YCHGL-63~3150A Isolation Switch
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCHGL-63~3150A Isolation Switch
Picture
Video
  • YCHGL-63~3150A Isolation Switch
  • YCHGL-63~3150A Isolation Switch
  • YCHGL-63~3150A Isolation Switch
  • YCHGL-63~3150A Isolation Switch
  • YCHGL-63~3150A Isolation Switch
  • YCHGL-63~3150A Isolation Switch
YCHGL-63~3150A Isolation Switch Featured Image

YCHGL-63~3150A Isolation Switch

General
1.YCHGLZ1-125-3150A is suitable for switching two low-voltage circuits or
transforming and safely isolating two load devices
2.Operating mode:
Direct operate:handle isinstalled on theswitch
Operationoutside the cabinet handle is installedousideof distibutioncabinet door
3、3P4P(3P+breakable neutral pole)
4.It canbe used for outside-cabinet operation withlong axis
5.Two auxiliary contacts can be installed ifneeded
6.Electrical performance and mechanical performanceis as same as YCHGL-125-3150A correspondingly
7.Provide bridge type connecting conductors connected with output terminal orinput terminalof switch
PS:when using bridge type connection,please instructif it appliesto theline endor the outlet end

Contact Us

Product Details

product-description1

Service environment

1. YCHGL load-isolation switch can operate under the following conditions
2. Altitude not more than 2000m;
3. The range of ambient temperature is from -5℃ to 40℃;
4. Relative humidity not more than 95%;
5. The environment without any explosive medium.
6. The environment without any rain or snow attacking.
If the product is expected to be used in the environment where temperature is over +40℃ or below -5℃, user's shall tell it to the manufacturer

product-description2

product-description3

Conformed standard

International standard
IEC60947-1(1998)<Low-voltage switchgear and controlgear, part one: General Rules>.
IEC60947-3(1999)< Low -voltage switchgear and controlgear, switches, disconnectors, switch-disconnectors and fuse-conbination units>.

Load isolation switch of YCHGL-63~3150A

7 specifications of HGL load isolation switch from 63A to 3150A: Basic model of modularized design,3 poles,4 poles (3 poles+on and off neutral pole).It is suitable for the making and breaking operation of electric dircuit or electric isolation.Switches over 1000A are only suitable for electric isolation.
Mark window is set in the front side to indicate the on and off state of the contact.

Operation mode

1. Direct operation: The handle is installed in the middle of the switch.
2. Operation outside the board: The handle is installed outside the door off distributing board.

product-description4

product-description5 product-description6 product-description7 product-description8 product-description9

Write your message here and send it to us