• products
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

LZZBJ9-10 Current Transformer
Picture
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer
  • LZZBJ9-10 Current Transformer

LZZBJ9-10 Current Transformer

1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln, type D(10-20)ln

Conatct Us

Product Details

● This current transformer is of a whole sealing casting insulation pillar type, used for measurement of current and electric energy as well as relay protection in the AC circuit of rated frequency 50Hz and rated voltage 10kV.
● Standard:IEC 61869-2.

Selection

6.1

Technical data

1. The performance of products is conformed to IEC standard and GB1208-2006 Current Transformer.
2. Rated insulation level: 12/42/75kV
3. Load power factor: cosΦ =0.8(Lag)
4. Rated frequency: 50Hz
5. Rated secondary current: 5A, 1A
6. Partial discharge level: In conformity to GB5583-85 standard, its partial discharge is not more than 20PC.

 Technical data

Model Rated primary current (A) Accurate class combination Rated secondary output(VA) Rated short-time thermal current (KA virtual value) Rated dynamic stability current (KA peak)
0.2,0.2S 0.5, 0.5S 10P10 10P15
LZZBJ9-10 (A,B,C) 5 0.2/10P
0.2S/10P
0.5/10P
0.5S/10P
10 10 10 15 2 5
10 4.5 11
15 6.3 15
20 9.5 23
30 12.6 31.5
40 18 45
50 22 55
70 36 80
100-200 50 90
300-600 72 100
800-1250 80 110
1500-3150 100 130

Model Rated Primary Current (A) Accurate class combination Rated output (VA) Rated short-time thermal current  (KA virtual value) Rated dynamic stability current (KA peak)
LZZBJ9-10A5G 20,30,40,50,75,100 0.2/0.2/5P10
0.2/0.5/5P15
0.2/0.5/5P20
0.2/5P10/10P15
0.5/5P10/10P20
10/10/40
10/15/30
10/15/20
10/20/20
10/20/15
150I1n 375I1n
150,200 31.5 80
300,400 45 112.5
500 63 130
600,800 0.2/0.2/5P10
0.2/0.5/5P15
0.2/0.5/5P20
0.2/5P10/10P15
0.5/5P10/10P20
10/10/40
10/15/30
10/15/20
10/20/20
10/20/15
63 130
1000,1200,1250 0.2/0.2/5P10
0.2/0.5/5P15
0.2/0.5/5P20
0.2/5P10/10P15
0.5/5P10/10P20
10/10/40
10/15/30
10/15/20
10/20/20
10/20/15
80 160
1500 0.2/0.2/5P10
0.2/0.5/5P15
0.2/0.5/5P20
0.2/5P10/10P15
0.5/5P10/10P20
10/10/40
10/15/30
10/15/20
10/20/20
10/20/15
100 160
2000
2500 0.2/0.2/5P10
0.2/0.5/5P15
0.2/0.5/5P20
0.2/5P10/10P15
0.5/5P10/10P20
10/10/40
10/15/30
10/15/20
10/20/20
10/20/15
100 160
3000,3150 0.2/0.2/5P10
0.2/0.5/5P15
0.2/0.5/5P20
0.2/5P10/10P15
0.5/5P10/10P20
10/10/40
10/15/30
10/15/20
10/20/20
10/20/15
100 160

Outline and Installation

Fig 1 Overall and installation dimension of LZZBJ9-10A current transformer

6.2

Fig 2 Overall and installation dimension of LZZBJ9-10B current transformer

6.3

Outline and Installation

Fig 3 Overall and installation dimension of LZZBJ9-10C current transformer

6.4

Fig 4 Overall and installation dimension of LZZBJ9-10C 2 current transformer

6.5

Outline and Installation

Fig 5 Overall and installation dimension of LZZBJ9-10A5G 5-1000A current transformer

6.6

Fig 6 Overall and installation dimension of LZZBJ9-10A5G 1200-3000A current transformer

6.7

Write your message here and send it to us

Related Products