YCHR8 Fuse-type Isolation Switch
YCHR8 Fuse-type Isolation Switch
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCHR8 Fuse-type Isolation Switch
Picture
  • YCHR8 Fuse-type Isolation Switch
  • YCHR8 Fuse-type Isolation Switch

YCHR8 Fuse-type Isolation Switch

YCHR8 series fuse-type isolating switches works with NH00 and NH01 type fuses. Has aworking voltage range of 0-500V DC and 0-690V AC with a maximum current of 800A. The working current varies according to size of fuse used.

Contact Us

Product Details

Features

• UPS for the power supply of computers and servers

• Telecommunication power supply

• Metering and lighting module applications

• Switchboards

• Capacitor banks

• General fuse for power supply networks

• Power supply and generation fuse protection

Operating condition

1. The ambient air temperature should not be higher than +50°C and not lower than -5°C.

2. Humidity: When the maximum temperature is +50°C, the relative humidity of the air does not exceed 50%. Higher relative humidity is allowed at lower temperatures, such as 90% at 20°C.Special measures should be taken against occasional condensation due to temperature changes.

3. The pollution level of the surrounding environment is level 3.

4. The switch should be installed in a place without significant vibration away from hazardous and flammable materials.

5. Has an IP30 rating when closed and IP20 rating when open.

Type designation

YCHR8    -250           /2
Model    Shell frame current Number of poles
YCHR8 250 
YCHR8 160(160~400)    2:2P
   3:3P
250(400~800)    4:4P

Technical data

Switch technical parameters
Model YCHR8-160 YCHR8-250
Number of poles 2P 2P/3P/4P 2P 2P/3P/4P
Rated operational voltage Ue AC (V) / / 500  690  / 500  690 
Rated operational voltage Ue DC (V) 220  500  / / 500  / /
Rated operational current le (A) 160  125  160  125  250  250  200 
Thermal current with fuse-link Ith(A) 160  160  160  160  250  250  250 
Utilization category DC22B DC22B ADC22B ADC21B DC22B ADC22B ADC21B
Rated insulation voltage Ui(V) 1000  1000 
Rated impulse withstand voltage Uimp (kV)
Rated conditional short circuit current (kArms) 50  50 
Rated frequency (Hz) 50/60 50/60
Power loss(Ith)without fuselink,per phase (W) 3.5  7.5 
Electrical durability 200  200 
Mechanical durability 1400  1400 
Degree of protection from the front according to
IEC60529
IP20 IP20
IP30 IP30
The relationship between switches and fuses
Agreed heating current (A) Fuse link model Rated working voltage (V) Optional fuse(A)
YCHR8-160 NT00 1-220VDC 4,6,10,16,20,25,32,35,40,50,
63,80,100,125,160
220-500VDC 4,6,10,16,20,25,32,35,40,50,
63,80,100,125
220-400VAC 4,6,10,16,20,25,32,35,40,50,
63,80,100,125,160
400-690VAC 4,6,10,16,20,25,32,35,40,50,
63,80,100,125
YCHR8-250 NT1 1-500VDC 80,100,125,160,200,225,250
220-400VAC 80,100,125,160,200,225,250
400-690VAC 80,100,125,160,200,225

Overall and mounting dimensions(mm)

YCHR8-160
YCHR8-160 Fuse-type Isolating Switches Overall and mounting dimensions
 YCHR8-250
YCHR8-250 Fuse-type Isolating Switches Overall and mounting dimensions
 
Size SpecificationsOptional fuse (A)
160A 250A
A 187.5  268.5 
B 72.5  126 
D 39.7  57.3 
E 12.5  25 
F 6.8  11 
H 211.5  300 
J 88  116 
I 166  237 
N 43  66.5 