Solar PV Cable is mainly used to interconnect solar panels and inverters in solar system. We use the XLPE material for insulatlon and jacket so that the cable can resist sun irradiate, it also can be used in high and low temperature environment.
Cable Full Name:
Halogen-free low smoke cross-linked polyolefin insulated and sheathed cables for
photovoltaic power generation systems.
Conductor Structure:
En60228 (IEC60228) Type five conductor and must be tinned copper wire. Cable Color:
Black or Red (The insulation material shall be extruded halogen-free material, which shall be composed of one layer or several tightly adhered layers. The insulation shall be solid and uniform in material, and the insulation itself, the conductor and the tin layershall be as for as possible not damaged when the insulation is peeled off)
Cable Characteristics Double insulated construction, Higher systems bear voltage, UV radiation, Low and High tem-perature resistant environment.
PV15 | 1.5 |
Model | Wire diameter |
Photovoltaic cable PV10: DC1000 PV15: DC1500 |
1.5mm² 2.5mm² 4mm² 6mm² 10mm² 16mm² 25mm² 35mm² |
Rated voltage | AC:Uo/U=1.0/1.0KV,DC:1.5KV |
Voltage test | AC:6.5KV DC:15KV,5min |
Ambient temperature | -40℃~90℃ |
Maximum conductor temperature | +120℃ |
Service life | >25 years(-40℃~+90℃) |
Reference short-circuit allowable temperature | 200℃ 5 (seconds) |
Bending radius | IEC60811-401:2012,135±2/168h |
Compatibility test | IEC60811-401:2012,135±2/168h |
Acid and alkali resistance test | EN60811-2-1 |
Cold bending test | IEC60811-506 |
Damp heat test | IEC60068-2-78 |
Sunlight resistance tTest | IEC62930 |
Cable ozone resistance test | IEC60811-403 |
Flame retardant test | IEC60332-1-2 |
Smoke density | IEC61034-2,EN50268-2 |
Evaluate all non-metallic materials for halogens | IEC62821-1 |
● 2.5m² ● 4m² ● 6m²
Photovoltaic cable structure and recommended current carrying capacity table
Construction | Conductor Construction | Conductor Quter | Cable Outer | Resistance Max. | Current CarringCapacity AT 60C |
mm2 | nxmm | mm | mm | Ω/Km | A |
1X1.5 | 30X0.25 | 1.58 | 4.9 | 13.7 | 30 |
1X2.5 | 48X0.25 | 2.02 | 5.45 | 8.21 | 41 |
1X4.0 | 56X0.3 | 2.35 | 6.10 | 5.09 | 55 |
1X6.0 | 84X0.3 | 3.2 | 7.20 | 3.39 | 70 |
1X10 | 142X0.3 | 4.6 | 9.00 | 1.95 | 98 |
1x16 | 228X0.3 | 5.6 | 10.20 | 1.24 | 132 |
1x25 | 361X0.3 | 6.95 | 12.00 | 0.795 | 176 |
1x35 | 494X0.3 | 8.30 | 13.80 | 0.565 | 218 |
The current-carrying capacity is under the situation of laying the single cable in air.