Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Product Overview

  • Product Details

  • Data download

  • Related Products

Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
Pictura
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8
  • Photovoltaic DC Surge Protective fabrica YCS8 S YCS8

Photovoltaic DC Surge tutela fabrica YCS8-S ...

Generativus
YCS8 Series photovoltaic DC Surge defensiva fabrica est applicabilis ad photovoltaic potentia generationem ratio. When surge overvoltage occurs in the system due to lightning stroke or other reasons, the protector immediately conducts in nanosecond time to introduce the surge overvoltage to the earth, thus protecting the electrical equipment on the grid.

Contact Us

Product Details

Responsulli 3D Model
I

Generativus

YCS8- □ series applicabiles ad photovoltaic potentia generationem ratio. When surge overvoltage occurs in the system due to lightning stroke or other reasons, the protector immediately conducts in nanosecond time to introduce the surge overvoltage to the earth, thus protecting the electrical equipment on the grid.

Features

● T2 / T1 + T2 Software praesidio habet duo genera tutela, quae potest videre genus I (10/350 μs waveform) et genus II (8/20 μs waveform) Spd 1.5kv, et voltage praesidio gradu usque ≤ 1.5kv;
● modularis, magna-capacitatem spd, maximum missionem current imax = 40ka;
● pluggable module;
● secundum cadmiae technology cadmiae, non habet potestatem frequency aftercurrent et ieiunium responsio celeritas, usque ad 25ns;
● in viridi fenestra indicat normalis, et rubrum indicat ad defectum, et moduli necessitates reponi;
● Dual scelerisque Disiunctio fabrica providet magis certa tutela;
● remotis signum contactus sunt ad libitum;
● eius incerta tutela range potest esse a potentia ratio ad terminales apparatu;
● est applicabilis directe fulgur praesidium et surge praesidio DC Systems ut PV PV PV et PV distribution arca archa.

Lectio

 

YCS8 - S I + II 40 PV 2P DC600 /
Exemplar Genimen Test Category Maximus
ecfundo
Current
Usurpo
genus
Numerus
vectes
Maximus
continuus
operatus
voltage
Munera
SPD /; Latin genus
S: Upgraded Type
I + II: T1 + T2 XL, 40ka PV:
Photovoltaic /
DESTIGATUS
II, 2p DC600 /: Non
communicatio
R: remotis
communicatio
III, 3p DC1000
Dc1500
II: T2 II, 2p DC600
III, 3p DC1000
Dc1500

Technical notitia

Exemplar YCS8
Vexillum Iec61643-31, MMXVIII; En 50539-11, MMXIII + A1: MMXIV
Test Category T1 + T2 T2
Numerus polos 2P 3P 2P 3P
Maximum continua operantes voltage UCPV 600vdc 1000vdc 600vdc 1000vdc
Maximus missionem current imax (ka) 40
Nominal missionem current in (ka) 20
Maximum impetus current claudicat (ka) 6,25 /
Voltage Protection Level Sursum (KV) 2.2 3,6 2.2 3,6
RESPONSIO Tw (NS) ≤25
Remotis indicium
Opus status / culpa indication Green / Rubrum
Remote contactus Libitum
Remotis terminatio
Switching capability
AC 250v / 0.5a
DC 250VDC / 0,1a / 125VDC 0.2A / 75VDC / 0.5a
Longinquus Terminal Connection Capability 1.5mm²
Installation et environment
Operantes temperatus range -40 ℃ - + LXX ℃
Liceat operantes humiditas V% ... XCV%
Aeris pressura / altitudo 80k PA ... 106K PA / -500M 2000M
Terminatio torque 4.5nm
Conductor crucis sectionem (maximum) 35MM²
Modus installation Din35 vexillum din-rail
Praesidium gradus Ip20
Crusta materia Ul XCIV V-probationem ignis-probationem
Scelerisque praesidium Sic

Note: 2P potest nativus alia voltage

Technical notitia

Exemplar Ycs8-s
Vexillum Iec61643-31, MMXVIII; En 50539-11, MMXIII + A1: MMXIV
Test Category T1 + T2 T2
Numerus polos 2P 3P 3P 2P 3P 3P
Maximum continua operantes voltage UCPV 600vdc 1000vdc 1500VDC 600vdc 1000vdc 1500VDC
Maximus missionem current imax (ka) 40
Nominal missionem current in (ka) 20
Maximum impetus current claudicat (ka) 6,25 /
Voltage Protection Level Sursum (KV) 2.2 3,6 5,6 2.2 3,6 5,6
RESPONSIO Tw (NS) ≤25
Remotis indicium
Opus status / culpa indication Green / Rubrum
Remote contactus Libitum
Remotis terminatio
Switching capability
AC 250v / 0.5a
DC 250VDC / 0,1a / 125VDC 0.2A / 75VDC / 0.5a
Longinquus Terminal Connection Capability 1.5mm²
Installation et environment
Operantes temperatus range -40 ℃ - + LXX ℃
Liceat operantes humiditas V% ... XCV%
Aeris pressura / altitudo 80k PA ... 106K PA / -500M 2000M
Terminatio torque 4.5nm
Conductor crucis sectionem (maximum) 35MM²
Modus installation Din35 vexillum din-rail
Praesidium gradus Ip20
Crusta materia Ul XCIV V-probationem ignis-probationem
Scelerisque praesidium Sic

Note: 2P potest nativus alia voltage

Defectum release fabrica, terrorem release fabrica

Defectum release fabrica
Et surge tutela fabrica instructa cum defectum praesidio fabrica. Cum protector est destruxit ex overheating, defectum tutela fabrica potest statim disconnect ex virtute euismod et indicium signum.
Fenestram repraesentationes viridi cum praesidio normalis et rubra cum protector defecerit.

Turbato remota signaling fabrica
Protector fieri potest in varietate remotis signalling contactus. Et remotis signaling contactus habent a paro of Northmanni aperire et Northmanni clausa contactus. Cum praesidio operatur Northmanni, Northmanni clausa contactus connectuntur. Si vel modules protectori deficient, in contactum erit mutare ex Northmanni aperire ad Northmanni clausit et Northmanni aperire contactum et operari et mitte in culpa nuntium.

IV

Wiring Diagram

I

Altiore et ascendens dimensiones (mm)

YCS8

II

Ycs8-s

III

CS8-S DC1500

8_ 看图王
Scribere nuntium hic mitte nobis

Related Products

  • Cino
  • Cino2025-03-14 05:36:09
    Hello, I am ‌‌Cino, welcome to CNC Electric. How can i help you?

Ctrl+Enter Wrap,Enter Send

  • FAQ
Please leave your contact information and chat
Hello, I am ‌‌Cino, welcome to CNC Electric. How can i help you?
Chat Now
Chat Now