YCC6 AC Contactor
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCC6 AC Contactor
Picture
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor
  • YCC6 AC Contactor

YCC6 AC Contactor

YCC6 series AC Contactor with novel appearance and compact structure is suitable for using starting & controlling the AC motor frequently, switching on and off the circuit at a long distance. It is used in combination with thermal relay to compose a magnetic motor starter.
 
Standard: lEC 60947-1, IEC 60947-4-1.

Contact Us

Product Details

YCC6-50 (45) 拷贝

General

YCC6 series AC Contactor with novel appearance and compact structure is suitable for using starting & controlling the AC motor frequently, switching on and off the circuit at a long dis-

tance. It is used in combination with thermal relay to compose a magnetic motor starter.

Standard: lEC 60947-1, IEC 60947-4-1.

 

Technical data

•    Rated operation current(le): 9-95A

•    Rated operation voltage(Ue):220V~690V

•    Rated insulation voltage: 690V

•    Poles: 3P

•    Installation: Din rail and screw installation

Type designation

Operating Conditions

 

Type

Operating Conditions

Installation category

III

Pollution degree

3

Certification

CE, CB, CCC, TUV

Protection degree

YCC6-09~38:IP20(front side);YCC6-40~95:IP10

 

Ambient temperature

Limit of temperature: -35°C~+70°C;

Normal temperature: -5°C~+40°C;

The average no more than +35°C within 24 hours;

If not in normal operating temperature range, please refer to“Instructions for abnormal environment”

Altitud

≤ 2000m

 

Ambient temperature

The maximum temperature of 70 degrees, the air relativehu-

midity not exceed 50%,under lower temperature can allowfor

higher relative humidity.If the temperature is 20°C, the air

relative humidity could upto 90%,Special measures should be

taken for occasionalcondensation due to humidity changes.

Installation position

Inclination between installation surface and vertical surface- should not exceed +5°

Shock vibration

Products should be installed and used without significantshake,shock and vibration place.

Specifications

YCC6 Specifications
Type                                                          YCC6-09 YCC6-12 YCC6-18|YCC6-25  YCC6-32 YCC6-38 YCC6-40  YCC6-50  YCC6-65|YCC6-80 YCC6-95
Main   circuit   characteristic
Poles 3P
Rated insulation voltage(Ui) V 690 
Rated operating voltage(Ue) V 220/230,380/400,660/690
Rated thermal current(lth),AC-1 20  20  32  40  50  50  60  80  80  125  125 
Rated
operation
current(le)
AC-3,380/400V A 12  18  25  32  38  40  50  65  80  95 
AC-3,660/690V A 6.6  8.9  12  18  22  22  34  39  42  49  49 
AC-4,380/400V A 3.5  7.7  8.5  12  14  18.5  24  28  37  44 
AC-4,660/690V A 1.5  3.8  4.4  7.5  8.9  12  14  17.3  21.3 
Rated
operational
power(Pe)
AC-3,380/400V kW 5.5  7.5  11  15  18.5  18.5  22  30  37  45 
AC-3,660/690V kW 5.5  7.5  10  15  18.5  18.5  30  33  37  45  45 
AC-4,380/400V kW 1.5  2.2  3.3  5.4  5.5  7.5  11  15  18.5  22 
AC-4,660/690V kW 1.1  1.5  3.7  5.5  7.5  10  11  15  18.5 
Mechanical life 10000
times
1200  1000  900  650 
Electrical life AC-3 110  90  65 
AC-4 22  22  17  11 
Frequency
of operation
AC-3 fmes/
hour
1200  600 
AC-4 300  300 
Connecting capability of main circuit terminal
Flexible wire wire mm² 1.56  2.5  4...50
No terminal 2 wire mm2 1...4 1.5...6 2.5...16 4...25
Flexible wire 1 wire mm2 1...4 1...6 2.5...25 4...50
With terminals 2 wire mm² 1...2.5 1...4 2.5...10 4...16
Hard wire 1 wire mm² 1..4 1.5...6 1.5...10 2.5...25 4...50
No terminal 2 wire mm² 1...4 1.5.. 2.5...10 4...25
Fastening torque N ·m 1.2  1.8 
Coil
Rated control
voltage(Us)
50Hz V 24,36,48,110,127,220/230,240,380/400,415,440
50/60Hz V 24,36,48,110,127,220/230,240,380/400,415,440
Allowed control
circuit
voltage(Us)
Operation V Installation inclination angle ±22.5°:85%~110%Us;Installation inclination angle±5°:70%~120%
Release V Installation inclination angle ±22.5°:20%~75%Us;Installation inclination angle±5°:20%~65%
Power
consumption
ofcoil
Actuation VA 60  70  200  200 
Keep VA 6-9.5 6-9.5 15-20 15-20
Consumption W 1-3 1-3 6-10 6-10
Auxiliary contacts
Auxiliary contacts specification A 1NO+1NC
Rated thermal current (lth) A 10 
Rated operating
voltage  (Ue)
AC V 380 
DC V 220 
Rated control
capacit
AC-15 VA 360 
DC-13 W 33 
Certification CCC,CE,TUV,CB

