Product Overview
Product Details
Data Download
Related Products
Cj19i contactor for capacitor switching (hereinafter called contactor)is suitable for the circuit of AC 50Hz/60Hz with rated voltage upto690V.It is mainly used to add low voltage reactive power compensation equipment or cut off low voltage parallel capacitor.
The contactor is equipped with a device to suppress the inrush current, which can effectively reduce the impact of the making inrush current on the capacitor and suppress the over-voltage when the capacitor is cut off. Standard:IEC/EN 60947-4-1.
Contact Us
CJ19i
CJ19i
Gj19s
General
Cj19i contactor for capacitor switching (hereinafter called contactor)is suitable for the circuit of AC 50Hz/60Hz with rated voltage up to 690V.It is mainly used to add low voltage reactive power compensation equipment or cut off low voltage parallel capacitor.
The contactor is equipped with a device to suppress the inrush current, which can effectively reduce the impact of the making inrush current on the capacitor and suppress the over-voltage when the capacitor is cut off. Standard:IEC/EN 60947-4-1.
Operating Conditions
o Ambient temperature:-5℃~+40℃ the average during 24 hours should not
o Atmosphere conditions: At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher relative humidity is allowable under lower temperature. For example, RH Could be 90% at +20℃, special measures should be taken for occurrence of condensation;
o pollutiondegree: 3
o Installation category: Ill
o Installation conditions: the inclination between installation plane and vertical plane is within ±5"
o Impact and shake: the products should locate in the places where there are no obvious impactand shake.
Technical Data
Model |
CJ19i-25 CJ19s-25 |
CJ19i-32 CJ19s-32 |
CJ19i-43 CJ19s-43 |
CJ19i-63 CJ19s-63 |
CJ19i-95 CJ19s-95 |
CJ19i-115 CJ19s-115 |
||
Main circuit features |
|
|||||||
Ratedoperatingvoltage(ue) |
V |
380/400 |
||||||
Rated isolation voltage(ui) |
V |
|
||||||
Rated current of controllable capacitor(In) |
|
A |
|
|
|
43 |
72 |
87 |
Rated capacityof controllable capacitor(Qn) |
|
kvar |
|
|
|
|
22.5 |
35 |
|
kvar |
|
|
|
|
45 |
|
|
Rated conventional heating current(lth) |
A |
25 |
32 |
43 |
|
|
|
|
Restrained surge capacity |
A |
≤35In |
≤55In |
|||||
Mechanical durability |
104 times |
|
||||||
Electrical durability |
|
104 times |
|
|
||||
operating
|
AC-6b400v times/h |
|
|
|||||
|
|
|||||||
controlled power
|
|
V |
1 10, 220, 380 |
|||||
operating
|
operation
|
V |
85%~110%us when instal l inclinatio n angl ei s+22.5"; 70%~120%us when instal l inclination angl ei s±5"; |
|||||
|
V |
20%~75%us when install inclination angle is +22.5"; 20%~65%us when install inclination angle is5"; |
||||||
Auxiliary contactfeatures |
|
|||||||
Number of auxiliarycontact |
12,21 |
|||||||
Rated conventional heating current(lth) |
A |
|
||||||
can be connected to |
6vx1 0mA |
Model |
Overall Dimensions |
Mounting Dimentsions |
||||
Amax |
Bmax |
Cmax |
Dmax |
Emax |
Fmax |
|
CJ19i(CJ19S)-25 |
176 |
45.5 |
122 |
74.5 |
35 |
50/60 |
CJ19i(CJ19S)-32 |
180 |
56.5 |
132 |
83 |
40 |
50/60 |
CJ19i(CJ19S)-43 |
180 |
56.5 |
132 |
83 |
40 |
50/60 |
CJ19i(CJ19S)-63 |
190 |
74.5 |
154 |
127.5 |
59 |
100/1 10 |
CJ19i(CJ19S)-95 |
190 |
85.5 |
160 |
127.5 |
67 |
100/1 10 |
CJ19i(CJ19S)-115 |
190 |
85.5 |
160 |
127.5 |
67 |
100/1 10 |