1-63M 78 135 82 50 103 156 100 28 25 117 3.5
YCM1-125L 92 150 68 60 - 200 88 24 30 129 4.5
YCM1-125M 92 150 86 60 122 200 105 24 30 129 4.5
YCM1-160L 93 151 76 60 - 200 96 24 30 129 4.5
YCM1-250L 107 165 86 70 - 215 110 24 35 126 5
YCM1-250M 107 165 103 70 142 215 127 24 35 126 5
YCM1-400L 150 257 107 96 198 357 162 38 44 194 7
YCM1-400M 150 257 107 96 198 357 162 38 44 194 7
YCM1-630L 182 271 112 116 240 370 165 42 58 200 7
YCM1-630M 182 271 112 116 240 370 165 42 58 200 7
YCM1-800M 210 280 116 140 280 385 168 42 70 243 7
YCM1-1250M YCM1-1600M 210 406 158 140 - 610 193 60 70 375 11

Overall and mounting dimensions(mm)

Model Dimensions Ue(V) Ie(A) Mechanical life(times) Motor power(W)
A B C D E
YCM1-63 25 117 74 102 79 K1 ≤0.5 14000 14
YCM1-100 30 129 90 116 77 K1 ≤0.5 14000 14
YCM1-250 35 126 90 116 77 K1 ≤0.5 14000 14
YCM1-400 44 194 130 176 115 K2 ≤2 5000 35
YCM1-630 58 200 130 176 115 K2 ≤2 5000 35
YCM1-800 70 243 130 176 115 K2 ≤2 5000 35
YCM1-1250 70 300 130 176 115 K2 ≤2 5000 35
YCM1-1600 70 300 130 176 115 K2 ≤2 2500 35