HY2.5WD Surge Arrester
  • Yfirlit yfir vöru

  • Upplýsingar um vörur

  • Niðurhal gagna

  • Tengdar vörur

HY2.5WD Surge Arrester
Mynd
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester
  • HY2.5WD Surge Arrester

HY2.5WD Surge Arrester

Starfsemi
1. Hitastig umhverfisins er ekki hærra en +40 ℃ engin neðri-40 ℃;
2. Hæð yfir sjávarborðsskammti fer ekki yfir 1000-2000m (hásléttan ætti að vera tilgreind þegar pantað er);
3.AC Systen Tíðni er 50Hz eða 60Hz
4. Þakið tíðni spennu sem er notuð í arrester í langan tíma fer ekki yfir stöðugar vinnuspennu af arrester
5.Maximum vindhraði fer ekki yfir 35m/s
6. Jarðskjálftastyrkur fer ekki yfir 7 gráður;
7. Skítug svæði ættu að vera vísbending.

Hafðu samband

Upplýsingar um vörur

Rekstrarskilyrði

1.

2.

3. AC systen tíðni er 50Hz eða 60Hz;

4.. Rafmagnsspenna, sem beitt er á Arrester í langan tíma, fer ekki yfir stöðuga vinnuspennu arrester;

5. Hámarks vindhraði fer ekki yfir 35m/s;

6. Jarðskjálftastyrkur fer ekki yfir 7 gráður;

7. Skítugt svæðið ætti að fá skýra vísbendingu.

Eiginleikar

Sinkoxíðskiptum er beitt til að vernda rafmagnsjöfnuna í AC raforkukerfi gegn tjóni vegna andrúmslofts yfirspennu og yfirspennu í rekstri.

Tæknileg frammistaða

Tæknileg afkoma vörunnar staðfestir við GB11032-2000, IEC60099-4, IEEE.C62.11 Venjulegar tæknilegar kröfur.

Hyws1 Serise Arrester

1

Tæknileg gögn

Tegund Kerfið metið
Spenna
KV (RMS)
Arrester metinn
Spenna
KV (RMS)
Stöðugt
Metin spenna
KV (RMS)
DC1MA
Spenna
(KV)
Eldingar
Hvati leifar
Spenna
(KV)
Bratt bylgja
Hvati leifar
Spenna
(KV)
2ms ferningur
Bylgjuhögg
Núverandi
standast
(A)
HYWS -3,8/17 3 3.8 2.4 7.5 17 19.6 100
HYWS -7,6/30 6 7.6 4 15 30 34.5 100
HYWS -12,7/50 10 12.7 6.6 26 50 57.5 150
HYWS17/50 10 17 13.6 26.5 50 57.5 150
Hywz-7.6/27 6 7.6 4 14.5 27 31 200
Hywz-12.7/45 10 12.7 6.6 24 45 51.8 200
Hywz-17/45 10 17 12.7 24 45 51.8 200
Hywz-42/134 35 52 40.8 78 134 154 400
HY2.5WD-7.6/19 605 7.6 4.8 11.5 19 21.9 200, 400
HY2.5WD-12.7/31 10.5 12.7 6.6 19 31 35.7 200, 400
HY2.5WD-16.7/40 13.8 16.7 9 25 40 46 400
HY2.5WD-19/45 15.7 19 10 28.5 45 51.8 400
HY5WR-7.6/27 6 7.6 4.8 13.8 27 20.8 400
HY5WR-12.7/45 10 12.7 6.6 23 45 35 400
HY5WR-42/134 35 52 23.4 73 134 105 400

Umsókn

Taktu HY5WS-17/50 Sem dæmi: H-samskipta kápu í lífveru; y-metal oxíð eldingar; 5--Markið kallar á að kveikja

Rafmagn rafstraumurinn (KV); w-thew meðaltal til að hafa enga clefthe c þýðir að koma á klofanum; S-the s þýðir að fara saman

með rafmagninu; Z Rafmagn stendur; D rafmagnsverkfræði gerð; R Rafmagnsgeta gerð 17-forðast þrumu summan setur rafmagnsspennuna (KV) 50-

Merkið kallar á að kveikja á raforku raforkustraumi Botn Bottest Press (KV).

Skrifaðu skilaboðin þín hér og sendu þau til okkar

Tengdar vörur