Product Overview
Product Details
Data Download
Related Products
Contact Us
Overall and mounting dimensions(mm)
Rated insulation voltage Ui: AC380V
Rated control voltage: AC110V, AC220V, AC380V
Usage category: Ue: AC110V/AC220V/AC380V; Ie: 6.5 A/ 3 A/ 1.9 A; Ith: 10 a; Ac-15
Protection degree: IP20
Pollution degree: 3
Load power: resistive load: 6kW; Inductive load: 1.8KW; Motor load: 1.2KW; Lamp load: 0.9KW
Wiring for direct control mode:
direct control mode can be used for electrical apparatus which is single-phase phase power supply and its power consumption doesn’t exceed
rated value of this switch.See Figure 1 for wiring method;
Wiring for single-phase dilatancy mode:
it is required a AC contactor with larger capacity than electrical apparatus power consumption for dilatancy when the controlled electrical apparatus
is single-phase power supply, whereas its power consumption exceeds rated value of this switch.
See Figure 2 for wiring method;
wiring for three-phase operation mode:
if the controlled electrical apparatus is three-phase power supply, it is required toexternally connect three-phase AC contactor.
See Figure 3 for wiring, control contactor @ AC220V coil voltage,50Hz;
See Figure 4 for wiring, control contactor @ AC 380V coil voltage,50Hz