Rated voltage:HV equipment 7.2KV and 12KV,LV equipment 0.4 KV.Rated current:HV equipment 630A,LV equipment 100-2000A.Aplication:YBM22 seriessubstation is a kind of compactpower distribution device that integrates high and low voltageelectrical equipment.It can be used in high-risebuildings,buildings in urban and rural areas,residential communities,high-techdevelopment areas,small and medium size factories,miningareas,oilfields,temporary features sites,and other premises.It alsocan beused for acceptance and distribution of power in power distribution system of 6-15KV,50HZ(60HZ),ring main powerdistribution system and double power supply or radiate terminal power distribution system.
Rated voltage:HV equipment 7.2KV and 12KV,LV equipment 0.4 KV.Rated current:HV equipment 630A,LV equipment 100-2000A.Application:YBM22 series substation is a kind of compact power distribution devicethatintegrates high and low voltageelectrical equipment.It can be used in high-rise buildings,buildings in urbanand rural areas,residential communities,high-techdevelopment areas,small and medium size factories,mining areas,oil fields,temporary features sites,and other premises.It alsocan beused for acceptance and distribution of powerin power distribution system of 6-15KV,50HZ(60HZ),ring main powerdistribution system and double power supply or radiate terminal power distribution system.
Rating
Rated voltage :HVequipment10KV and 12K,LV equipment 0.4 KVRated current HV equipment 630A,LVequipment 1500A.
KWN61-40.5 Air insulated metal dadmowable switchgear is an indoor switdhgear,assembly operating under theconditions of50/60Hz three phaseand rated 40.5kV AC voltage,which is applied to the transmission anddistribution for gene ators.transformer substations and the industy and mine enterprises It also can be used to control,protect and monitor electicdircuits,and very usefulfor fiequent operating condition
Standard IEC62271-200
KYN28A-12 indoor metal clad movable switchgear is a complete power distribution device for 3.6kV~12KV,3 phase AC 50/60Hz,single bus sectionalized system.It is mainly used for power transmissionof middle/smallgenerators in power plants,powerreceiving,transmission for substations in power distribution and power system of factories,mines and enterprises etc.so as tocontrol,protectand monitor the system.
Standard.IEC62271-200
Rating
Rated voltage 12/24KV,rated current reachto 630A.
Application:
mainly applicable in urban power grid features and renovation project,industrialand mining enterprises,high-rise buildings andcommunal facilities.For power distribution,controlling and protection on electric equipment as the looppower supply unit orterminal equipment.It also can be installed in pre-loaded substation
Rating:Rated voltage:380V. 50-60Hz
Application:
mainly applicable in power station,power substation industrial and mining enterprises as energy converter,distributor and controller of power,light and distribution device.
Standard:IEC60439-1
Application:mainly applicable in places with high automation andneed to communicate with computer like large power stationand petrochemistry system,as the low voltage distribution device of the distribution and motor controling,and reactive powercompensationin power system.
MNS low-voltage withdrawable switchgear is suitablefor power systems with an AC 50Hzand a rated working voltage of 400V.Itis mainly used for energy conversion,distribution,and control of distribution equipment.
Mainly suitable for airports,power stations,transportation and energy,industrial and mining enterprises,residential communities.and other places.
Standard:IEC439
The XL-21 low voltage powerdistributioncabinet issuitable for three-phase four-wire systems with ACvoltages up to 500V.It isprimarily used for power distribution purposes in power plants,industrial and mining enterprises,high-rise buildings,andotheroccasions
The XL-21 low-voltage power distribution cabinet is securely wall-mountedand allows for front-panel maintenance and inspection.
Operating conditions
1.Installation Site:Indooror outdoor;
2.Atitude:No more than 2000m.
3.Earthquake Intensity:No more than 8degrees.
4.Ambient Temperature:No more than +40℃andno lessthan-25℃Averagetemperature is no more than +35℃within 24 hours.
5.Relative Humidity:the average daily value is no more than 95%,the averagemonthlyvalue is no more than 90%
6.Installation locations:without fire,explosion danger,serious pollution,chemical corrosion and violentvibration.