Uteuzi | ||||||||||
Ycm8 | 250 | S | HU | / | 3 | 125a | AC800 | |||
Mfano | Sura ya ganda sasa | Kuvunja Uwezo | Bidhaa aina | / | Nambari ya miti | Ilipimwa sasa | Ilipimwa voltage | |||
Ycm8 | 250 (63 ~ 250) 320 (250 ~ 320) 400 (225 ~ 400) 630 (500 ~ 630) 800 (700 ~ 800) | S: Kuvunja kwa kiwango N: Kuvunja juu | HU: AC ya juu voltage | / | 3 | 63,80,100,125 140,160,180 200,225,250 280,315,320 350,400,500 630,700,800 | AC800 AC1140 | |||
Sheria za uteuzi wa nyongeza | ||||||||||
Ycm8 | MX | 1 | AC230V | |||||||
Mfano | Vifaa | Adapta Sura ya ganda | Nyongeza voltage | |||||||
Ycm8 | Ya: mawasiliano ya msaidizi MX: Kutolewa kwa shunt SD: moduli ya kengele Z: Utaratibu wa operesheni ya mwongozo P: Utaratibu wa uendeshaji wa umeme TS2: Shield ya terminal 2p TS3: Shield ya terminal 3p | 1: 250/320 2: 400/630/800 | MX: AC110V AC230V AC400V DC24V | P: AC400V AC230V DC220V |
Takwimu za kiufundi
Mfano | YCM8- 250HU | YCM8- 320HU | Ycm8- 400hu | |||||||||||||||||||||||
Kuonekana |
|
|
| |||||||||||||||||||||||
Sura ya Shell ya sasa (A) | 250 | 320 | 400 | |||||||||||||||||||||||
Idadi ya miti ya bidhaa |
|
| 3 | |||||||||||||||||||||||
Voltage ya kufanya kazi ya AC (V) | 415 | 690 | 800 | 1140 | 415 | 690 | 800 | 1140 | 415 | 690 | 800 | 1140 | ||||||||||||||
Voltageui iliyokadiriwa (V) | AC1150 | AC1150 | AC1150 | |||||||||||||||||||||||
Uhamasishaji uliokadiriwa kuhimili UIMP ya voltage (KV) | 8 | 8 | 12 | |||||||||||||||||||||||
Imekadiriwa sasa katika (a) | 63, 80, 100, 125, 140, 160, 180, 200, 225, 250 |
280, 315, 320 | 225, 250, 315, 350, 400 | |||||||||||||||||||||||
Mzunguko mfupi wa mwisho Kuvunja uwezo ICU (KA) | S | 85 | 50 | 36.5 | 10 | 85 | 50 | 36.5 | 10 | 85 | 50 | 36.5 | 10 | |||||||||||||
N | / | / | 100 | 60 | 50 | 15 | ||||||||||||||||||||
Kuendesha Uwezo wa Kuvunja Uwezo wa Mzunguko mfupi (KA) | ICS = 100%ICU | |||||||||||||||||||||||||
Njia ya wiring | Juu ndani na nje, chini ndani na nje, chini ndani na nje, juu na chini (3p) | |||||||||||||||||||||||||
Kazi ya kutengwa | Ndio | |||||||||||||||||||||||||
Aina ya kusafiri | Aina ya mafuta ya mafuta | |||||||||||||||||||||||||
Maisha ya Umeme (Wakati) | 3000 | 3000 | 2000 | 3000 | 3000 | 2000 | 1000 | 1000 | 700 | |||||||||||||||||
Maisha ya Mitambo (Wakati) | 20000 | 20000 | 10000 | |||||||||||||||||||||||
Kiwango | IEC/EN60947-2 | |||||||||||||||||||||||||
Vifaa vilivyoambatanishwa | Shunt 、 Alarm 、 Msaidizi 、 Operesheni ya Mwongozo 、 Operesheni ya Umeme | |||||||||||||||||||||||||
