S□-35KV Series Oil-Immersed Transformer.
Picture
  • S□-35KV Series Oil-Immersed Transformer.
  • S□-35KV Series Oil-Immersed Transformer.

S□-35KV Series Oil-Immersed Transformer.

1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln, type D(10-20)ln

Conatct Us

Product Details

S□-35KV Series Non-excitation Voltage Regulating Transformer

This kind of product is applied to power system of three-phase, 50Hz as well as 35kV and below,is the main transformer equipment of medium and small-sized transformer substation, supplies power distribution, power and illumination for the industry and agriculture.

The company introduces in domestic and overseas advanced technique, adopts the latest material and optimizes design, which enables the product structure more reasonable, and greatly improves the product electric strength, mechanical strength and heat- sinking capability.

Standard

0

Operating conditions

1. Altitude: ≤1000m.

2. Ambient temperature: the highest temperature +40℃,the highest monthly average temperature +30℃; The highest yearly average temperature +20℃ .

3. Installation environment: inclination of installation place<3°, no obvious dirt and corrosive or flammable gas.

 Features

1. Iron core:

The iron core is made of high-quality cold-rolled silicon steel sheet, and adopts various forms such as fully biased multi-stage joints, without punch holes, wind cores, etc., and clamp them with stainless steel stays and epoxy glass tapes.

2. Coil:

The conductor is made of high-quality oxygen-free copper enameled wire or paper-wrapped flat copper wire, and the coil is made of drum type, spiral type, improved spiral type, continuous type, staggered type and other types.

3. Oil tank:

The oil tank is barrel type or shielded type, and the heat dissipation element adopts corrugated plate or electroplating radiator.The transformer is not equipped with a trolley, but a base that conforms to the national standard gauge is welded on the bottom of the box for your convenience.

4. Safety protection device:

According to national standards and user requirements, the transformer can be equipped with the following safety protection devices:pressure relief valve, gas relay, signal thermometer, oil filter, oil conservator, oil sample valve, etc.

S9-50~1600/35KV technical data

Rated
capacity
(kVA)
Voltage combination Connection symbol No-load loss(W) Load   loss(W) No-load
current
(%)
Short circuit
impedance
(%)
(kV)H.V Tapping range of high voltage L.V
(kV)
50 35 ±5% 0.4 Dyn11
Yyn0
210 1270/1210 2 6.5
100 290 2120/2020 1.8
125 340 2050/2380 1.7
160 360 2970/2830 1.6
200 430 3500/3330 1.5
250 510 4160/3960 1.4
315 610 5010/4770 1.4
400 730 6050/5760 1.3
500 860 7280/6930 1.2
630 1040 8280 1.1
800 1230 9900 1
1000 1440 12150 1
1250 1760 14670 0.9
1600 2120 17550 0.8

Note:The table above the load loss in the value of a slash aply to Dynll or znl1 coecin group, slash the botom of the load os values for Yyn0 connection group

S9-800~31500/35KV technical data

Rated
capacity
(kVA)
Voltage combination Connection symbol No-load loss(W) Load   loss(W) No-load
current
(%)
Short circuit
impedance
(%)
(kV)H.V Tapping range of high voltage L.V
(kV)
800 35 ±5%
±2×2.5%
3.15
3.3
6.3
6.6
10.5
Yd11 1250 9900 1.05 6.5
1000 1480 12150 1
1250 1760 14670 0.9
1600 2130 17550 0.85
2000 2610 19350 0.75
2500 3150 20700 0.75
3150 38.5
35
3870 24300 0.7 7
4000 4640 28800 0.7
5000 5490 33030 0.6
6300 6570 36900 0.6
8000 ±2×2.5% YNd11 9000 40500 0.55 8
10000 10600 47700 0.55
12500 12600 56700 0.5
16000 15.3 69300 0.5
20000 18090 84000 0.5
25000 21510 99000 0.4 10
31500 25650 119000 0.4

Note :outline dimension is designed according to requirements

 

35KV Oil-immersed Transformer

S-35KV Series Non-excitation Voltage Regulating Transformer

S11-50~1600/35KV technical data

Rated

capacity

(kVA)

Voltage combination Connection symbol No-load loss(W) Load

loss(W)

No-load

current

(%)

Short circuit

impedance

(%)

H.V

(kV)

Tapping range of high voltage L.V

(kV)

50  

 

 

 

 

 

 

35

 

 

 

 

 

 

 

±5

 

 

 

 

 

 

 

0.4

 

 

 

 

 

 

 

Dyn11

Yyn0

170 1210/1150 2.00  

 

 

 

 

 

 

6.5

100 230 2010/1920 1.80
125 270 2380/2260 1.70
160 290 2820/2690 1.60
200 340 3330/3160 1.50
250 410 3950/3760 1.40
315 490 4760/5450 1.40
400 580 5750/5470 1.30
500 690 6920/6580 1.20
630 830 7870 1.10
800 980 9410 1.00
1000 1150 11540 1.00
1250 1410 13940 0.90
1600 7000 16670 0.80

Note:the load loss values above the diagonal line in the table are applicable to the Dyn11 coupling group,and the load loss values below the diagonal line are applicable to theYyn0 coupling group.

