Single output power supply
Summary
single output: power 150W
Input voltage: 90~132VAC/180~264VAC by switch
Contact Us
S-150W
Single output: power 150W
Input voltage: 90~132VAC/180~264VAC by switch
Model Specification |
S-150-5 | S-150-12 | S-150-15 | S-150-24 | S-150-36 | S-150-48 |
DC output voltage, current | 5V 0~30A | 12V0~12.5A | 15V0~10A | 24V0~6.5A | 36V0~4.1A | 48V0~3.1A |
Wave and noise | 150mVp-p | 180mVp-p | 180mVp-p | 240mVp-p | 240mVp-p | 240mVp-p |
Inlet wire stability | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
Load stability | ±0.8% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
Efficiency | 78% | 82% | 84% | 85% | 86% | 87% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
Input voltage range | 90~132VAC/180~264VAC by switch 254~370VDC 47~63Hz | |||||
Impact current | Cold start current 35A/115VAC 60A/230VAC | |||||
Overload protection | 105%~150% cut off the output, automtic recovery | |||||
Over voltage protection | 115%~135% shut down O/P voltage ,re-power on to recover | |||||
Setup, rise, hold up time | 100ms, 50ms, 20ms/230VAC at full load | |||||
Withstand voltage | I/P-O/P: 1.5kV I/P-FG: 1.5kV O/P-FG: 0.5kV 1minute | |||||
Isolation resistance | I/P-O/P I/P-FG O/P-F/G: 500VDC/100MΩ | |||||
Working temperature | -10℃~+50℃ | |||||
Dimension | 199×110×50mm |
S-200W
Single output: power 200W
Input voltage: 180~264VAC by switch
Model Specification |
S-200-5 | S-200-12 | S-200-15 | S-200-24 | S-200-36 | S-200-48 |
DC output voltage, current | 5V 0~40A | 12V0~16A | 15V0~13A | 24V0~8.5A | 36V0~5.5A | 48V0~4.2A |
Wave and noise | 150mVp-p | 180mVp-p | 180mVp-p | 240mVp-p | 240mVp-p | 240mVp-p |
Inlet wire stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 79% | 82% | 83% | 83% | 86% | 86% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
Input voltage range | 90 ~ 132VAC/ 180 ~264VAC | |||||
Impact current | Cold start current 15A/115VAC 30A/230VAC | |||||
Overload protection | 105%~201% cut off the output, automtic recovery | |||||
Over voltage protection | ||||||
Setup, rise, hold up time | 200ms, 50ms, 20ms/230VAC at full load | |||||
Withstand voltage | I/P-O/P: 1.5kV I/P-FG: 1.5kV O/P-FG: 0.5kV 1minute | |||||
Isolation resistance | I/P-O/P I/P-FG O/P-F/G: 500VDC/100MΩ | |||||
Working temperature | -10℃~+50℃ | |||||
Dimension | 199×110×50mm |