LW28 Series Universal changeover switch mainly used for AC 50/60Hz, rated voltage up to 380V and below, DC voltage up to 220V, rated current to 160A electrical circuit for manually infrequent making or breaking the circuit for the purposes of control and conversion ,can also controlling three-phase asynchronous motors and circuit directly as the purposes of master control and measurement. The products widely used, instead of the various national switch, can be used as the circuit control switch, measuring equipment switches, motor control switches and the master control switch,and welding machine switch and so on.
standard: IEC60947-3
1. The ambient air temperature does not exceed +40℃, the average temperature within 24 hours and not more than +35℃.The ambient air temperature is not lower than -5℃ .
2. Installation site altitude does not exceed 2000m
3. The relative humidity of the air no more than 50% when the maximum
temperature is +40℃ and at a lower temperature allows a higher relative
humidity, such as when temperature is 20℃ the relative humidity reaches 90%.
4. Special measures should betaken for condensation occassionally due to temperature changes.
For use to master control
LW28 | - | 20 | / | 2P | 2 | |
LW28 | Rated thermal current | Poles | Station | |||
Universal changeover switch |
10:10A 20:20A 25:25A 32:32A 63:63A 125:125A 160:160A 200:200A 315:315A 400:400A |
2P 3P 4P 5P 6P |
2 3 4 5 6 7 |
|||
V: Voltage meter A: Ammeter |
Note:If there are special wiring requirements, please provide the wiring diagram or contact us
The following table shows the relevant dimension of the transfer switch
Table 2
Model | Ith A |
Ui V |
Ue V |
AC-21A | AC-22A | AC-23A | AC-2 | AC-3 | AC-4 | AC-15 | DC-13 | ||||
le A |
le A |
le A |
kW | le A |
kW | le A |
D kW |
le A |
kW | le A |
le A |
||||
LW28-10 | 10 | 660 | 240 | 10 | 7.5 | 1.8 | 7.5 | 2.5 | 5.5 | 1.5 | 1.75 | 0.37 | 2.5 | ||
10 | 660 | 440 | 10 | 7.5 | 3.0 | 7.5 | 3.7 | 5.5 | 2.2 | 1.75 | 0.55 | 1.5 | |||
LW28-20 | 20 | 660 | 440 | 20 | 15 | 7.5 | 15 | 7.5 | 11 | 5.5 | 3.5 | 1.5 | 4 | ||
20 | 660 | 240 | 5 | 1 | |||||||||||
20 | 660 | 120 | 5 | ||||||||||||
LW28-25 | 25 | 660 | 440 | 25 | 22 | 11 | 22 | 11 | 15 | 7.5 | 6.5 | 3 | 5 | ||
25 | 660 | 240 | 8 | 1.5 | |||||||||||
25 | 660 | 120 | 9 | ||||||||||||
LW28-32 | 32 | 660 | 440 | 32 | 30 | 15 | 30 | 15 | 22 | 11 | 11 | 5.5 | 6 | ||
32 | 660 | 240 | 14 | 11 | |||||||||||
32 | 660 | 120 | 25 | ||||||||||||
LW28-63 | 63 | 660 | 440 | 63 | 57 | 30 | 57 | 30 | 36 | 18.5 | 15 | 7.5 | |||
63 | 660 | 120 | 55 | ||||||||||||
LW28-125 | 125 | 660 | 440 | 125 | 90 | 45 | 90 | 45 | 75 | 30 | 30 | 12 | 90 | ||
LW28-160 | 160 | 660 | 440 | 160 | 135 | 75 | 135 | 55 | 95 | 37 | 55 | 15 | 110 |
The following table shows the relevant dimension of the transfer switch
Table 3
Model | Panel Specification |
Dimensions(mm) | Model | Panel Specification |
Dimensions(mm) | ||||||
A | B | C | L | A | B | C | L | ||||
LW28-10 | M0 Square | 30 | 30 | 28 | 22+8n | M2 Square | 64 | 64 | 58 | 29.2+12.8n | |
M1 Square | 48 | 48 | 43 | 22+9.6n | LW28-32 | M2 Rectangle | 64 | 80 | 58 | 29.2+12.8n | |
LW28-20 | M2 Square | 64 | 64 | 43 | 25+9.6n | M3 Square | 88 | 88 | 58 | 29.2+12.8n | |
M2 Rectangle | 64 | 80 | 43 | 25+9.6n | M2 Square | 64 | 64 | 66 | 29.2+21.5n | ||
M2 Square | 64 | 64 | 60 | 42.5+12.6n | LW28-63 | M2 Square | 64 | 80 | 66 | 29.2+21.5n | |
LW28-20c | M2 Rectangle | 64 | 80 | 60 | 42.5+12.6n | M3 Square | 88 | 88 | 66 | 29.2+21.5n | |
M3 Square | 88 | 88 | 60 | 42.5+12.6n | LW28-125 | M3 Square | 88 | 88 | 84 | 35+26.5n | |
M1 Square | 48 | 48 | 45.2 | 23+12.8n | LW28-160 | M3 Square | 88 | 88 | 88 | 35+32.5n | |
LW28-25 | M1 Rectangle | 48 | 60 | 45.2 | 23+12.8n | LW28-315 | M4 Square | 130 | 130 | 126 | 39.5+38.5n |
M2 Square | 64 | 64 | 45.2 | 26.5+12.8n | |||||||
M2 Rectangle | 64 | 80 | 45.2 | 26.5+12.8n |