General
YCB7RL-100 series electromagnetic residual current operated circuit breaker (RCCB) is mainlysuitable for AC distribution networks with a rated working voltage of 230V or 400V at 50Hzand a rated current of 63A.Used for indirect contact protection of people,and can also beused to prevent fire hazards caused by insulation damage to circuits and equipment,resulting in ground fault currents.
General
YCH7-125 series isolating switch is suitable in the resistive circuit of AC 50/60HZ,rated voltage 230/400V,rated current up to 125A.
It’s used primarily for circuit’s turning on or off in non-loadedsituation.And it functions on connection and isolation between lines and power,especially suitable to isolate power effectively and prevent circuit breaker from closing acidentally when maintain the circuit in order to ensure the safe operation of maintainer.
Standard:IEC600947-3
The YCB7-63N series miniature circuit breaker are suitable for overcurrent protection building line facilities and similar purposes in AC 50/60Hz, rated voltage 230V/400V,
Function
1. Personnel and fire protection
2. Cable and line protection against overload and short-circuits.
Selection
1. I∆n ≤ 30 mA: additional protection in the case of direct contact.
2. I∆n ≤300 mA: preventative fire protection in the case of ground fault currents.
3. AC class – Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
1.Overload protection
2.Short circuit protection
3.Controlling
4.Used in residential building,non-residential building,energy source industry and infrastructure.
General
1.Protection against overload and short-circuit currents
2.Protection against the effects ofsinusoidal alternating earthfault currents
3.Protection against indirectcontacts and additional protection against direct contacts.
4.Protection against fire hazard caused by insulation faults
5.Used in residential building
6.According tothe type of instantaneous release classified as follows:type B(3-5)In,type C(5-10)In,type D(10-20)In
YCS7N series Surge Protection Device (SPD) is suitable for TT, IT, TN-S, TN-C and TN-C-S, the power supply system with the rated voltage up to 230/400V and AC 50/60Hz. Its design corresponds to IEC61643-1. The product is usually installed in the incoming line low voltage distribution box of the building, and it can release 80kA lightning stroke current.
General
YCP5 series AC Motor Starter is suitable for circuits the alternating voltage up to690V,current up to 80A.The product works to control theoverload,phase loss,shortcircuit protection and infrequent starts of a three-phase squirel cage asynchronousmotor.The Motor Starter can protect the distributing line for infrequent loadtransfer,and it can also works as an isolator
YCW9X-1600 integrated circuit breaker is one of the new circuit breakers developed using advanced technology. This product is suitable for general distribution systems, new energy distribution systems, multi-energy distribution networks, inverters and distributed power rotation. It has isolation function, small size, high breaking capacity and other multi-functional features for grid-connected operation and protection of motor power supplies.