JDZ3-3,6,10(Q)type single-phasedouble coil voltage transformer of epoxy casting insulationfor indoor device use,is used formeasurement of voltage and electric energy,relay protection in the AC circuit of rated frequency 50Hz as wellas other controldevicepower.(refer to figure 1 wiring diagram)
JDZ0)-3,6,10(Q)type single-phase double coil voltage transformer of epoxy casting insulation for indoor device use is used formeasurement of voltage and electric energy,relay protection in neutral non-direct earthing system of rated frequency 50Hz aswell asfor other control device power(refer to figure2 wiringdiagram)
Standard.IEC61869-3
Technical data
1.Standard:GB1207-2006 voltage transformer
2.Technical parameterform
3.The creepage of product surface complywith Grade ll ofpollution.
4.Other technical parameter pleaserefers to tablebelow
YSM6-12/24 unit type SF6 RMU with SF6 load switch as main switch,for whole cabinet issuitable forelectric distributionautomation and compact alsoexpandable metal close switchgeart Itcharacters in its simplestructure,flexible operation,reliableinterlocking andconvenient installation etc,which can provide the satisfactory technical projects both for different applicationoccasions and users.Withthe adoption of sensor technology and the protection relay up to date,plus the advanced technologyand flexible assemblyproject.
KYN28A-12 indoor metal clad movable switchgear is a complete power distribution device for 3.6kV~12KV,3 phase AC 50/60Hz,single bus sectionalized system.It is mainly used for power transmissionof middle/smallgenerators in power plants,powerreceiving,transmission for substations in power distribution and power system of factories,mines and enterprises etc.so as tocontrol,protectand monitor the system.
Standard.IEC62271-200
Operating conditions
1.Suitable for environments with an upper limitof 40℃and a lowerlimit of -30℃
2.Altitude notexceeding 1000m,wind speed not exceeding 35m/s
3.Fusesarenot suitable forthefollowing locations
3.1 Places with fuel or explosion hazards.
3.2 Places with severe vibration or impact.
3.3 Areas with abnormal electrochemical gas effects and severe airpollution and smoke
Operatingconditions
1.The ambientair temperatures isno higher than +40℃no lowerthan-40℃;
2.The altitude above sea level dose not exceed 1000-2000m(the plateau ares should be indicated when ordering);
3.AC systen frequency is 50Hz or 60Hz
4.Thepower frequengy voltage aplied to the arrester for a longtime does not exceed the continuous workingvoltageofthe arrester
5.Maximum wind speed does not exceed 35m/s
6.The earthquake intensity does not exceed 7 degrees;
7.The filthy areashould be givendear indication.
The zine oxide arrester is the mostadvanced over-voltage protector in the world,Due to make the risistordisc of core componetmainy adopt zine oxide arrester.Compared with the conventional silicon carbide arresterthis presciption of theproduct improvesgr-eatly the volt-Ampere characterisics of the resistor disc andincreased through-currentcapability at over-voltage so as to dring arad-icalchangesforthe characteristics of the arresters.