Product Overview
Product Details
Data Download
Related Products
YCHR8 series fuse-type isolating switches works with NH00 and NH01 type fuses. Has aworking voltage range of 0-500V DC and 0-690V AC with a maximum current of 800A. The working current varies according to size of fuse used.
Contact Us
• UPS for the power supply of computers and servers
• Telecommunication power supply
• Metering and lighting module applications
• Switchboards
• Capacitor banks
• General fuse for power supply networks
• Power supply and generation fuse protection
1. The ambient air temperature should not be higher than +50°C and not lower than -5°C.
2. Humidity: When the maximum temperature is +50°C, the relative humidity of the air does not exceed 50%. Higher relative humidity is allowed at lower temperatures, such as 90% at 20°C.Special measures should be taken against occasional condensation due to temperature changes.
3. The pollution level of the surrounding environment is level 3.
4. The switch should be installed in a place without significant vibration away from hazardous and flammable materials.
5. Has an IP30 rating when closed and IP20 rating when open.
YCHR8 -250 /2 | ||
Model | Shell frame current | Number of poles |
YCHR8 | 250 | 2 |
YCHR8 | 160(160~400) | 2:2P |
3:3P | ||
250(400~800) | 4:4P |
Model | YCHR8-160 | YCHR8-250 | |||||
Number of poles | 2P | 2P/3P/4P | 2P | 2P/3P/4P | |||
Rated operational voltage Ue AC (V) | / | / | 500 | 690 | / | 500 | 690 |
Rated operational voltage Ue DC (V) | 220 | 500 | / | / | 500 | / | / |
Rated operational current le (A) | 160 | 125 | 160 | 125 | 250 | 250 | 200 |
Thermal current with fuse-link Ith(A) | 160 | 160 | 160 | 160 | 250 | 250 | 250 |
Utilization category | DC22B | DC22B | ADC22B | ADC21B | DC22B | ADC22B | ADC21B |
Rated insulation voltage Ui(V) | 1000 | 1000 | |||||
Rated impulse withstand voltage Uimp (kV) | 8 | 8 | |||||
Rated conditional short circuit current (kArms) | 50 | 50 | |||||
Rated frequency (Hz) | 50/60 | 50/60 | |||||
Power loss(Ith)without fuselink,per phase (W) | 3.5 | 7.5 | |||||
Electrical durability | 200 | 200 | |||||
Mechanical durability | 1400 | 1400 | |||||
Degree of protection from the front according to IEC60529 |
IP20 | IP20 | |||||
IP30 | IP30 |
Agreed heating current (A) | Fuse link model | Rated working voltage (V) | Optional fuse(A) |
YCHR8-160 | NT00 | 1-220VDC | 4,6,10,16,20,25,32,35,40,50, 63,80,100,125,160 |
220-500VDC | 4,6,10,16,20,25,32,35,40,50, 63,80,100,125 |
||
220-400VAC | 4,6,10,16,20,25,32,35,40,50, 63,80,100,125,160 |
||
400-690VAC | 4,6,10,16,20,25,32,35,40,50, 63,80,100,125 |
||
YCHR8-250 | NT1 | 1-500VDC | 80,100,125,160,200,225,250 |
220-400VAC | 80,100,125,160,200,225,250 | ||
400-690VAC | 80,100,125,160,200,225 |