Contactor AC CJX2S
  • Ringkesan Produk

  • Rincian Produk

  • DATA DOWNLOAD

  • Produk sing gegandhengan

Contactor AC CJX2S
Gambar
Video
  • Contactor AC CJX2S
  • Contactor AC CJX2S
  • Contactor AC CJX2S
  • Contactor AC CJX2S
  • Contactor AC CJX2S
  • Contactor AC CJX2S
  • Contactor AC CJX2S
  • Contactor AC CJX2S
  • Contactor AC CJX2S
  • Contactor AC CJX2S
CJX2S AC Contactor nampilake gambar

Contactor AC CJX2S

Ringkesan Produk
Konstactor AC Series CJX2S kanthi tampilan novel lan struktur kompak cocog karo wiwitan & ngontrol ac motor asring, ngaktifake lan mateni thecircuitat jarak adoh kanggo nyusun wiwitan amagnet
Standariec60947-1, IEC 60947-4-1.

Hubungi kita

Rincian Produk

cjx2s-produk-panjel1
cjx2s-produk-gambaran2
cjx2s-produk-deskripsi3
cjx2s-produk-panjelasan4

Ringkesan Produk

Contactor AC Series CJX2S kanthi tampilan novel lan struktur kompak cocog kanggo nggunakake wiwitan & ngontrol ac motor asring, ngalih lan mateni sirkuit kanthi jarak sing dawa. Iki digunakake ing kombinasi karo relay termal kanggo nyusun wiwitan motor magnet.
Standar: IEC 60947-1, IEC 60947-4-1.

Spesifikasi

Saiki operasi saiki (yaiku): 9-95a;
Voltase Operasi sing dirating (UE): 220V ~ 690V;
Rated insulasi voltase: 690v; cagak: 3P;
Instalasi: Instalasi Din lan Incli.

Kahanan operasi lan instalasi

Ketik Kahanan operasi lan instalasi
Kategori Instalasi III
Tingkat Polusi 3
Gelar Perlindhungan CJX2S-09 ~ 38: IP20; CJX2S-40 ~ 95: IP10
Suhu sekitar Watesan suhu: -35 ℃ ~ + 70 ℃, suhu normal: -5 ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃℃, rata-rata ora luwih saka + 35 ℃ ing 24 jam.
Altitude ≤2000m
Suhu sekitar Suhu maksimal 70 derajat, kelembapan relatif udhara ora ngluwihi 50%, lan suhu ing ngisor 50% bisa ngidini kelembapan relatif sing luwih dhuwur. Yen suhu 20 ℃, udhara relatif asor bisa nganti 90%, langkah-langkah khusus kudu dibanting kanggo kondensasi kadang amarga owah-owahan asor.
Posisi instalasi Interlinasi antarane permukaan instalasi lan lumahing vertikal ora kudu ngluwihi ° 5 °
Kederuhan Kaget Produk kudu diinstal lan digunakake tanpa goyangake, kejut lan geter.

Sakabèhé lan dipasang

CJX2S-09 ~ 38

cjx2s-produk-deskripsi7

CJX2S-40 ~ 95

cjx2s-produk-panjelasan8
F4-D, blok kontak LA3-D
Lx1-d coil
Asile produk nalika kontactor dipasang karo modul aksesoris ing ngisor iki
F4-D, blok kontak LA3-D

