Produkoorsig
Produkbesonderhede
Data aflaai
Verwante produkte
Kontak ons
Produksnaam | Skulpraam | Breekkapasiteit | PV DC | Aantal pale | Gegradeerde stroom | Bedryfspanning |
YCB8S | 63 | H | PVN | 2P | 20A | DC600 |
YCB8S | 63 | Standaard: 6KA H: 10ka | PVN: fotovoltaïese DC nie-polariteit | 1P 2P 3P 4P | 1A 2A 3A 4A 6A 10a 16a 20A 25a 32A 40A 50A 63a | DC300 DC600 DC900 DC1200 |
Aantal pale | 1P | 2P | 3P | 4P |
Gegradeerde werkspanning UE (V) | DC300 | DC600 | DC900 | DC1200 |
Gegradeerde isolasingspanning UI (V) | DC300 | DC600 | DC900 | DC1200 |
Gegradeerde impuls Weerstaan spanning Uimp (KV) | 6 | |||
Gegradeerde raamstroom (a) | 63 | |||
Gegradeerde stroom in (a) | 1,2,3,4,6,10,16,20,25,32,40,50,63 | |||
Ultieme kortsluiting van die breekkapasiteit ICU (KA) | Standaard: 6; h: 10 | |||
Onmiddellike trippende kenmerk | B, C, K | |||
Service Life (Times) | Meganiese 20000, elektriese lewe 1500 | |||
Beskermingsgraad | IP20 | |||
Omgewingstemperatuur vir gebruik | -25 ℃ ~+40 ℃ | |||
Hoogte | ≤2000 m | |||
Bedradingvermoë (mm²) | 25 | |||
Konneksie | Beide inkomende lyne van die boonste is aanvaarbaar | |||
Gebruik kategorie | A | |||
Standaard | IEC60947-2 |
Gegradeerde stroom (A) | Oorlading van die kenmerke | Onmiddellike tripping Eienskappe (A) | |
1.05in het ooreengekom nie Tripping Time H (Cold State) | 1.30 ln het ooreengekom dat die tyd H (warm staat) | ||
In ≤63 | 1 | 1 | B (4in ± 20%) C (8ln ± 20%) K (10in ± 20%) |
In> 63 | 2 | 2 |
Gegradeerde stroom (a) omgewingstemperatuur wat ooreenstem met die nominale stroom (a) | ||||||||||||
In (a) | -25 ℃ | -20 ℃ | -10 ℃ | 0 ℃ | 10 ℃ | 20 ℃ | 30 ℃ | 35 ℃ | 40 ℃ | 50 ℃ | 60 ℃ | 75 ℃ |
6A | 10.12 | 9.77 | 9.03 | 8.26 | 7.49 | 6.75 | 6 | 5.59 | 5.19 | 4.75 | 4.62 | / |
10a | 17.41 | 16.75 | 15.41 | 14.04 | 12.71 | 11.35 | 10 | 9.09 | 8.21 | 7.9 | 8.7 | 7.86 |
16a | 21.72 | 21.15 | 20.15 | 19.12 | 18.08 | 17.04 | 16 | 15.49 | 15.1 | 14.38 | 13.52 | 12.75 |
20A | 25.86 | 25.79 | 24.61 | 23.47 | 22.32 | 21.16 | 20 | 19.43 | 18.83 | 18.58 | 17.1 | 16.3 |
25a | 32.41 | 31.74 | 30.37 | 28.98 | 27.69 | 26.35 | 25 | 24.33 | 23.65 | 23.3 | 24.7 | 23.8 |
32A | 44.83 | 43.62 | 41.29 | 38.96 | 36.67 | 34.33 | 32 | 30.83 | 29.67 | 30.7 | 30.8 | 30 |
40A | 50.34 | 49.35 | 47.51 | 45.62 | 43.73 | 41.87 | 40 | 39.04 | 38.11 | 38.6 | 36.2 | 35.8 |
50A | 63.79 | 62.48 | 59.99 | 57.48 | 54.98 | 52.5 | 50 | 48.76 | 47.48 | 47.1 | 47.5 | 46 |
63a | 80 | 78.46 | 75.38 | 72.28 | 69.17 | 66.09 | 63 | 61.46 | 59.93 | 55.6 | 53.8 | 52.4 |
Model | YCB8S-63 van | YCB8S-63 SD | YCB8S-63 MX | |
Aantal kontakte | 1no+1nc | 1no+1nc | / | |
Beheerspanning (VAC) | 110-415 48 12-24 | |||
Beheerspanning (V DC) | 110-415 48 12-24 | |||
Werkstroom van kontak | AC-12 UE/LE: AC415/3a DC-12 UE/LE: DC125/2A | / | ||
Shunt beheerspanning | Ue/le: AC: 220-415/ 0.5a AC/DC: 24-48/3 | |||
Breedte (mm) | 9 | 9 | 18 | |
Toepaslike omgewingstoestande en installasie | ||||
Bergingstemperatuur (C) | -40 ℃ ~+70 ℃ | |||
Berging humiditeit | Die relatiewe humiditeit is nie meer as 95%as by+25 ℃ | |||
Beskermingsgraad | Vlak 2 | |||
Beskermingsgraad | IP20 | |||
Installasie -omgewing | Plekke sonder beduidende vibrasie en impak | |||
Installasie -kategorie | Kategorie ⅱ, Kategorie ⅲ | |||
Installasie -metode | TH35-7.5/DIN35 Rail Installation | |||
Maksimum bedradingskapasiteit | 2,5 mm² | |||
Terminale wringkrag | 1n · m |