[Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
[Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

[Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
Picture
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker
  • [Copy] YCB6HLN-63 RCBO Electronic residual current circuit breaker

[Copy] YCB6HLN-63 RCBO Electronic residual curr...

General
1.Protetion against overloadand shortdrcuitourrents
2.Protection against the effects of sinusoidal altematingearth fault ourments
3.Protection against indrectcontacts and additional protertion against drectcontacts
4.Protectionagainst fire hazard caused byinsulationfaults
5.Used in reidential bulding
6.Acordngto the typeof instantaneous releasedassified as follows :type B3-5in,typeCβ-10)In,type D(10-20)ln

Contact Us

Product Details

未标题-1

General

1. Protection against overload and short-circuit currents

2. Protection against the effects of sinusoidal alternating earth fault currents

3. Protection against indirect contacts and additional protection against direct contacts.

4. Protection against fire hazard caused by insulation faults

5. Used in residential building

6. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln, type D(10-20)ln

Release

Type Test current Tripping time Expected result
B,C,D 1.13In t≤1h(In≤63A) Not tripping
1.13In t≤2h(In>63A)
B,C,D 1.45In t<1h(In≤63A) Tripping
1.45In t<2h(In>63A)
B,C,D 2.55In 1s<t<60s(In≤32A) Tripping
2.55In 1s<t<120s(In>32A)

 

Type Test current Tripping time Expected result
B 3In t≤0.1s Not tripping
C 5In t≤0.1s
D 10In t≤0.1s
B 5In t<0.1s Tripping
C 10In t<0.1s
D 20In t<0.1s

Curve

未标题-1

Specifications

Type Standard IEC/EN 61009-1
Electrical
features
Poles P 1P+N
Type(wave form of the earth leakage sensed) AC
Thermo-magnetic release characteristic B, C, D
Rated current In A 6, 10, 16, 20, 25, 32, 40, 50, 63
Rated voltage Ue V 230
Rated sensitivity lΔn A 0.03, 0.05, 0.1
Rated residual making and A 500(In≤40A) 630(In>40A)
breaking capacity lΔm
Rated short-circuit capacity lcn A 4500
Break time under lΔn s ≤0.1
Rated frequency Hz 50/60
Rated impulse withstand voltage(1.2/50)Uimp V 4000
Dielectric test voltage at ind.Freq.for 1min kV 2
Insulation voltage Ui V 500
Pollution degree 2
Mechanical features Electrical life t 4000
Mechanical life t 10000
Contact position indicator Yes
Protection degree IP20
Ambient temperature(with daily average≤35℃) -5~+40
Storage temperature -25~+70
Installation Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable mm² 25
AWG 3月18日
Terminal size top/bottom for busbar mm² 25
AWG 3月18日
Tightening torque N*m 2
In-Ibs 18
Mounting On DIN rail EN60715(35mm)by means of fast clip device
Connection From top

Overall and mounting dimensions(mm)