CJX2s AC three poles Contactor for ac
CJX2s AC three poles Contactor for ac
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

CJX2s AC three poles Contactor for ac
Picture
Video
  • CJX2s AC three poles Contactor for ac
  • CJX2s AC three poles Contactor for ac
  • CJX2s AC three poles Contactor for ac
  • CJX2s AC three poles Contactor for ac
  • CJX2s AC three poles Contactor for ac
  • CJX2s AC three poles Contactor for ac
  • CJX2s AC three poles Contactor for ac
  • CJX2s AC three poles Contactor for ac
  • CJX2s AC three poles Contactor for ac
  • CJX2s AC three poles Contactor for ac
CJX2s AC three poles Contactor for ac Featured Image

CJX2s AC three poles Contactor for ac

Product Overview
CJX2s series AC Contactor with novel appearance and compact structure is suitablefor using starting &controlling the AC motor frequently,switching on and off thecircuitat a long distance.It is used in combinationwith thermal relay to compose amagneticmotor starter
StandardIEC60947-1,IEC 60947-4-1.

Contact Us

Product Details

cjx2s-product-description1
cjx2s-product-description2
cjx2s-product-description3
cjx2s-product-description4

Product Overview

CJX2s series AC Contactor with novel appearance and compact structure is suitable for using starting & controlling the AC motor frequently, switching on and off the circuit at a long distance. It is used in combination with thermal relay to compose a magnetic motor starter.
Standard: IEC 60947-1, IEC 60947-4-1.

Specifications

Rated operation current(Ie): 9-95A;
Rated operation voltage(Ue): 220V~690V;
Rated insulation voltage: 690V; Poles: 3P;
Installation: Din rail and screw installation.

Operating and Installation Conditions

Type Operating and Installation Conditions
Installation category III
Pollution level 3
Protection degree CJX2s-09~38: IP20; CJX2s-40~95: IP10
Ambient temperature limit of temperature: -35℃~+70℃,normal temperature: -5℃~+40℃,The average no more than +35℃ within 24 hours.
Altitude ≤2000m
Ambient temperature The maximum temperature is 70 degrees, the relative humidity of the air does not exceed 50%, and the temperature below 50% can allow higher relative humidity. If the temperature is 20℃, the air relative  humidity could up to 90%, Special measures should betaken for occasional condensation due to humidity changes.
Installation position Inclination between installation surface and vertical surface should not exceed ±5°
Shock vibration Products should be installed and used without significant shake, shock and vibration.

Overall and Mounting

CJX2s-09~38

cjx2s-product-description7

CJX2s-40~95

cjx2s-product-description8
F4-D, LA2-D, LA3-D Contact Block
LX1-D Coil
Derived Products When The Contactor is Assembled With Following Accessory Module
F4-D, LA2-D, LA3-D Contact Block

cjx2s-product-description10

LX1-D Coil

Derived Products When The Contactor is Assembled With Following Accessory Module

Specifications

Appearance        
Type CJX2s-09 CJX2s-12 CJX2s-18 CJX2s-25 CJX2s-32 CJX2s-38 CJX2s-40 CJX2s-50 CJX2s-65 CJX2s-80 CJX2s-95
Main circuit characteristic
Poles 3P
Rated insulation voltage(Ui) V 690
Rated operating voltage(Ue) V 380/400, 660/690
Rated thermal current(Ith) ,AC-1 20 20 32 40 50 50 50 60 80 125 125
Rated
operation
current(Ie)
AC-3,380/400V A 9 12 18 25 32 38 40 50 65 80 95
AC-3,660/690V A 6.6 8.9 12 18 22 22 34 39 42 49 49
AC-4,380/400V A 3.5 5 7.7 8.5 12 14 18.5 24 28 37 44
AC-4,660/690V A 1.5 2 3.8 4.4 7.5 8.9 9 12 14 17.3 21.3
Rated
operational
power(Pe)
AC-3,380/400V kW 4 5.5 7.5 11 15 18.5 18.5 22 30 37 45
AC-3,660/690V kW 5.5 7.5 10 15 18.5 18.5 30 33 37 45 45
AC-4,380/400V kW 1.5 2.2 3.3 4 5.4 5.5 7.5 11 15 18.5 22
AC-4,660/690V kW 1.1 1.5 3 3.7 5.5 6 7.5 10 11 15 18.5
Mechanical life 10000
times
1200 1000 900 650
Electrical life AC-3 110 90 65
AC-4 22 22 17 11
Frequency
of operation
AC-3 times/
hour
1200 600
AC-4 300 300
Connecting capability of main circuit terminal
Flexible wire 1 wire                   mm² 1…4 1.5…6 2.5…25 4…50
No terminal 2 wire mm² 1…4 1.5…6 2.5…16 4…25
Flexible wire 1 wire mm² 1…4 1…6 2.5…25 4…50
With terminals 2 wire mm² 1…2.5 1…4 2.5…10 4…16
Hard wire 1 wire mm² 1…4 1.5…6 1.5…10 2.5…25 4…50
No terminal 2 wire mm² 1…4 1.5… 2.5…10 4…25
Fastening torque N·m 1.2 1.8 5 9
Coil
Rated control
voltage(Us)
50Hz V 24、36、48、110、127、220/230、240、380/400、415、440
50/60Hz V 24、36、48、110、127、220/230、240、380/400、415、440
Allowed control
circuit voltage(Us)
Operation V Installation inclination angle ±22.5°: 85%~110%Us;   Installation inclination angle±5°: 70%~120%
Release V Installation inclination angle ±22.5°: 20%~75%Us;Installation inclination angle±5°: 20%~65%
Power
consumption
of coil
Actuation VA 60 70 200 200
Keep VA 6-9.5 6-9.5 15-20 15-20
Consumption W 1-3 1-3 6-10 6-10
Auxiliary contacts
Auxiliary contacts specification A 11
Rated thermal current (Ith) A 10
Rated operating
voltage (Ue)
AC V 380
DC V 220
Rated control
capacity
AC-15 VA 360
DC-13 W 33
Certification                                                                                                                            CE, TUV, CB
 Type Amax Bmax Cmax a b c d e f
CJX2s-09, 12, 18 74.5 45.5 85.5 35 50/60 - - - -
CJX2s-25, 32, 38 83 56.5 97 40 50/70 - - - -
CJX2s-40, 50, 65 127.5 74.5 117 - - 105 40 100/110 59
CJX2s-80, 95 127.5 85.5 125.5 - - 105 40 100/110 67
Write your message here and send it to us

Related Products

  • Cino
  • Cino2025-03-24 23:56:52
    Hello, I am ‌‌Cino, welcome to CNC Electric. How can i help you?

Ctrl+Enter Wrap,Enter Send

  • FAQ
Please leave your contact information and chat
Hello, I am ‌‌Cino, welcome to CNC Electric. How can i help you?
Chat Now
Chat Now