Product Overview
Product Details
Data download
Related Products
Contact Us
I. Altitude: Non plus quam 1000m;
II. In environment temperatus: superius terminum + XL ℃, inferior terminus -30 ℃;
III. Relativum Umor: Daily Mediocris valorem non est maior quam XCV%, menstrua mediocris est maior quam XC%;
IV. Saturatum vapor pressura: Daily mediocris valorem non altior quam 2.2 × X -3 MPA, menstrua mediocris non altior quam 1.8 × X -3 MPA;
V. Non gravibus vibratio, nec moriens Gas, non ignem, non CREPITUS periculum est.
Item | Unitas | Parameter |
Technical modularis combinationes | ||
Rated voltage | kV | 12 |
Rated frequency | Hz | 50 |
Maxime rated current de Fuse | A | CXXV |
Translationem current | A | MDL |
In Fuse Tiggered Switch segmentis tempore | ms | XL ± V |
Rated Short-circuitu solveret current | kA | 31.5 |
Rated Short-circuitu claudendo Current (prospiciens Pecco Value) | kA | 80 |
1min virtus frequency resistent intentione (vacuum fractura, interphase, tempus in terra / SECTUM fractura) | kV | 42/49 |
Et fulgur impetus resistere voltage (vacuum fractura, interphase, tempus ad terram / segregatione fractura) | kV | 75/85 |
Fuse Impinging Type | Medium-Sized | |
Technical parametri vacuo onus switch combined electrica appliance | ||
Rated voltage | kV | 12 |
Rated frequency | Hz | 50 |
Current Rated | A | DCXXX |
Rated activae onus fractionis current | A | DCXXX |
Rated Close loop Fractio Current | A | DCXXX |
V% at rated onus fractionis current | A | 31.5 |
Rated cable præcipiens solveret current | A | 10 |
Interruptione non onus transformer facultatem | kva | MCCL |
1min virtus frequency resistent intentione (vacuum fractura, interphase, tempus in terra / SECTUM fractura) | kV | 42/48 |
Et fulgur impetus resistere voltage (vacuum fractura, interphase, tempus ad terram / segregatione fractura) | kV | 75/85 |
4s rated breve tempus resistere current | kA | 31.5 |
Rated Peak resistite current | kA | 80 |
Rated Short-Circuit claudendo current | kA | 80 |
Mechanica vitae | Temporum | (X) |
Liceat cumulative crassitiem gerunt in contactu | mm | 2 |
Foramen et claudendo operating torque | N · M | ≤200 |
I. scrket bracket | VII. Static contactus | XIII. Insulated tensio polus |
II. Disconnector | VIII. Insulator | XIV. Main axe |
III. Fuse | IX. Grounding cultro | XV. Layshft |
IV. Insulated tensio polus | X. Grounding Cultro Spring | XVI. Adjusting iugum |
V. bracket superioris | XI. Aperire vere | XVII. Vere operating mechanism |
VI. Vacuum interrupter | XII. Et aulapens driving fabrica | - |