Foto CX2S 110 AC

Lx1-d coil

Asile produk nalika kontactor dipasang karo modul aksesoris ing ngisor iki

Spesifikasi

Ketik CX2S09 CX2S12 CX2S-18 CX2S25 CX2S32 CX2S38 CX2S40 CX2S50 CX2S65 CX2S80 CX2S95 CX2S-110
Circeristik sirkuit utama  CX2S-09-AC-Contactor-MCB  CX2S 18-25 AC contactor mcB  CX2S 32-38 AC contactor mcb  Contactor cx2 40-65 AC  Contactor A 80-1 80-110 AC
Cagak 3P
Rated insulasi voltase (UI) V 690
Voltase operasi sing dirating (ue) V 380 / 400,660 / 690
TENAGA KANGGO GRATIS (ITH), AC-1 20 20 32 40 50 50 50 60 80 125 125 140
Operasi dirating
Saiki (le)
AC-3,380 / 400V A 9 12 18 25 32 38 40 50 65 80 95 110
AC-3,660 / 690V A 6.6 8.9 12 18 22 22 34 39 42 49 49 49
AC-4,380 / 400V A 3,5 5 7.7 8.5 12 14 18.5 24 28 37 44 44
AC-4,660 / 690V A 1.5 2 3.8 4.4 7,5 8.9 9 12 14 17.3 21.3 21.3
Dirating
operasional
Daya (PE)
AC-3,380 / 400V kW 4 5.5 7,5 11 15 18.5 18.5 22 30 37 45 45
AC-3,660 / 690V KW 5.5 7,5 10 15 18.5 18.5 30 33 37 45 45 45
AC-4,380 / 400V KW 1.5 2.2 3.3 4 5.4 5.5 7,5 11 15 18.5 22 22
AC-4,660 / 690V KW 1.1 1.5 3 3.7 5.5 6 7,5 10 11 15 18.5 18.5
Urip mekanik 10000
kaping
1200 1000 900 650
Urip listrik Ac-3 110 90 65
AC-4 22 22 17 11
Frekuensi saka
Operasi
Ac-3 kaping /
jam
1200 600
AC-4 300 300
Kapabilitas Nyambungake saka Teminal Sirkuit Utama
Kawat Fleksibel 1 kawat mm² 1..4 1.5..6 2,5 ... 25 4 ... 50
Ora terminal 2 kawat mm² 1 ... 4 1.5..6 2.5 ... 16 4 ... 25
Kawat Fleksibel 1 kawat mm² 1 ... 4 1..6 2,5 ... 25 4 ... 50
Kanthi teminal 2 kawat mm² 1 ... 2,5 1 ... 4 2.5 ... 10 4 ... 16
Kabel Hard 1 kawat mm² 1 ... 4 1.5..6 1.5 ... 10 2,5 ... 25 4 ... 50
Ora terminal 2 kawat mm² 1 ... 4 1.5 ... 2.5 ... 10 4 ... 25
Torsi Fastening N · m 1.2 1.8 5 9
Coil
Kontrol dirating
Voltase (AS)
50hz V 24,36,48,110,2,27,27,27,27,27,27,27,240,380 / 400,415,440
50 / 60hz V 24,36,48,110,2,27,27,27,27,27,27,27,240,380 / 400,415,440
Kontrol sing diidini
sirkuit
Voltase (AS)
Operasi V Angole Instalasi Instalasi ± 22.5 °: 85% ~ 110% AS; sudut karep instalasi ± 5 °: 70% ~ 120%
Rilis V Angole Instalasi Instalasi ± 22.5 °: 20% ~ 75% AS; Angle Instalasi Instalasi ± 5 °: 20% ~ 65%
Kekuwatan
Onsumsi
OFCAIL
Actuation VA 60 70 200 200
Terus VA 6-9.5 6-9.5 15-20 15-20
Konsumsi W 1-3 1-3 6-10 6-10
Kontak bantu
Spesifikasi Kontak Bantu A 11
Curent Themal (LTH) A 10
Ngolah Operasi
voltase (ue)
AC V 380
DC V 220
Kontrol dirating
kapasitas
AC-15 VA 360
DC-13 W 33
Sertifikasi CE, TUV, CB
Ketik Amax Bmax Cmax a b c d e f
CJX2S-09, 12, 18 taun 74.5 45.5 85.5 35 50/60 - - - -
CJX2S-25, 32, 38 83 56.5 97 40 50/70 - - - -
CJX2S-40, 50, 65 127.5 74.5 117 - - 105 40 100/110 59
CJX2S-80, 95 127.5 85.5 125.5 - - 105 40 100/110 67
Tulis pesen sampeyan ing kene lan dikirim menyang kita

Produk sing gegandhengan