FKN(R)12A-12 Load Switch
Picture
  • FKN(R)12A-12  Load Switch
  • FKN(R)12A-12  Load Switch

FKN(R)12A-12 Load Switch

1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln, type D(10-20)ln

Conatct Us

Product Details

FKN(R)12A-12 Indoor Vacuum Load Switch

KN12A- 12D pneumatic load switch and FKRN12A- 12D series air compressor load switch fuse are combination apparatus; Suitable for the control and protection of power equipment such as transformers and overheadlines in three-phase distribution systems with a rated voltage of 12kV and below; Especially suitable for terminal substations and box substations in urban and rural power grids, suitable for control and protection of ring networks and dual radiation power supply unitsThe FKN12A- 12D series pneumatic load switch can be used for breaking and making load current and overload current.
FKRNI2A- 12D series air compressor load switch fuse combination apparatus can break and close load current,overload current and short-circuit current of the line.
Standard: IEC 60265-1,IEC 265,IEC 420.

Selection

 

Operating conditions

1. Ambient air temperature: upper limit + 40℃ , The lower limit is – 25℃ ;
2. The altitude is not more than 1000m;
3. Relative air temperature: the target average value s hall not be greater than 95%.and the monthly average value s hall not be greater than 90%,
4. The seismic intensity should not exceed 8 degrees;e.
5.No fire, explosion, chemical corrosion and severe vibration places;
6. Pollution level: II

Technical data

Name Company FKN12A-12D FKRN12A-12D
Rated voltage KV 12 12
Rated frequency Hz 50 50
Rated current A 630 125
Rated insulation:level 1min power frequency withstand voltage To ground,alternatc KV 42 42
lsolation fracture 48 48
Lightning impulse withstand voltage(peak value) To ground,.alternate 75 75
Isolation fracture 85 85
Rated short time withstand current Load switch KA 20 /
(thermally stable current) Earthing switch 20 /
Rated shortcircuit duration(thermal stability time) Load switch A 4 /
Earthing switch 2 /
Rated short circuit making current(peak value) KA 50 /
Rated breaking current Rated active load Breaking current A 630 /
Closed loop breaking current 630 /
5% active load Breaking current 31.5 /
Cable charging breaking current 10 /
Switching off no-load transformer Compressor capacity KVA 1250 /
Rated short circuit breaking current(current limiting fuse) KA / 31.5
Rated transfer current A / 1200
Impactor output energy Swcond 2000 2000
Mechanical life J / 1±0.5

 

Name Company Data
Fracture opening distance mm ≥175
Center distance between phases 210±2
Air gap between phases ≥125
Trip 210±4
Overtravel 41士3
Three phase closing in different periods ms ≤10
Three phase opening in different periods ≤5
Inherent opening time of shunt release 40~ 65
Main circuit resistance μΩ ≤130

 

Transformer capacity (kVA) 100 125 160 200 250 300/315 400 500 630 750/800 1000 1250
Rated current of fuse(A) 16 16 16 20 25 31.5 40 50 63 80 80 100
100 125

structure

The typical structure of this series of products is shown in Figure 6

0

Overall and mounting dimensions(mm)

New FKN12 installation size formal installation(Inverted Right)

0
New FKN12 installation size formal installation(Inverted Left)

0
New FKN12 Installation Size Inversion(Inverted Right)

1
New FKN12 Installation Size Inversion(Inverted Left)

2

 

 

 

 