General
1.Protection against the effects of sinusoidal alternating earth fault currents
2.Protection against indirect contacts and additional protection against direct contacts
3.Protection against fire hazard caused byinsulation faults
4.Controlling and Switching
5.Used in residential building,non-residential building,energysources,industryand infrastructure

Contact Us

Product Details

Responsive 3D Model
YCB9RL-100-product-description1

General

1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure

Release

Type Tripping sensitivity data
AC For residual sinusoidal alternating currents 30mA For personnel,material and fire protection,as well as Tor protection against airect contact
A For residual sinusoidal alternating currents and residual pulsating direct currents 100mA For providing protection against indirect contacts
S For selectivity,with time delay 300mA For providing fire protection in case of insulation faults

Wiring Diagram

YCB9RL-100-product-description3

Specifications

Overall and Mounting Dimensions (mm)

Type Standard IEC/EN 61008-1
Electrical features Leakage type Electromagnetic type
Rated current In A 16,25,32,40,50,63,80,100
Type (wave form of the earth leakage sensed) A,AC
Poles P 1P+N,3P+N
Rated voltage Ue V 230/400
Insulation voltage Ui V 500
Rated frequency Hz 50/60
Rated breaking capacity Inc=l4c A 600,010,000
Rated impulse withstand voltage (1.2/50)Uimp V 6000
Dielectric test voltage at ind.Freq.for 1min kV 2.5
Rated sensitivity I△n A 0.03,0.1,0.3
Rated residual making and breaking capacity l-m A 500(ln≤40A);630(In=50A/63A);1000(In=80A/100A)
Pollution degree
Electrical life t 4000
Mechanical features Mechanical life t 8000
Protection degree IP20
Storage temperature -25~+70
Ambient temperature(with daily average≤35℃) -5~+40
Terminal connection type Cable/Pin-type busbar/U-type busbar
Installation Terminal size top /bottom for cable mm² 25/35
AWG 18-3/18-2
Terminal size top /bottom for busbar mm² 10月16日
AWG 18-8/18-5
Tightening torque N*m 2.5
In-Ibs 22
Mounting On DIN rail EN 60715(35mm)by means of fast clip
Connection From top or bottor