• products
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

RN1 Indoor Current Limiting Fuse
Picture
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse
  • RN1 Indoor Current Limiting Fuse

RN1 Indoor Current Limiting Fuse

1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln, type D(10-20)ln

Conatct Us

Product Details

● The product is used in overload or short-circuit protection for electric transformer. The current limiting means that the fuse will cut off the circuit before the short-circuit current reaches the peak value.

Features

Current which passes the fuse when being1.3 times of itsspecified electric current. Do not fusing for an hour;Whenthe current through the fuse is 2 times of its specinedelectric current. fusing in an hour;Refer to its fusingfeature curve in chart 1when select the fuse.

Figure 1 RN1/RN3“An-second” characteristic curve

2

Technical data

3 6 10 35
Rated current (A) 20 100 200 300 400 200 75 100 200 300 20 50 75 100 200 7.5 10 20 30 40
Max breaking curent KV effective vakue 40 1.3 1.3 1.3
The mininum breaking current Expresswith specified electric   current multipe nuprovide 1.3 nuprovide 1.3 nuprovide 1.3 nuprovide 1.3
Three-phase maximum cut-off capacity(MVA ) 8 8.9 10.8 15.7 15.7 8.5 9.6 13.6 13.6 17 10 11.5 14.5 21 21 10 20 27 27 27

Structure of fuse link

The fuse pipe is the main part of fuse,it is made by installing the fuse wire in the porcelain pipe,filing the quartzsand in the porcelain pipe and sealing to-ends of pipe.For the fuse pipe with rated current below 7.5Aand 35V ratedvoltage,its fuse wire is rolled on the
special porcelain core,referening to chart 2.a.for the fuse pipe with rated currentabove 7.5A,its fuse wire is hang in the porcelain pipe,referening to the chart.

Overall and mounting dimensions(mm)

Chart 2-the section of style fuse pipe

3

Chart 3-the section of style fuse pipe

4

1. Cover
2. Cap
3. Porce lain pipe
4. Fuse wire
5.Quartz sand
6. lndicator fuse wire
7. Spring
8. lndicator
9. Porcelain core
10. Rubber washer

Technical data

Product type Product code Diagram number Rated voltage Fuse current A Main size
number A a L H1 H b
RN1-6/2 RN3 Figure 3 6 2 310 500 550 125 235 108
RN1-6/3 RN3 3
RN1-6/5 RN3 5
RN1-6/7.5 RN3 7.5
RN1-6/10 RN3 10
RN1-6/15 RN3 15
RN1-6/20 RN3 20
RN1-10/2 RN3 10 2 410 600 650
RN1-10/3 RN3 3
RN1-10/5 RN3 5
RN1-10/.7.5 RN3 7.5
RN1-10/10 RN3 10
RN1-10/15 RN3 15
RN1-10/20 RN3 20
RN1-10/25 RN3 25
RN1-10/30 RN3 30

5

Product type Product code Diagram number Rated voltage Fuse current A Main size
number A a L H b
RN1-3/150 RN3 3 150 270 400 450 350 108
RN1-3/200 RN3 200
RN1-6/100 RN3 Figure 6 6 100 360 500 550
RN1-6/150 RN3 150
RN1-6/200 RN3 200
RN1-10/75 RN3 10 75 460 600 650
RN1-10/100 RN3 100

6

Product type Product code Diagram number Rated voltage Fuse current A Main size
number A a L b
RN1-10/80 RN3 Figure 7 10 80 460 600 650 108
RN1-10/100 RN3 10 100
RN1-10/150 RN3 10 150
RN1-10/200 RN3 10 200
Write your message here and send it to us

Related Products