Product Overview
Product Details
Data Download
Related Products
In order to satisfy the demands of various pumping applications, YCB2000PV solar pump controller adopts Max Power Point Tracking and proven motor drive technology to maximize output from solar modules. It supports both single phase or three-phase AC input such as a generator or inverter from battery. The controller provides fault detection, motor soft start, and speed control. YCB2000PV controller is designed to proceed these features with the plug and play, ease of installation.
Contact Us
YCB2000PV | T | 5D5 | G | |
Model | Output voltage | Adaptive power | Load type | |
Photovoltaic Inverter |
S:Single phase AC220V T:Three phase AC380V |
0D75:0.75KW 1D5:1.5KW 2D2:2.2KW 4D0:4.0KW 5D5:5.5KW 7D5:7.5KW 011:11KW 015:15KW … 110:110KW |
G:Constant torque |
Model | YCB2000PV-SOD7G | YCB2000PV-S1D5G | YCB2000PV-S2D2G | YCB2000PV-T2D2G | YCB2000PV-T4DOG |
lnput data | |||||
PV Source | |||||
Max input voltage(Voc)[V] | 400 | 750 | |||
Min input voltage,at mpp[V] | 180 | 350 | |||
Recommended voltage,at mpp | 280VDC~360VDC | 500VDC~600VDC | |||
Recommended amps input,at mpp[A] | 4.7 | 7.3 | 10.4 | 6.2 | 11.3 |
Recommended maxpower at mpp[kW] | 1.5 | 3 | 4.4 | 11 | 15 |
Alternate AC generator | |||||
Input voltage | 220/230/240V AV(±15%),Single Phase | 380VAV(±15%),Three Phase | |||
Max amps(RMS)[A] | 8.2 | 14.0 | 23 | 5.8 | 10.0 |
Power and va capability [kVA] | 2.0 | 3.1 | 5.1 | 5.0 | 6.6 |
Output data | |||||
Rated output power[kW] | 0.75 | 1.5 | 2.2 | 2.2 | 4 |
Rated output voltage | 220/230/240VAC,Single Phase | 380V AC,Three Phase | |||
Max amps(RMS)[A] | 4.5 | 7.0 | 10 | 5.0 | 9.0 |
Output frequency | 0-50Hz/60Hz | ||||
Pump system configuration parameters | |||||
Recommended solar panel power(KW) | 1.0-1.2 | 2.0-2.4 | 3.0-3.5 | 3.0-3.5 | 5.2-6.4 |
Solar panel connection | 250W×5P×30V | 250W×10P×30V | 250W×14P×30V | 250W×20P×30V | 250W×22P×30V |
Applicable pump (kW) | 0.37-0.55 | 0.75-1.1 | 1.5 | 1.5 | 2.2-3 |
Pump motor voltage(V) | 3 phase 220 | 3 phase 220 | 3 phase 220 | 3 phase 380 | 3 phase 380 |
Model YCB2000PV-T5D5G YCB2000PV-T7D5G YCB2000PV-T011G YCB2000PV-T015G YCB2000PV-T018G | |||||
Input data | |||||
PV source | |||||
Max input voltage(Voc)[V] | 750 | ||||
Min input voltage,at mpp[V] | 350 | ||||
Recommended voltage,at mpp | 500VDC~600VDC | ||||
Recommended amps input,at mpp[A] | 16.2 | 21.2 | 31.2 | 39.6 | 46.8 |
Recommended max power at mpp[kW] | 22 | 30 | 22 | 30 | 37 |
Alternate AC generator | |||||
Input voltage | 380VAV(±15%),Three Phase | ||||
Max amps(RMS)[A] | 15 | 20 | 26.0 | 35.0 | 46.0 |
Powerand va capability [kVA] | 9.0 | 13.0 | 17.0 | 23.0 | 25 |
Output data | |||||
Rated output power[kW] | 5.5 | 7.5 | 11 | 15 | 18.5 |
Rated output voltage | 380VAC,Three Phase | ||||