Type

A max

B max

B max

a

b

c

d

e

f

YCC6-09, 12, 18

74.5

45.5

85.5

35

50/60

-

-

-

-

YCC6-25, 32, 38

83

56.5

97

40

50/70

-

-

-

-

YCC6-40, 50, 65

127.5

74.5

117

-

-

105

40

100/110

59

YCC6-80, 95

127.5

85.5

125.5

-

-

105

40

100/110

67

F4-D.LA2-D,LA3-D Contact Block

Type

Product

Configuration of contacts

Number of N/o contact

Number of N/c contact

 

 

F4-DN20 F4-DN11 F4-DN02

 

 

 

2

1

0

 

 

0

1

2

 

F4-DN40 F4-DN31 F4-DN22 F4-DN13 F4-DN04

 

 

 

4

3

2

1

0

 

0

1

2

3

4

Type

 

Time-delay range

Number of time-delay contacts

 

 

LA2-DTO LA2-DT2 LA2-DT4

 

 

 

 

0.1S~3S  0.1S~30S 10S~180S

 

 

 

1NO+1NC

 

 

LA3-DRO LA3-DR2 LA3-DR4

 

 

 

 

0.1S~3S  0.1S~30S 10S~180S

 

 

 

1NO+1NC

LX1-D Coil

 

Type

 

A max

Coil voltage Us(V)

Frequency (Hz)

 

24

 

36

 

42

 

48

 

110

 

127

 

220

 

230

 

240

 

380

 

400

 

415

 

400

 

600

 

LX1-D2

 

 

 

50Hz

 

B5

 

C5

 

D5

 

E5

 

F5

 

G5

 

M5

 

P5

 

U5

 

Q5

 

V5

 

N5

 

R5

 

X5

 

LX1-D4

 

 

 

60Hz

 

B6

 

C6

 

D6

 

E6

 

F6

 

G6

 

M6

 

P6

 

U6

 

Q6

 

V6

 

N6

 

R6

 

X6

 

LX1-D6

 

 

 

50/60Hz

 

B7

 

C7

 

D7

 

E7

 

F7

 

G7

 

M7

 

P7

 

U7

 

Q7

 

V7

 

N7

 

R7

 

X7

 

Specifications

Type

Rated operation current(Ie)(A)

Rated thermal cur-

rent (Ith)(A)

Rated operational power in category AC-3 (kW)

380V

660V

YCC6-09N

9

20

4

5.5

YCC6-12N

12

20

5.5

7.5

YCC6-18N

18

32

7.5

10

YCC6-25N

25

40

11

15

YCC6-32N

32

50

15

18.5

YCC6-38N

38

50

15

18.5

YCC6-40N

40

50

18.5

30

YCC6-50N

50

60

22

33

YCC6-65N

65

80

30

37

YCC6-80N

80

95

37

45

YCC6-95N

95

95

45

55

Overall and mounting dimensions(mm)

YCC6-09~38N

YCC6-40~95N

Type

A max

B max

B max

a

b

c

d

e

f

YCC6-09, 12, 18

74.5

45.5

85.5

35

50/60

-

-

-

-

YCC6-25, 32, 38

83

56.5

97

40

50/70

-

-

-

-

YCC6-40, 50, 65

127.5

74.5

117

-

-

105

40

100/110

59

YCC6-80, 95

127.5

85.5

125.5

-

-

105

40

100/110

67