Udhibitisho | CE | |||||||||||||||||||||||||
Kwa jumla Vipimo (mm) |
|
| Upana (W) | 107 | 107 | 182 | ||||||||||||||||||||
Urefu (H) | 180 | 180 | 250 | |||||||||||||||||||||||
Kina (d) | 126 | 126 | 165 |
Kumbuka: ① 2p unganisho katika safu, ② 3p unganisho katika safu
Takwimu za kiufundi
Mfano | YCM8-630HU | YCM8-800HU | |||||||||||||||||
Kuonekana | | | |||||||||||||||||
Sura ya Shell ya sasa (A) | 630 | 800 | |||||||||||||||||
Idadi ya miti ya bidhaa | 3 | 3 | |||||||||||||||||
Voltage ya kufanya kazi ya AC (V) | 415 | 690 | 800 | 1140 | 415 | 690 | 800 | 1140 | |||||||||||
Voltageui iliyokadiriwa (V) | AC1150 | AC1150 | |||||||||||||||||
Uhamasishaji uliokadiriwa kuhimili UIMP ya voltage (KV) | 12 | 12 | |||||||||||||||||
Imekadiriwa sasa katika (a) |
500, 630 |
630,700, 800 | |||||||||||||||||
Mzunguko mfupi wa mwisho Kuvunja uwezo ICU (KA) | S | 85 | 50 | 36.5 | 10 | 85 | 50 | 36.5 | 10 | ||||||||||
N | 100 | 60 | 50 | 15 | 100 | 60 | 50 | 15 | |||||||||||
Kuendesha Uwezo wa Kuvunja Uwezo wa Mzunguko mfupi (KA) | ICS = 100%ICU | ||||||||||||||||||
Njia ya wiring | Juu ndani na nje, chini ndani na nje, chini ndani na nje, juu na chini (3p) | ||||||||||||||||||
Kazi ya kutengwa | Ndio | ||||||||||||||||||
Aina ya kusafiri | Aina ya mafuta ya mafuta | ||||||||||||||||||
Maisha ya Umeme (Wakati) | 1000 | 1000 | 1000 | 700 | 1000 | 1000 | 1000 | 700 | |||||||||||
Maisha ya Mitambo (Wakati) | 5000 | 5000 | |||||||||||||||||
Kiwango | IEC/EN60947-2 | ||||||||||||||||||
Vifaa vilivyoambatanishwa | Shunt 、 Alarm 、 Msaidizi 、 Operesheni ya Mwongozo 、 Operesheni ya Umeme | ||||||||||||||||||
Udhibitisho | CE | ||||||||||||||||||
Kwa jumla Vipimo (mm) |
|
| Upana (W) | 182 | 182 | ||||||||||||||
Urefu (H) | 250 | 250 | |||||||||||||||||
Kina (d) | 165 | 165 |
Vifaa
Nambari ya nyongeza | Jina la nyongeza | 250/320hu | 400/630/800hu | |
SD | Mawasiliano ya kengele |
|
| |
|
|
|
| |
MX | Kutolewa kwa shunt |
|
| |
|
|
|
| |
OF | Mawasiliano msaidizi (1no1nc) |
|
| |
Ya+ya | Mawasiliano msaidizi (2no2nc) |
|
| |
|
|
|
| |
Mx+ya | Kutolewa kwa Shunt+ Mawasiliano ya Msaada (1NO1NC) |
|
| |
|
|
|
| |
Ya+ya | Seti 2 za anwani za msaidizi (2NO2NC) |
|
| |
MX+SD | Kutolewa kwa Shunt + Alarm |
|
| |
|
|
|
| |
Ya+SD | Mawasiliano ya Msaada + Alarm Mawasiliano |
|
| |
|
|
|
| |
MX+ya+SD | Kutoa mawasiliano ya msaidizi (1NO1NC)+ mawasiliano ya kengele |
| ||
Ya+ya+SD | Seti 2 za anwani za msaidizi (2NO2NC)+anwani ya kengele |
|
|
Msaidizi wasiliana
Wasiliana na vigezo vya sasa