Max amps(RMS)[A] | 13 | 17 | 25.0 | 32.0 | 37 |
Output frequency | 0-50Hz/60Hz | ||||
Pump system configuration parameters | |||||
Recommended solar panel power(KW) | 7.2-8.8 | 9.8-12 | 14.3-17.6 | 19.5-24 | 24-29.6 |
Solar panelconnection | 250W×40P×30V 20 series 2 parallel |
250W×48P×30V 24 series 2 parallel |
250W×60P×30V 20 series 3 parallel |
250W×84P×30V 21 series 4 parallel |
250W×100P×30V 20 series 5 parallel |
Applicable pump (kW) | 3.7-4 | 4.5-5.5 | 7.5-9.2 | 11-13 | 15 |
Pump motor voltage(V) | 3 phase 380 | 3 phase 380 | 3 phase 380 | 3 phase 380 | 3 phase 380 |
Model | YCB2000PV-T022G | YCB2000PV-T030G | YCB2000PV-T037G | YCB2000PV-T045G |
Input data | ||||
PV source | ||||
Max input voltage(Voc)[V] | 750 | |||
Min input voltage,at mpp[V] | 350 | |||
Recommended voltage,at mpp | 500VDC~600VDC | |||
Recommended amps input,at mpp[A] | 56.0 | 74.0 | 94.0 | 113 |
Recommended max power at mpp[kW] | 44 | 60 | 74 | 90 |
Alternate AC generator | ||||
Input voltage | 380V AV(±15%),Three Phase | |||
Max amps(RMS)[A] | 62.0 | 76.0 | 76.0 | 90.0 |
Power and va capability [kVA] | 30.0 | 41.0 | 50.0 | 59.2 |
Output data | ||||
Rated output power[kW] | 22 | 30 | 37 | 45 |
Rated output voltage | 380VAC,Three Phase | |||
Max amps(RMS)[A] | 45 | 60 | 75 | 90 |
Output frequency | 0-50Hz/60Hz | |||
Pump system configuration parameters | ||||
Recommended solar panel power(KW) | 28.6-35.2 | 39-48 | 48.1-59.2 | 58.5-72 |
Solar panel connection | 250W×120P×30V 20 series 6 parallel |
250W×200P×30V 20 series 10 parallel |
250W×240P×30V 22 series 12 parallel |
250W×84P×30V 21 series 4 parallel |
Applicable pump(kW) | 18.5 | 22-26 | 30 | 37-40 |
Pump motor voltage(V) | 3 phase 380 | 3 phase 380 | 3 phase 380 | 3 phase 380 |
Model | YCB2000PV-T055G | YCB2000PV-T075G | YCB2000PV-T090G | YCB2000PV-T110G |
Input data | ||||
PV source | ||||
Max input voltage(Voc)[V] | 750 | |||
Min input voltage,at mpp[V] | 350 | |||
Recommended voltage,at mpp | 500VDC~600VDC | |||
Recommended amps input,at mpp[A] | 105 | 140 | 160 | 210 |
Recommended max power at mpp[kW] | 55 | 75 | 90 | 110 |
Alternate AC generator | ||||
Input voltage | 380VAV(±15%),Three Phase | |||
Max amps(RMS)[A] | 113 | 157 | 180 | 214 |
Power and va capability [kVA] | 85 | 114 | 134 | 160 |
Output data | ||||
Rated output power[kW] | 55 | 75 | 93 | 110 |
Rated output voltage | 380VAC,Three Phase | |||
Max amps(RMS)[A] | 112 | 150 | 176 | 210 |
Output frequency | 0-50Hz/60Hz | |||
Pump system configuration parameters | ||||
Recommended solar panel power(KW) | 53-57 | 73-80 | 87-95 | 98-115 |
Solar panel connection | 400W*147P*30V 21series 7 parallel |
400W*200P*30V 20 series 10 parallel |
400W*240P*30V 20 series 12 parallel |
400W*280P*30V 20 series 4 parallel |
Applicable pump (kW) | 55 | 75 | 90 | 110 |
Pump motorvoltage(V) | 3PH 380V |