CJX2s-M AC Contactor switch ac unit replacement cost
CJX2s-M AC Contactor switch ac unit replacement cost
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

CJX2s-M AC Contactor switch ac unit replacement cost
Picture
Video
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
  • CJX2s-M AC Contactor switch ac unit replacement cost
CJX2s-M AC Contactor switch ac unit replacement cost Featured Image

CJX2s-M AC Contactor switch ac unit replacement...

Product Overview

CJX2s-M series AC Contactor with novel appearance and compact structure is suitable for using starting & controlling the AC motor frequently, switching on and off the circuit at a long distance. It is used in combination with thermal relay to compose a magnetic motor starter.

Standard: IEC 60947-1, IEC 60947-4-1.

Contact Us

Product Details

Responsive 3D Model

Product Overview

CJX2s-M series AC Contactor with novel appearance and compact structure is suitable for using starting & controlling the AC motor frequently, switching on and off the circuit at a long distance. It is used in combination with thermal relay to compose a magnetic motor starter.

Standard: IEC 60947-1, IEC 60947-4-1.

Model and Meaning

Specifications

Rated operation current(Ie): 6-16A;
Rated operation voltage(Ue): 220V~690V;
Rated insulation voltage: 690V;
Poles: 3P、4P;
Installation: Din rail and screw installation
Type Operating and Installation Conditions
Installation category III
Pollution level 3
Certification CE, CB, CCC, TUV
Protection degree Ip20
Ambient temperature limit of temperature: -35℃~+70℃,normal temperature: -5℃~+40℃,The average no more than +35℃ within 24 hours.If not in normal operating temperature range, please refer to "Instructions for abnormal environment"
Altitude ≤2000m
Ambient temperature The maximum temperature of 70 degrees, the air relative humidity not exceed 50%, under lowertemperature can allow for higher relative humidity.If the temperature is 20℃, the air relative humiditycould up to 90%, Special measures should betakenfor occasional condensation dueto humidity changes.
Installation position Inclination between installation surface and vertical surface should not exceed ±5°
Shock vibration Products should be installed and used withoutsignificant shake, shock and vibration place.

 

 Appearance

 
Type CJX2s-M06 CJX2s-M09 CJX2s-M12 CJX2s-M16
Poles 3P/4P
Rated insulation voltage(Ui) V 690
Rated operating voltage(Ue) V 380/400, 660/690
Rated thermal current(Ith) AC-1 20
Ratedoperation  current(Ie) AC-3,380/400V A 6 9 12 16
AC-3,660/690V A 3.8 4.9 4.9 4.9
AC-4,380/400V A 6 9 9 12
AC-4,660/690V A 3.8 4.9 4.9 4.9
Rated operational power(Pe) AC-3,380/400V kW 2.2 4 5.5 7.5
AC-3,660/690V kW 3 4 4 4
Mechanical life 10000 times 1200
Electrical life AC-3 120
AC-4 See electrical life curve
Frequencyof operation AC-3 times/ hour 1200
AC-4 300

 

Flexible wire 1 wire                    mm² 1…4
No terminal 2 wire mm² 1…4
Flexible wire 1 wire mm² 1…4
With terminals 2 wire mm² 1…2.5
Hard wire 1 wire mm² 1…4
No terminal 2 wire mm² 1…4
Fastening torque N·m 1.2
Coil
Rated control voltage(Us) 50Hz V 24、36、48、110、127、220、380、415
50/60Hz V 24、36、48、110、127、220、380、415
DC V 12、24、36、48、110、127、220
Allowed control   circuit voltage(Us) Operation V Installation inclination angle ±22.5°: 85%~110%Us; Installation inclination angle±5°: 70%~120%
Release(AC) V Installation inclination angle ±22.5°: 20%~75%Us;Installation inclination angle±5°: 20%~60%
Release(DC) V Installation inclination angle ±22.5°: 10%~75%Us;Installation inclination angle±5°: 10%~60%
Power consumption of coil Actuation VA 20-40
Keep VA 9.5

Consumption

W 1-3

 

Auxiliary contacts specification A 1NO/1NC
Rated thermal current (Ith) A 10
Rated operating voltage (Ue) AC V 380/400
DC V 220
Rated control capacit AC-15 VA Ue/Ie: AC380V/400V/ 1. 5A   It h: 10A
DC-13 W Ue/Ie: DC220V/0. 3A

Overall and Mounting

Type Amax Bmax Cmax Dmax a b Φ
CJX2s-M06-M16 45.5 59 58 94 35±0.35 50±0.48 4.2

CJX2s-M06/Z-M16/Z

45.5 59 70 106 35±0.35 50±0.48 4.2

Type Amax Bmax Cmax Dmax a b Φ
CJX2s-M06/N-M16/N 91 59 58 94 80±0.35 50±0.48 4.2
CJX2s-M06/Z/N-M16/Z/N 91 59 70 106 35±0.35 50±0.48 4.2

 

CJX2s-M AC Contactor selection table

Motor power kW Maximum operation current A Number of contacts contained in the contactor body  Contactor model
380V/400V 660V/690V (AC-3 380V/400V) NO NC
2.2 3 6 1 0 CJX2s-M0610
2.2 3 6 0 1 CJX2s-M0601
2.2 3 6 0 0 CJX2s-M0604
2.2 3 6 0 0 CJX2s-M0608
4 4 9 1 0 CJX2s-M0910
4 4 9 0 1 CJX2s-M0901
4 4 9 0 0 CJX2s-M0904
4 4 9 0 0 CJX2s-M0908
5.5 4 12 1 0 CJX2s-M1210
5.5 4 12 0 1 CJX2s-M1201
5.5 4 12 0 0 CJX2s-M1204
5.5 4 12 0 0 CJX2s-M1208
7.5 4 16 1 0 CJX2s-M1610
7.5 4 16 0 1 CJX2s-M1601
7.5 4 16 0 0 CJX2s-M1604
7.5 4 16 0 0 CJX2s-M1608

CJX2s-MAC Contactor Coil voltage specication table

AC(V) 50Hz 24 36 48 110 127 220 380 415
AC(V) 60Hz 24 36 48 110 127 220 380 415
AC(V) 50/60Hz 24 36 48 110 127 220 380 415
DC(V) 12 24 36 48 110 127 220 -

Instructions for use of correction factors in high altitude areas

Altitude (m) 2000 3000 4000
Rated impulse withstand voltage correction factor 1 0.88 0.78
Rated operation current correction factor 1 0.92

Instructions for use under abnormal ambient temperature

Ambient temperature (℃) 55 60 65 70
Correction factor 1 0.93 0.875 0.75