CJX2S-M AC contactor
  • Pangkalahatang -ideya ng produkto

  • Mga detalye ng produkto

  • Pag -download ng data

  • Mga kaugnay na produkto

CJX2S-M AC contactor
Larawan
Video
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
  • CJX2S-M AC contactor
Itinampok ng CJX2S-M AC contactor ang imahe

CJX2S-M AC contactor

Pangkalahatang -ideya ng produkto

Ang serye ng CJX2S-M AC contactor na may hitsura ng nobela at compact na istraktura ay angkop para sa paggamit ng pagsisimula at pagkontrol ng AC motor, madalas na lumipat at off ang circuit sa isang mahabang distansya. Ginagamit ito sa pagsasama sa thermal relay upang magsulat ng isang magnetic motor starter.

Pamantayan: IEC 60947-1, IEC 60947-4-1.

Makipag -ugnay sa amin

Mga detalye ng produkto

Tumutugon na modelo ng 3D

Pangkalahatang -ideya ng produkto

Ang serye ng CJX2S-M AC contactor na may hitsura ng nobela at compact na istraktura ay angkop para sa paggamit ng pagsisimula at pagkontrol ng AC motor, madalas na lumipat at off ang circuit sa isang mahabang distansya. Ginagamit ito sa pagsasama sa thermal relay upang magsulat ng isang magnetic motor starter.

Pamantayan: IEC 60947-1, IEC 60947-4-1.

Modelo at kahulugan

Mga pagtutukoy

Rated Operation Kasalukuyang (IE): 6-16a ;
Rated Operation Voltage (UE): 220V ~ 690V ;
Na -rate na boltahe ng pagkakabukod: 690V ;
Mga Poles: 3P 、 4P ;
Pag -install: Pag -install ng tren at tornilyo
I -type Mga kondisyon sa pagpapatakbo at pag -install
Kategorya ng pag -install III
Antas ng polusyon 3
Sertipikasyon CE, CB, CCC, TUV
Degree sa proteksyon IP20
Nakapaligid na temperatura Limitasyon ng temperatura: -35 ℃ ~+70 ℃, normal na temperatura: -5 ℃ ~+40 ℃, ang average na hindi hihigit sa+35 ℃ sa loob ng 24 na oras.Kung hindi sa normal na saklaw ng temperatura ng operating, mangyaring sumangguni sa "mga tagubilin para sa hindi normal na kapaligiran"
Taas ≤2000m
Nakapaligid na temperatura Ang maximum na temperatura ng 70 degree, ang kahalumigmigan na kahalumigmigan ng hangin ay hindi lalampas sa 50%, sa ilalim ng Lowertemperature ay maaaring payagan ang mas mataas na kamag -anak na kahalumigmigan.Kung ang temperatura ay 20 ℃, ang hangin na kamag -anak na kahalumigmigan hanggang sa 90%, ang mga espesyal na hakbang ay dapat na betakor para sa paminsan -minsang mga pagbabago sa kahalumigmigan ng due ng due.
Posisyon ng pag -install Ang pagkahilig sa pagitan ng ibabaw ng pag -install at patayong ibabaw ay hindi dapat lumampas sa ± 5 °
Shock Vibration Ang mga produkto ay dapat na mai -install at magamit nang walang pag -iling, pagkabigla at lugar ng panginginig ng boses.

 

Hitsura

 
I -type CJX2S-M06 CJX2S-M09 CJX2S-M12 CJX2S-M16
Mga Poles 3P/4P
Na -rate na boltahe ng pagkakabukod (UI) V 690
Rated Operating Voltage (UE) V 380/400, 660/690
Na -rate na thermal kasalukuyang (ith)AC-1 20
Ratedoperation kasalukuyang (IE) AC-3,380/400V A 6 9 12 16
AC-3,660/690V A 3.8 4.9 4.9 4.9
AC-4,380/400V A 6 9 9 12
AC-4,660/690V A 3.8 4.9 4.9 4.9
Rated Operational Power (PE) AC-3,380/400V kW 2.2 4 5.5 7.5
AC-3,660/690V kW 3 4 4 4
Mekanikal na buhay 10000 beses 1200
Buhay ng Elektriko AC-3 120
AC-4 Tingnan ang curve ng elektrikal na buhay
Frequencyof Operation AC-3 beses/ oras 1200
AC-4 300

 