 

 

 

S11-630~31500/35KV technical data

Rated

capacity

(kVA)

Voltage combination Connection symbol No-load

loss(W)

Load

loss(W)

No-load

current

(%)

Short circuit

impedance

(%)

H.V

(kV)

Tapping range of high voltage L.V

(kV)

630  

 

35

 

 

 

 

±5

 

 

 

 

 

3.15

3.3

6.5

6.6

10.5

 

 

 

 

Yd11

830 7780 1.10  

 

6.5

800 980 9410 1.00
1000 1150 11540 1.00
1250 1410 13940 0.90
1600 1700 16670 0.90
2000 2180 18380 0.70
2500 2560 19670 0.60
3150  

 

 

35

~38.5

3040 23090 0.56 7.0
4000 3620 27360 0.56
5000 4320 31380 0.48
6300 5250 35060 0.48  

 

8.0

8000  

 

±2×2.5

 

 

Ynd11

7200 38480 0.42
10000 8700 45320 0.42
12500 10080 53870 0.40
16000 12160 65840 0.40
20000 14400 79520 0.40
25000 17020 94050 0.32 10.0
31500 20220 112860 0.32

Note :outline dimension is designed according to requirements

 S11-50~1600/35KV technical data

Rated
capacity
(kVA)
Voltage combination Connection symbol No-load loss(W) Load   loss(W) No-load
current
(%)
Short circuit
impedance
(%)
(kV)H.V Tapping range of high voltage L.V
(kV)
50 35 ±5 0.4 Dyn11
Yyn0
170 1210/1150 2 6.5
100 230 2010/1920 1.8
125 270 2380/2260 1.7
160 290 2820/2690 1.6
200 340 3330/3160 1.5
250 410 3950/3760 1.4
315 490 4760/5450 1.4
400 580 5750/5470 1.3
500 690 6920/6580 1.2
630 830 7870 1.1
800 980 9410 1
1000 1150 11540 1
1250 1410 13940 0.9
1600 7000 16670 0.8

Note:the load loss values above the diagonal line in the table are applicable to the Dyn11 coupling group,and the load loss values below the diagonal line are applicable to theYyn0 coupling group.

 S11-630~31500/35KV technical data

Rated
capacity
(kVA)
Voltage combination Connection symbol No-load loss(W) Load   loss(W) No-load
current
(%)
Short circuit
impedance
(%)
(kV)H.V Tapping range of high voltage L.V
(kV)
630 35 ±5 3.15
3.3
6.5
6.6
10.5
Yd11 830 7780 1.1 6.5
800 980 9410 1
1000 1150 11540 1
1250 1410 13940 0.9
1600 1700 16670 0.9
2000 2180 18380 0.7
2500 2560 19670 0.6
3150 35
~38.5
3040 23090 0.56 7
4000 3620 27360 0.56
5000 4320 31380 0.48
6300 5250 35060 0.48 8
8000 ±2×2.5 Ynd11 7200 38480 0.42
10000 8700 45320 0.42
12500 10080 53870 0.4
16000 12160 65840 0.4
20000 14400 79520 0.4
25000 17020 94050 0.32 10
31500 20220 112860 0.32

Note :outline dimension is designed according to requirements

S13-50~2500/35KV technical data

Rated
capacity
(kVA)
Voltage combination Connection symbol No-load loss(W) Load   loss(W) No-load
current
(%)
Short circuit
impedance
(%)
(kV)H.V Tapping range of high voltage L.V
(kV)
50 35
38.5
±2×2.5
±5
0.4 Dyn11
Yyn0
160 1200/1140 1.3 6.5
100 230 2010/1910 1.1
125 270 2370/2260 1.1
160 280 2820/2680 1
200 310 3320/3160 1
250 400 3950/3760 0.95
315 480 4750/4530 0.95
400 580 5740/5470 0.85
500 680 6910/6580 0.85
630 830 7860 0.65
800 980 9400 0.65
1000 1150 11500 0.65
1250 1400 13900 0.6
1600 1690 16600 0.6
2000 1990 19700 0.55
2500 2360 23200 0.55

Note :outline dimension is designed according to requirements

 

 

 