Iliyokadiriwa sasa ya daraja la sura ya ganda | Kukubaliana kupokanzwa sasa | Ilikadiriwa kufanya kazi sasa katika AC 400V |
Inm <320 | 3A | 0.30a |
Inm> 400 | 6A | 0.40a |
Mawasiliano ya msaidizi na mchanganyiko wake
Wakati mvunjaji wa mzunguko yuko katika nafasi ya "kuzima" | F12 F14 F22 F24 |
| F11 F21 |
F12 F14 |
|
F11 | |
Wakati mvunjaji wa mzunguko yuko katika msimamo wa "ON" | F12 F14 | F11 | |
F22 F24 | F21 | ||
F12 F14 |
| F11 |
Mawasiliano ya kengele
Kuwasiliana na kengele na mchanganyiko wake
Alarm Mawasiliano UE = 220V, ith = 3a |
| ||
Wakati mvunjaji wa mzunguko yuko kwenye msimamo wa "Off" na "ON" | B14 B14 |
| B11 |
Wakati mvunjaji wa mzunguko yuko katika nafasi ya "safari ya bure" |
B14 B12 |
|
B11 |
Shunt Kutolewa
Kwa ujumla imewekwa katika awamu A ya mvunjaji wa mzunguko, wakati voltage ya nguvu ya kudhibiti ni kati ya 70% - 110%, shunt releaseshall hufanya safari ya mvunjaji wa mzunguko kwa uhakika chini ya hali zote za kufanya kazi.
Voltage ya Udhibiti: Kawaida: AC 50Hz, 110V, 230V, 400V, DC 24V.
Kumbuka: Wakati usambazaji wa umeme wa mzunguko wa kudhibiti ni DC24V, takwimu ifuatayo inapendekezwa kwa muundo wa mzunguko wa kudhibiti shunt.
KA: DC24V ya kati, wasiliana na uwezo wa sasa ni 1A
K: Microswitch katika safu na coil ndani ya misaada ya kutolewa ni mawasiliano ya kawaida yaliyofungwa. Wakati mvunjaji wa mzunguko amekataliwa, mawasiliano yatakata moja kwa moja na kufunga wakati imefungwa.
Mchoro wa Wiring
Ufungaji njia na oveRall mwelekeo wa vifaa vya nje
Mfano na uainishaji wa mfumo wa kushughulikia wa kushughulikia
Mfano | Vipimo vya usanikishaji (mm) | Thamani ya kati ya ushughulikiaji wa kazi ya jamaa na mvunjaji wa mzunguko (mm) | |||
A | B | H | D | ||
YCM8-250/320HU | 157 | 35 | 55 | 50-150 | 0 |
YCM8-400/630/800HU | 224 | 48 | 78 | 50-150 | ± 5 |
Mchoro wa schematic wa ufunguzi wa shimo la kushughulikia kazi inayozunguka
Kwa jumla na Kuweka Dimensioni ya vifaa vya nje
Mfano na uainishaji wa mfumo wa kushughulikia wa kushughulikia
Mfano | H | B | B1 | A | A1 | D |
YCM8-250/320HU | 188.5 | 116 | 126 | 90 | 35 | 4.2 |
YCM8-400/630/800HU | 244 | 176 | 194 | 130 | 48 | 6.5 |
Mfano |
L | A |
B |
C | E | ||
Bila kifuniko cha sifuri | Na kifuniko cha sifuri | Bila kifuniko cha sifuri | Na kifuniko cha sifuri | ||||
YCM8-250HU | 40 | 100 | 165 | 40 | 40 | 100 | 165 |
YCM8-320HU | 40 | 100 | 165 | 40 | 40 | 100 | 165 |
YCM8-400HU | 40 | 100 | 165 | 40 | 40 | 100 | 165 |
YCM8-630HU | 40 | 100 | 165 | 40 | 40 | 100 | 165 |