Product Overview
Product Details
Data Download
Related Products
General
The YCKG7 series time control switch is suitable for AC 50Hz,rated control powersupply voltage to AC380V control circuit,as a delay timing component.It canconnect or disconnect the power supply ofvarious control circuits according to thepredetermined time,suitable for street lights,neon lights,advertising signs,radioand television equipment,and various household appliancesStandard:IEC 60947-4-1
Contact Us
They ckG7 series time control switch is suitable for AC 50HZ, rated control power supply voltage to AC380v control circuit, as a delay timing component. It can connect or disconnect the power supply of various control circuits according to the predetermined time, suitable for street lights, neon lights, advertising signs, radio and television equipment, and various household appliances. standard: IEC 60947-4-1
1. Easy to setup and use
2. Anti-mis-touch function to prevent mis-touch operation
3. 16groups of switches can be set, with manual/automatic on or off 4. Rubber buttons to enhance user experience
5. smaller appearance and volume compared to conventional time control switches
6. Equipped with a detachable battery, the program is automatically saved after setting, and there is no need to set it again after a power outage
Rated insulation voltage ui | AC380 |
Rated impulse withstand voltage uimp | 2.5kv |
Rated control power supply voltage us | AC50/60HZ 220V 380V |
power consumption | 5W |
pollution level | 3 |
protection degrees of the frame | protection degrees of the frame |
Load power | under AC-12 use category, 20AAC250v (resistive) |
Timing times | 16 groups, both automatic and manual |
switching time | Day cycle or weekly cycle |
Time control range | 1min~168hour |
Mechanical life | 1 million times |
Electrical life | 100,000 times |
Altitude | 2000m |
Temperature | Rated control power supply voltage variation range is 85%-110% |
Environment |
In a medium without severe vibration and explosion hazards, and withoutgases and dust that are sufficient to corrode metals and damage insulation;In places where rain and snow cannot reach. |
Note:The controlled load is single-phase power supply, and the working current does not exceed the rated value of the machine. Direct control can be used, and the wiring method is shown in Figure 2.
Note:The controlled load is single-phase power supply, and if the working current exceeds the rated value of the machine, please use the Ac contact or coi l voltage (AC220v) expansion method. The wiring method is shown in Figure 3.
The contact or expansion control method and wiring method are shown in Figure3.