Nababaluktot na kawad 1 wire mm² 1 ... 4
Walang terminal 2 wire mm² 1 ... 4
Nababaluktot na kawad 1 wire mm² 1 ... 4
Na may mga terminal 2 wire mm² 1 ... 2.5
Hard wire 1 wire mm² 1 ... 4
Walang terminal 2 wire mm² 1 ... 4
PASTING TORQUE N · m 1.2
Coil
Rated Control Voltage (US) 50Hz V 24、36、48、110、127、220、380、415
50/60Hz V 24、36、48、110、127、220、380、415
DC V 12、24、36、48、110、127、220
Pinapayagan ang Control Circuit Voltage (US) Operasyon V Anggulo ng Pag -install ng Pag -install ± 22.5 °: 85%~ 110%US ; Anggulo ng Pag -install ng Pag -install ± 5 °: 70%~ 120%
Paglabas (AC) V Anggulo ng Pag -install ng Pag -install ± 22.5 °: 20%~ 75%US ; Anggulo ng Pag -install ng Pag -install ± 5 °: 20%~ 60%
Paglabas (DC) V Anggulo ng Pag -install ng Pag -install ± 22.5 °: 10%~ 75%US ; Anggulo ng Pag -install ng Pag -install ± 5 °: 10%~ 60%
Ang pagkonsumo ng kuryente ng coil Actuation VA 20-40
Panatilihin VA 9.5

Pagkonsumo

W 1-3

 

Pagtukoy sa Mga Pakikipag -ugnay sa Auxiliary A 1no/1nc
Na -rate na thermal kasalukuyang (ith) A 10
Rated Operating Voltage (UE) AC V 380/400
DC V 220
Na -rate na control capacit AC-15 VA UE/IE: AC380V/400V/1. 5A IT H: 10A
DC-13 W Ue/ie: dc220v/0. 3a

Pangkalahatan at pag -mount

I -type Amax Bmax Cmax Dmax a b Φ
CJX2S-M06-M16 45.5 59 58 94 35 ± 0.35 50 ± 0.48 4.2

CJX2S-M06/Z-M16/Z.

45.5 59 70 106 35 ± 0.35 50 ± 0.48 4.2

I -type Amax Bmax Cmax Dmax a b Φ
CJX2S-M06/N-M16/N. 91 59 58 94 80 ± 0.35 50 ± 0.48 4.2
CJX2S-M06/Z/N-M16/Z/N. 91 59 70 106 35 ± 0.35 50 ± 0.48 4.2

 

CJX2S-M AC contactor ng talahanayan ng pagpili

Power Power KW Maximum na operasyon kasalukuyang a Bilang ng mga contact na nilalaman sa katawan ng contactor Modelong contactor
380V/400V 660V/690V (AC-3 380V/400V) NO NC
2.2 3 6 1 0 CJX2S-M0610
2.2 3 6 0 1 CJX2S-M0601
2.2 3 6 0 0 CJX2S-M0604
2.2 3 6 0 0 CJX2S-M0608
4 4 9 1 0 CJX2S-M0910
4 4 9 0 1 CJX2S-M0901
4 4 9 0 0 CJX2S-M0904
4 4 9 0 0 CJX2S-M0908
5.5 4 12 1 0 CJX2S-M1210
5.5 4 12 0 1 CJX2S-M1201
5.5 4 12 0 0 CJX2S-M1204
5.5 4 12 0 0 CJX2S-M1208
7.5 4 16 1 0 CJX2S-M1610
7.5 4 16 0 1 CJX2S-M1601
7.5 4 16 0 0 CJX2S-M1604
7.5 4 16 0 0 CJX2S-M1608

CJX2s-Mac Contactor Coil boltahe Specication mesa

AC (v) 50Hz 24 36 48 110 127 220 380 415
AC (V) 60Hz 24 36 48 110 127 220 380 415
AC (v) 50/60Hz 24 36 48 110 127 220 380 415
DC (V) 12 24 36 48 110 127 220 -

Mga tagubilin para sa paggamit ng mga kadahilanan sa pagwawasto in Mataas na altItude area

Altitude (m) 2000 3000 4000
Na -rate na salpok na may kapansin -pansin na kadahilanan ng pagwawasto ng boltahe 1 0.88 0.78
Na -rate na operasyon ng kasalukuyang kadahilanan ng pagwawasto 1 0.92

Mga tagubilin para sa Gumamit sa ilalim ng abnormal ambient temperatura

Nakapaligid na temperatura (℃) 55 60 65 70
Kadahilanan ng pagwawasto 1 0.93 0.875 0.75